8 resultados para dislocation substructure

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

10.00% 10.00%

Publicador:

Resumo:

E' stato considerato un High-Dislocation Density Light Emitting Diode (HDD LED)ed è stato analizzato l'andamento di corrente a varie temperature. Dai risultati ottenuti è stato possibile ricavare il coefficiente di Poole-Frenkel, e da esso risalire alla densità di dislocazioni del dispositivo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concern of this work is to present the characterization of blue emitting GaN-based LED structures by means of Atomic Force Microscopy. Here we show a comparison among the samples with different dislocation densities, in order to understand how the dislocations can affect the surface morphology. First of all we have described the current state of art of the LEDs in the present market. Thereafterwards we have mentioned in detail about the growth technique of LED structures and the methodology of the characterization employed in our thesis. Finally, we have presented the details of the results obtained on our samples studied, followed by discussions and conclusions. L'obiettivo di questa tesi é quello di presentare la caratterizzazione mediante Microscopia a Forza Atomica di strutture di LED a emissione di luce blu a base di nitruro di gallio (GaN). Viene presentato un confronto tra campioni con differente densità di dislocazioni, allo scopo di comprendere in che modo la presenza di dislocazioni influisce sulla morfologia della superficie. Innanzitutto, viene descritto il presente stato dell'arte dei LED. Successivamente, sono forniti i dettagli riguardanti la tecnica di crescita delle strutture dei LED e il metodo di caratterizzazione adottato. Infine, vengono mostrati e discussi i risultati ottenuti dallo studio dei campioni, seguiti dalle conclusioni.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Top quark studies play an important role in the physics program of the Large Hadron Collider (LHC). The energy and luminosity reached allow the acquisition of a large amount of data especially in kinematic regions never studied before. In this thesis is presented the measurement of the ttbar production differential cross section on data collected by ATLAS in 2012 in proton proton collisions at \sqrt{s} = 8 TeV, corresponding to an integrated luminosity of 20.3 fb^{−1}. The measurement is performed for ttbar events in the semileptonic channel where the hadronically decaying top quark has a transverse momentum above 300 GeV. The hadronic top quark decay is reconstructed as a single large radius jet and identified using jet substructure properties. The final differential cross section result has been compared with several theoretical distributions obtaining a discrepancy of about the 25% between data and predictions, depending on the MC generator. Furthermore the kinematic distributions of the ttbar production process are very sensitive to the choice of the parton distribution function (PDF) set used in the simulations and could provide constraints on gluons PDF. In particular in this thesis is performed a systematic study on the PDF of the protons, varying several PDF sets and checking which one better describes the experimental distributions. The boosted techniques applied in this measurement will be fundamental in the next data taking at \sqrt{s}=13 TeV when will be produced a large amount of heavy particles with high momentum.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the last years the number of shoulder arthroplasties has been increasing. Simultaneously the study of their shape, size and strength and the reasons that bring to a possible early explantation have not yet been examined in detail. The research carried out directly on explants is practically nonexistent, this means a poor understanding of the mechanisms leading the patient and so the surgeon, to their removal. The analysis of the mechanisms which are the cause of instability, dislocation, broken, fracture, etc, may lead to a change in the structure or design of the shoulder prostheses and lengthen the life of the implant in situ. The idea was to analyze 22 explants through three methods in order to find roughness, corrosion and surface wear. In the first method, the humeral heads and/or the glenospheres were examined with the interferometer, a machine that through electromagnetic waves gives information about the roughness of the surfaces under examination. The output of the device was a total profile containing both roughness and information on the waves (representing the spatial waves most characteristic on the surface). The most important value is called "roughness average" and brings the average value of the peaks found in the local defects of the surfaces. It was found that 42% of the prostheses had considerable peak values in the area where the damage was caused by the implant and not only by external events, such as possibly the surgeon's hand. One of the problems of interest in the use of metallic biomaterials is their resistance to corrosion. The clinical significance of the degradation of metal implants has been the purpose of the second method; the interaction between human body and metal components is critical to understand how and why they arrive to corrosion. The percentage of damage in the joints of the prosthetic components has been calculated via high resolution photos and the software ImageJ. The 40% and 50% of the area appeared to have scratches or multiple lines due to mechanical artifacts. The third method of analysis has been made through the use of electron microscopy to quantify the wear surface in polyethylene components. Different joint movements correspond to different mechanisms of damage, which were imprinted in the parts of polyethylene examined. The most affected area was located mainly in the side edges. The results could help the manufacturers to modify the design of the prostheses and thus reduce the number of explants. It could also help surgeons in choosing the model of the prosthesis to be implanted in the patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The revision hip arthroplasty is a surgical procedure, consisting in the reconstruction of the hip joint through the replacement of the damaged hip prosthesis. Several factors may give raise to the failure of the artificial device: aseptic loosening, infection and dislocation represent the principal causes of failure worldwide. The main effect is the raise of bone