This thesis studies the state-of-the-art of phasor measurement units (PMUs) as well as their metrological requirements stated in the IEEE C37.118.1 and C37.118.2 Standards for guaranteeing correct measurement performances. Communication systems among PMUs and their possible applicability in the field of power quality (PQ) assessment are also investigated. This preliminary study is followed by an analysis of the working principle of real-time (RT) simulators and the importance of hardware-in-the-loop (HIL) implementation, examining the possible case studies specific for PMUs, including compliance tests which are one of the most important parts. The core of the thesis is focused on the implementation of a PMU model in the IEEE 5-bus network in Simulink and in the validation of the results using OPAL RT-4510 as a real-time simulator. An initial check allows one to get an idea about the goodness of the results in Simulink, comparing the PMU data with respect to the load-flow steady-state information. In this part, accuracy indices are also calculated for both voltage and current synchrophasors. The following part consists in the implementation of the same code in OPAL-RT 4510 simulator, after which an initial analysis is carried out in a qualitative way in order to get a sense of the goodness of the outcomes. Finally, the confirmation of the results is based on an examination of the attained voltage and current synchrophasors and accuracy indices coming from Simulink models and from OPAL system, using a Matlab script. This work also proposes suggestions for an upcoming operation of PMUs in a more complex system as the Digital Twin (DT) in order to improve the performances of the already-existing protection devices of the distribution system operator (DSO) for a future enhancement of power systems reliability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the increase in load demand for various sectors, protection and safety of the network are key factors that have to be taken into consideration over the electric grid and distribution network. A phasor Measuring unit is an Intelligent electronics device that collects the data in the form of a real-time synchrophasor with a precise time tag using GPS (Global positioning system) and transfers the data to the grid command to monitor and assess the data. The measurements made by PMU have to be very precise to protect the relays and measuring equipment according to the IEEE 60255-118-1(2018). As a device PMU is very expensive to research and develop new functionalities there is a need to find an alternative to working with. Hence many open source virtual libraries are available to replicate the exact function of PMU in the virtual environment(Software) to continue the research on multiple objectives, providing the very least error results when verified. In this thesis, I executed performance and compliance verification of the virtual PMU which was developed using the I-DFT (Interpolated Discrete Fourier transforms) C-class algorithm in MATLAB. In this thesis, a test environment has been developed in MATLAB and tested the virtually developed PMU on both steady state and dynamic state for verifying the latest standard compliance(IEEE-60255-118-1).