15 resultados para Seismic microzonation
em AMS Tesi di Laurea - Alm@DL - Università di Bologna
Resumo:
Three structural typologies has been evaluated based on the nonlinear dynamic analysis (i.e. Newmark's methods for MDFs: average acceleration method with Modified Newton-Raphson iteration). Those structural typologies differ each other only for the infills presence and placement. In particular, with the term BARE FRAME: the model of the structure has two identical frames, arranged in parallel. This model constitutes the base for the generation of the other two typologies, through the addition of non-bearing walls. Whereas with the term INFILLED FRAME: the model is achieved by adding twelve infill panels, all placed in the same frame. Finally with the term PILOTIS: the model has been generated to represent structures where the first floor has no walls. Therefore the infills are positioned in only one frame in its three upper floors. All three models have been subjected to ten accelerograms using the software DRAIN 2000.
Resumo:
In this work seismic upgrading of existing masonry structures by means of hysteretic ADAS dampers is treated. ADAS are installed on external concrete walls, which are built parallel to the building, and then linked to the building's slab by means of steel rod connection system. In order to assess the effectiveness of the intervention, a parametric study considering variation of damper main features has been conducted. To this aim, the concepts of equivalent linear system (ELS) or equivalent viscous damping are deepen. Simplified equivalent linear model results are then checked respect results of the yielding structures. Two alternative displacement based methods for damper design are herein proposed. Both methods have been validated through non linear time history analyses with spectrum compatible accelerograms. Finally ADAS arrangement for the non conventional implementation is proposed.
Resumo:
Negli ultimi anni la ricerca ha fatto grandi passi avanti riguardo ai metodi di progetto e realizzazione delle strutture portanti degli edifici, a tal punto da renderle fortemente sicure sotto tutti i punti di vista. La nuova frontiera della ricerca sta quindi virando su aspetti che non erano mai stati in primo piano finora: gli elementi non-strutturali. Considerati fino ad oggi semplicemente carico accessorio, ci si rende sempre più conto della loro capacità di influire sui comportamenti delle strutture e sulla sicurezza di chi le occupa. Da qui nasce l’esigenza di questo grande progetto chiamato BNCs (Building Non-structural Component System), ideato dall’Università della California - San Diego e sponsorizzato dalle maggiori industrie impegnate nel campo delle costruzioni. Questo progetto, a cui ho preso parte, ha effettuato test su tavola vibrante di un edificio di cinque piani in scala reale, completamente arredato ed allestito dei più svariati elementi non-strutturali. Lo scopo della tesi in questione, ovviamente, riguarda l’identificazione strutturale e la verifica della sicurezza di uno di questi elementi non-strutturali: precisamente la torre di raffreddamento posta sul tetto dell’edificio (del peso di circa 3 tonnellate). Partendo da una verifica delle regole e calcoli di progetto, si è passato ad una fase di test sismici ed ispezioni post-test della torre stessa, infine tramite l’analisi dei dati raccolti durante i test e si è arrivati alla stesura di conclusioni.
Resumo:
The thesis moves from the need of understanding how a historical building would behave in case of earthquake and this purpose is strongly linked to the fact that the majority of Italian structures are old ones placed in seismic sites. Primarily an architectural and chronological research is provided in order to figure out how the building has developed in time; then, after the reconstruction of the skeleton of the analyzed element (“Villa i Bossi” in Gragnone, AR), a virtual model is created such that the main walls and sections are tested according to the magnitude of expected seismic events within the reference area. This approach is basically aimed at verifying the structure’s reliability as composed by single units; the latter are treated individually in order to find out all the main critical points where rehabilitation might be needed. Finally the most harmful sections are studied in detail and proper strengthening is advised according to the current know-how.
Resumo:
Negli ultimi anni sono state sviluppate varie soluzioni tecniche per la progettazione sismica di strutture. Questa ricerca sviluppa un metodo di confronto basato sull'analisi di costi di costruzione e danni causati dal sisma. Il metodo viene applicato al caso di studio della scuola di Bisignano (CO, Italia). L'edificio è stato progettato conformemente alle NTC 2008 con approccio tradizionale e combinando il contributo di dissipatori viscosi e dissipazione isteretica. Le strutture vengono poi analizzate sotto diverse condizioni sismiche al fine di calcolare i costi di riparazione attesi e comprendere quale soluzione tecnica risulti più economicamente vantaggiosa a parità di azione sismica di progetto.
