3 resultados para egg and first instar larva
em AMS Tesi di Laurea - Alm@DL - Università di Bologna
Resumo:
Transgenerational plasticity (TGP), a type of maternal effect, occurs when the environment experienced by one or both the parents prior to fertilization directly translates, without changing DNA sequences, into changes in offspring reaction norms. Evidence of such effects has been found in several traits throughout many phyla, and, although of great potential importance - especially in a time of rapid climate change - TGP in thermal growth physiology had never been demonstrated for vertebrates until the first experiment on thermal TGP in sheepshead minnows, who, given sufficient time, adaptively program their offspring for maximal egg viability and growth at the temperature experienced before fertilization. This study on sheepshead minnows from South Carolina and Connecticut investigates how population, parent temperature, and offspring temperature affect egg production, size, viability, larval survival and growth rates, whether these effects provide evidence of TGP, and whether and how they vary with length of exposure time (5, 12, 19, 26, 33 and 43 days) of the parents to the new experimental temperatures of either 26°C or 32°C. Several results are consistent with those obtained in the previous TGP study, which outline a sequence of events consisting of an initial adjustment period to the new temperatures, in which egg production decreases and no signs of TGP are present, followed by a shift to TGP (towards 26-33 days of exposure) in which parents start to produce more eggs which are better adapted to the new thermal environment. Other results present new information, such as signs of TGP in the parent temperature effect on egg sizes already around 20 days of exposure. The innovative idea of populations being able to adapt to rapidly shifting environments through non-genetic mechanisms such as TGP opens new possibilities of survival of species and will have important implications on ecology, physiology, and contemporary evolution.
Resumo:
Il rilevatore Probe for LUminosity MEasurement (PLUME) è un luminometro per l’esperimento LHCb al CERN. Fornirà misurazioni istantanee della luminosità per LHCb durante la Run 3 a LHC. L’obiettivo di questa tesi è di valutare, con dati simulati, le prestazioni attese di PLUME, come l’occupanza dei PMT che compongono il rivelatore, e riportare l’analisi dei primi dati ottenuti da PLUME durante uno scan di Van der Meer. In particolare, sono state ottenuti tre misure del valore della sezione d’urto, necessarie per tarare il rivelatore, ovvero σ1Da = (1.14 ± 0.11) mb, σ1Db = (1.13 ± 0.10) mb, σ2D = (1.20 ± 0.02) mb, dove i pedici 1D e 2D corrispondono a uno scan di Van der Meer unidimensionale e bidimensionale. Tutti i risultati sono in accordo tra loro.
Resumo:
From 2010, the Proton Radius has become one of the most interest value to determine. The first proof of not complete understanding of its internal structure was the measurement of the Lamb Shift using the muonic hydrogen, leading to a value 7σ lower. A new road so was open and the Proton Radius Puzzle epoch begun. FAMU Experiment is a project that tries to give an answer to this Puzzle implementing high precision experimental apparatus. The work of this thesis is based on the study, construction and first characterization of a new detection system. Thanks to the previous experiments and simulations, this apparatus is composed by 17 detectors positioned on a semicircular crown with the related electronic circuit. The detectors' characterization is based on the use of a LabView program controlling a digital potentiometer and on other two analog potentiometers, all three used to set the amplitude of each detector to a predefined value, around 1.2 V, set on the oscilloscope by which is possible to observe the signal. This is the requirement in order to have, in the final measurement, a single high peak given by the sum of all the signals coming from the detectors. Each signal has been acquired for almost half of an hour, but the entire circuit has been maintained active for more time to observe its capacity to work for longer periods. The principal results of this thesis are given by the spectra of 12 detectors and the corresponding values of Voltages, FWHM and Resolution. The outcomes of the acquisitions show also another expected behavior: the strong dependence of the detectors from the temperature, demonstrating that an its change causes fluctuations in the signal. In turn, these fluctuations will affect the spectrum, resulting in a shifting of the curve and a lower Resolution. On the other hand, a measurement performed in stable conditions will lead to accordance between the nominal and experimental measurements, as for the detectors 10, 11 and 12 of our system.