All the structures designed by engineers are vulnerable to natural disasters including floods and earthquakes. The energy released during strong ground motions should be dissipated by structural elements. Before 1990’s, this energy was expected to be dissipated through the beams and columns which at the same time were a part of gravity-load-resisting system. However, the main disadvantage of this idea was that gravity-resisting-frame was not repairable. Hence, during 1990’s, the idea of designing passive energy dissipation systems, including dampers, emerged. At the beginning, main problem was lack of guidelines for passive energy dissipation systems. Although till 2000 many guidelines and procedures where published, yet most of them were based on complicated analysis which was not so convenient for engineers and practitioners. In order to solve this problem recently some alternative design methods are proposed including 1. Lopez Garcia (2001) simple procedure for optimal damper configuration in MDOF structures 2. Christopoulos and Filiatrault (2006) trial and error procedure 3. Silvestri et al. (2010) Five-Step Method. 4. Palermo et al. (2015) Direct Five-Step Method. 5. Palermo et al. (2016) Simplified Equivalent Static Analysis (ESA). In this study, effectiveness and differences between last three alternative methods have been evaluated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Three structural typologies has been evaluated based on the nonlinear dynamic analysis (i.e. Newmark's methods for MDFs: average acceleration method with Modified Newton-Raphson iteration). Those structural typologies differ each other only for the infills presence and placement. In particular, with the term BARE FRAME: the model of the structure has two identical frames, arranged in parallel. This model constitutes the base for the generation of the other two typologies, through the addition of non-bearing walls. Whereas with the term INFILLED FRAME: the model is achieved by adding twelve infill panels, all placed in the same frame. Finally with the term PILOTIS: the model has been generated to represent structures where the first floor has no walls. Therefore the infills are positioned in only one frame in its three upper floors. All three models have been subjected to ten accelerograms using the software DRAIN 2000.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Negli ultimi anni sono state sviluppate varie soluzioni tecniche per la progettazione sismica di strutture. Questa ricerca sviluppa un metodo di confronto basato sull'analisi di costi di costruzione e danni causati dal sisma. Il metodo viene applicato al caso di studio della scuola di Bisignano (CO, Italia). L'edificio è stato progettato conformemente alle NTC 2008 con approccio tradizionale e combinando il contributo di dissipatori viscosi e dissipazione isteretica. Le strutture vengono poi analizzate sotto diverse condizioni sismiche al fine di calcolare i costi di riparazione attesi e comprendere quale soluzione tecnica risulti più economicamente vantaggiosa a parità di azione sismica di progetto.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Seismic assessment and seismic strengthening are the key issues need to be figured out during the process of protection and reusing of historical buildings. In this thesis the seismic behaviors of the hinged steel structure, a typical structure of historical buildings, i.e. hinged steel frames in Shanghai, China, were studied based on experimental investigations and theoretic analysis. How the non-structural members worked with the steel frames was analyzed thoroughly. Firstly, two 1/4 scale hinged steel frames were constructed based on the structural system of Bund 18, a historical building in Shanghai: M1 model without infill walls, M2 model with infill walls, and tested under the horizontal cyclic loads to investigate their seismic behavior. The Shaking Table Test and its results indicated that the seismic behavior of the hinged steel frames could be improved significantly with the help of non-structural members, i.e., surrounding elements outside the hinged steel frames and infilled walls. To specify, the columns are covered with bricks, they consist of I shape formed steel sections and steel plates, which are clenched together. The steel beams are connected to the steel column by steel angle, thus the structure should be considered as a hinged frame. And the infilled wall acted as a compression diagonal strut to withstand the horizontal load, therefore, the seismic capacity and stiffness of the hinged steel frames with infilled walls could be estimated by using the equivalent compression diagonal strut model. A SAP model has been constructed with the objective to perform a dynamic nonlinear analysis. The obtained results were compared with the results obtained from Shaking Table Test. The Test Results have validated that the influence of infill walls on seismic behavior can be estimated by using the equivalent diagonal strut model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Many buildings constructed during the middle of the 20th century were constructed with criteria that fall short of current requirements. Although shortcomings are possible in all aspects of the design, the inadequacies in terms of seismic design present a more pressing issue to human life. This risk has been seen in various earthquakes that have struck Italy recently, and subsequently, the codes have been altered to account for this underestimated danger. Structures built after these changes remain at risk and must be retrofitted depending on their use. This report centers around the Giovanni Michelucci Institute of Mathematics at the University of Bologna and the work required to modify the building so that it can withstand 60% of the current design requirements. The goal of this particular report is to verify the previous reports written in Italian and present an accurate analysis along with intervention suggestions for this particular building. The work began with an investigation into the previous sources and work to find out how the structure had been interpreted. After understanding the building, corrections were made where required, and the failing elements were organized graphically to more easily show where the building needed the most work. Once the critical zones were mapped, remediation techniques were tested on the top floor, and the modeling techniques and effects of the interventions were presented to assist in further work on the structure.