Resumo:
Seismic assessment and seismic strengthening are the key issues need to be figured out during the process of protection and reusing of historical buildings. In this thesis the seismic behaviors of the hinged steel structure, a typical structure of historical buildings, i.e. hinged steel frames in Shanghai, China, were studied based on experimental investigations and theoretic analysis. How the non-structural members worked with the steel frames was analyzed thoroughly. Firstly, two 1/4 scale hinged steel frames were constructed based on the structural system of Bund 18, a historical building in Shanghai: M1 model without infill walls, M2 model with infill walls, and tested under the horizontal cyclic loads to investigate their seismic behavior. The Shaking Table Test and its results indicated that the seismic behavior of the hinged steel frames could be improved significantly with the help of non-structural members, i.e., surrounding elements outside the hinged steel frames and infilled walls. To specify, the columns are covered with bricks, they consist of I shape formed steel sections and steel plates, which are clenched together. The steel beams are connected to the steel column by steel angle, thus the structure should be considered as a hinged frame. And the infilled wall acted as a compression diagonal strut to withstand the horizontal load, therefore, the seismic capacity and stiffness of the hinged steel frames with infilled walls could be estimated by using the equivalent compression diagonal strut model. A SAP model has been constructed with the objective to perform a dynamic nonlinear analysis. The obtained results were compared with the results obtained from Shaking Table Test. The Test Results have validated that the influence of infill walls on seismic behavior can be estimated by using the equivalent diagonal strut model.
Resumo:
We explore the thesis that tall structures can be protected by means of seismic metamaterials. Seismic metamaterials can be built as some elements are created over soil layer with different shapes, dimensions, patterns and from different materials. Resonances in these elements are acting as locally resonant metamaterials for Rayleigh surface waves in the geophysics context. Analytically we proved that if we put infinite chain of SDOF resonator over the soil layer as an elastic, homogeneous and isotropic material, vertical component of Rayleigh wave, longitudinal resonance of oscillators will couple with each other, they would create a Rayleigh bandgap frequency, and wave will experience attenuation before it reaches the structure. As it is impossible to use infinite chain of resonators over soil layer, we considered finite number of resonators throughout our simulations. Analytical work is interpreted using finite element simulations that demonstrates the observed attenuation is due to bandgaps when oscillators are arranged at sub-wavelength scale with respect to the incident Rayleigh wave. For wavelength less than 5 meters, the resulting bandgaps are remarkably large and strongly attenuating when impedance of oscillators matches impedance of soil. Since longitudinal resonance of SDOF resonator are proportional to its length inversely, a formed array of resonators that attenuates Rayleigh waves at frequency ≤10 Hz could be designed starting from vertical pillars coupled to the ground. Optimum number of vertical pillars and their interval spacing called effective area of resonators are investigated. For 10 pillars with effective area of 1 meter and resonance frequency of 4.9 Hz, bandgap frequency causes attenuation and a sinusoidal impulsive force illustrate wave steering down phenomena. Simulation results proved analytical findings of this work.
Resumo:
Many buildings constructed during the middle of the 20th century were constructed with criteria that fall short of current requirements. Although shortcomings are possible in all aspects of the design, the inadequacies in terms of seismic design present a more pressing issue to human life. This risk has been seen in various earthquakes that have struck Italy recently, and subsequently, the codes have been altered to account for this underestimated danger. Structures built after these changes remain at risk and must be retrofitted depending on their use. This report centers around the Giovanni Michelucci Institute of Mathematics at the University of Bologna and the work required to modify the building so that it can withstand 60% of the current design requirements. The goal of this particular report is to verify the previous reports written in Italian and present an accurate analysis along with intervention suggestions for this particular building. The work began with an investigation into the previous sources and work to find out how the structure had been interpreted. After understanding the building, corrections were made where required, and the failing elements were organized graphically to more easily show where the building needed the most work. Once the critical zones were mapped, remediation techniques were tested on the top floor, and the modeling techniques and effects of the interventions were presented to assist in further work on the structure.