defects in the region closest to the prosthesis that weaken the bone structure for the biological fixation of the new artificial hip. For this reason bone reconstruction is necessary before the surgical revision operation. This work is born by the necessity to test the effects of bone reconstruction due to particular bone defects in the acetabulum, after the hip prosthesis revision. In order to perform biomechanical in vitro tests on hip prosthesis implanted in human pelvis or hemipelvis a practical definition of a reference frame for these kind of bone specimens is required. The aim of the current study is to create a repeatable protocol to align hemipelvic samples in the testing machine, that relies on a reference system based on anatomical landmarks on the human pelvis. In chapter 1 a general overview of the human pelvic bone is presented: anatomy, bone structure, loads and the principal devices for hip joint replacement. The purpose of chapters 2 is to identify the most common causes of the revision hip arthroplasty, analysing data from the most reliable orthopaedic registries in the world. Chapter 3 presents an overview of the most used classifications for acetabular bone defects and fractures and the most common techniques for acetabular and bone reconstruction. After a critical review of the scientific literature about reference frames for human pelvis, in chapter 4, the definition of a new reference frame is proposed. Based on this reference frame, the alignment protocol for the human hemipelvis is presented as well as the statistical analysis that confirm the good repeatability of the method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When the offshore oil and gas supplies exhaust, offshore platforms must be decommissioned and removed. The present thesis highlights the importance of evaluating the possibility of reuse of decommissioned offshore jacket platforms for offshore wind energy. In order to shift to the new structure, the topside must be removed from the substructure and a wind turbine can be installed in its place. The feasibility of this project was investigated using a finite element analysis software called Sesam. To study fatigue life in offshore structures, an exhaustive review of the background and state of the art was done. A finite element model was created by the means of Sesam and two different fatigue analysis approaches were applied and compared. In the end, an analysis methodology is suggested for the structural fatigue analysis of offshore wind turbine structures based on international standards, addressing the industry’s need to account for the combined effect of wind and hydrodynamic loads in these type of structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: La lussazione traumatica della rotula rappresenta il 2-3% delle lesioni riguardanti il ginocchio. È una condizione comune negli adolescenti e colpisce maggiormente il sesso femminile. Si associa spesso ad instabilità rotulea, alti tassi di ridislocazione, dolore, difficoltà nel ritorno alle attività di vita quotidiana e allo sport e artrosi dell’articolazione femoro-rotulea. Obiettivo: Lo scopo di questa Revisione Sistematica è confrontare i risultati di studi randomizzati controllati che esaminano l’efficacia di due tipi di trattamento, chirurgico e conservativo, rispetto a: funzionalità del ginocchio, tasso di ridislocazione, qualità di vita e ritorno allo sport nei pazienti affetti da un primo episodio di lussazione rotulea. Metodi: La ricerca è stata condotta sulle banche dati PubMed, Cochrane Library e PEDro. Sono stati selezionati RCT in lingua inglese senza imporre limiti temporali, che presentavano entrambi i trattamenti, chirurgico e conservativo, e un follow up di almeno due anni. I partecipanti dovevano essere affetti unicamente da un primo episodio di lussazione. La qualità metodologica degli articoli è stata valutata tramite la PEDro scale. Risultati: Otto articoli hanno soddisfatto i criteri di eleggibilità e sono stati inclusi nella Revisione. Il punteggio medio alla PEDro scale di 3.6/10 ha rivelato una scarsa qualità metodologica degli articoli. La gran parte degli studi ha rilevato una riduzione del tasso di ridislocazione con il trattamento chirurgico, mentre non c’è concordanza nell’affermare la sua superiorità per migliorare la funzionalità del ginocchio. Conclusioni: Gli studi inclusi non hanno mostrato una chiara efficacia di un trattamento rispetto all’altro, se non riguardo al tasso di ridislocazione, ma la loro scarsa qualità metodologica rende tali risultati inaffidabili. Pertanto, sono necessari studi di qualità superiore per determinare con maggior precisione l’efficacia comparativa dei due interventi.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gravitational lensing is a powerful tool to investigate the properties of the distribution of matter, be it barionic or dark. In this work we take advantage of Strong Gravitational Lensing to infer the properties of one of the galaxy-scale substructures that makes up the cluster MACSJ1206. It is relatively easy to model the morphology of the visible components of a galaxy, while the morphology of the dark matter distribution cannot be so easily constrained. Being sensitive to the whole mass, strong lensing provides a way to probe DM distribution, and this is the reason why it is the best tool to study the substructure. The goal of this work consists of performing an analysis of the substructure previously mentioned, an early type galaxy (ETG), by analyzing the highly magnified Einstein ring around it, in order to put stringent constraints on its matter distribution, that, for an ETG, is commonly well described by an isothermal profilele. This turns out to be interesting for three main different reasons. It is well known that galaxies in clusters are subject to interaction processes, both dynamic and hydrodynamic, that can significantly modify the distribution of matter within them. Therefore, finding a different profile from the one usually expected could be a sign that the galaxy has undergone processes that have changed its structure. Studying the mass distribution also means studying the dark matter component, which not only still presents great questions today, but which is also not obviously distributed in the same way as in an isolated galaxy. What emerges from the analysis is that the total mass distribution of the galaxy under examination turns out to have a slope much steeper than the isothermal usually expected.