3 resultados para S960 QC

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Determinazione del Documento Preliminare relativamente alle fasi di sintesi del QC, di individuazione degli obiettivi, e di definizione delle misure da adottare per il risanamento della risorsa idrica nel territorio ferrarese.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the support of data collected by CPT tests on-site, in this report, we try to estimate the liquefaction potential in soils at high risk, due to the presence of sandy horizons. We began by acquiring some basic theory about the topic with the help of texts, articles and documents found in the web. The notions found here were consequently applied to two concrete case studies. 
In the first part of the work, the phenomenon of liquefaction is analyzed at a theoretical level. Moreover, we want to find out the trigger factors and the possible side effects whenever this event occurs.
In the second part of the work, we re-elaborated the data concerning tip resistance (qc) and resistance to friction side (fs) obtained by CPT tests taken in proximity of San Carlo (FE) and Isola Serafini (PC). We particularly chose to go through this specific process to estimate the land liquefaction potential. 
The main purpose is finally to compare the results of both tests and to comment on them.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

According to the SM, while Lepton Flavour Violation is allowed in the neutral sector, Charged Lepton Flavour Violation (CLFV) processes are forbidden. The Mu2e Experiment at Fermilab will search for the CLFV process of neutrinoless conversion of a muon into an electron within the field of an Al nucleus. The Mu2e detectors and its state-of-the-art superconducting magnetic system are presented, with special focus put to the electromagnetic crystal calorimeter. The calorimeter is composed by two annular disks, each one hosting pure CsI crystals read-out by custom silicon photomultipliers (SiPMs). The SiPMs are amplified by custom electronics (FEE) and are glued to copper holders in group of 2 SiPMs and 2 FEE boards thus forming a crystal Readout Unit. These Readout Units are being tested at the Quality Control (QC) Station, whose design, realization and operations are presented in this work. The QC Station allows to determine the gain, the response and the photon detection efficiency of each unit and to evaluate the dependence of these parameters from the supply voltage and temperature. The station is powered by two remotely-controlled power supplies and monitored thanks to a Slow Control system which is also illustrated in this work. In this thesis, we also demonstrated that the calorimeter can perform its own measurement of the Mu2e normalization factor, i.e. the counting of the 1.8 MeV photon line produced in nuclear muon captures. A specific calorimeter sub-system called CAPHRI, composed by four LYSO crystals with SiPM readout, has been designed and tested. We simulated the capability of this system on performing this task showing that it can get a faster and more reliable measurement of the muon capture rates with respect to the current Mu2e detector dedicated to this measurement. The characterization of energy resolution and response uniformity of the four procured LYSO crystals are llustrated.