2 resultados para dry powder inhalers

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interactions between outdoor bronzes and the environment, which lead to bronze corrosion, require a better understanding in order to design effective conservation strategies in the Cultural Heritage field. In the present work, investigations on real patinas of the outdoor monument to Vittorio Bottego (Parma, Italy) and laboratory studies on accelerated corrosion testing of inhibited (by silane-based films, with and without ceria nanoparticles) and non-inhibited quaternary bronzes are reported and discussed. In particular, a wet&dry ageing method was used both for testing the efficiency of the inhibitor and for patinating bronze coupons before applying the inhibitor. A wide range of spectroscopic techniques has been used, for characterizing the core metal (SEM+EDS, XRF, AAS), the corroded surfaces (SEM+EDS, portable XRF, micro-Raman, ATR-IR, Py-GC-MS) and the ageing solutions (AAS). The main conclusions were: 1. The investigations on the Bottego monument confirmed the differentiation of the corrosion products as a function of the exposure geometry, already observed in previous works, further highlighting the need to take into account the different surface features when selecting conservation procedures such as the application of inhibitors (i.e. the relative Sn enrichment in unsheltered areas requires inhibitors which effectively interact not only with Cu but also with Sn). 2. The ageing (pre-patination) cycle on coupons was able to reproduce the relative Sn enrichment that actually happens in real patinated surfaces, making the bronze specimens representative of the real support for bronze inhibitors. 3. The non-toxic silane-based inhibitors display a good protective efficiency towards pre-patinated surfaces, differently from other widely used inhibitors such as benzotriazole (BTA) and its derivatives. 4. The 3-mercapto-propyl-trimethoxy-silane (PropS-SH) additivated with CeO2 nanoparticles generally offered a better corrosion protection than PropS-SH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dry limited amplitude vibrations flow-transition induced vibrations were experienced on a helically-filleted tube, in a previous study performed by Kleissl and Georgakis (2012). These vibrations have never been reported in previous studies. A deep study on the same inclined-yawed cable configuration has been performed, in order to investigate and further understand the nature of these vibrations. The investigation has been carried out through passive-dynamic wind tunnel tests in the Climatic Wind Tunnel at FORCE Technology, Kgs. Lyngby, Denmark. The results are carried out in terms of aerodynamic damping and peak to peak amplitude at different flow velocities and different boundary conditions. The latter are done by testing the model with and without the spray system installed in the wind tunnel cross section, in order to understand and evaluate the influence of the spray system on the start of the vibrations mechanism and on the flow turbulence. The gained experiences are finally presented for the use in future testing activities with the purpose of improving the performance of passive-dynamic tests.