3 resultados para Proton
em AMS Tesi di Laurea - Alm@DL - Università di Bologna
Resumo:
The multimodal biology activity of ergot alkaloids is known by humankind since middle ages. Synthetically modified ergot alkaloids are used for the treatment of various medical conditions. Despite the great progress in organic syntheses, the total synthesis of ergot alkaloids remains a great challenge due to the complexity of their polycyclic structure with multiple stereogenic centres. This project has developed a new domino reaction between indoles bearing a Michael acceptor at the 4 position and nitroethene, leading to potential ergot alkaloid precursors in highly enantioenriched form. The reaction was optimised and applied to a large variety of substrate with good results. Even if unfortunately all attempts to further modify the obtained polycyclic structure failed, it was found a reaction able to produce the diastereoisomer of the polycyclic product in excellent yields. The compounds synthetized were characterized by NMR and ESIMS analysis confirming the structure and their enantiomeric excess was determined by chiral stationary phase HPLC. The mechanism of the reaction was evaluated by DFT calculations, showing the formation of a key bicoordinated nitronate intermediate, and fully accounting for the results observed with all substrates. The relative and absolute configuration of the adducts were determined by a combination of NMR, ECD and computational methods.
Resumo:
La sezione d’urto totale adronica gioca un ruolo fondamentale nel programma di fisica di LHC. Un calcolo di questo parametro, fondamentale nell’ambito della teoria delle interazioni forti, non é possibile a causa dell’inapplicabilità dell’approccio perturbativo. Nonostante ciò, la sezione d’urto può essere stimata, o quanto meno le può essere dato un limite, grazie ad un certo numero di relazioni, come ad esempio il Teorema Ottico. In questo contesto, il detector ALFA (An Absolute Luminosity For ATLAS) sfrutta il Teorema Ottico per determinare la sezione d’urto totale misurando il rate di eventi elastici nella direzione forward. Un tale approccio richiede un metodo accurato di misura della luminosità in condizioni sperimentali difficoltose, caratterizzate da valori di luminosità istantanea inferiore fino a 7 ordini di grandezza rispetto alle normali condizioni di LHC. Lo scopo di questa tesi è la determinazione della luminosità integrata di due run ad alto β*, utilizzando diversi algoritmi di tipo Event-Counting dei detector BCM e LUCID. Particolare attenzione è stata riservata alla sottrazione del fondo e allo studio delle in- certezze sistematiche. I valori di luminosità integrata ottenuti sono L = 498.55 ± 0.31 (stat) ± 16.23 (sys) μb^(-1) and L = 21.93 ± 0.07 (stat) ± 0.79 (sys) μb^(-1), rispettivamente per i due run. Tali saranno forniti alla comunità di fisica che si occupa della misura delle sezioni d’urto protone-protone, elastica e totale. Nel Run II di LHC, la sezione d’urto totale protone-protone sarà stimata con un’energia nel centro di massa di 13 TeV per capire meglio la sua dipendenza dall’energia in un simile regime. Gli strumenti utilizzati e l’esperienza acquisita in questa tesi saranno fondamentali per questo scopo.
Resumo:
This thesis focuses on advanced reconstruction methods and Dual Energy (DE) Computed Tomography (CT) applications for proton therapy, aiming at improving patient positioning and investigating approaches to deal with metal artifacts. To tackle the first goal, an algorithm for post-processing input DE images has been developed. The outputs are tumor- and bone-canceled images, which help in recognising structures in patient body. We proved that positioning error is substantially reduced using contrast enhanced images, thus suggesting the potential of such application. If positioning plays a key role in the delivery, even more important is the quality of planning CT. For that, modern CT scanners offer possibility to tackle challenging cases, like treatment of tumors close to metal implants. Possible approaches for dealing with artifacts introduced by such rods have been investigated experimentally at Paul Scherrer Institut (Switzerland), simulating several treatment plans on an anthropomorphic phantom. In particular, we examined the cases in which none, manual or Iterative Metal Artifact Reduction (iMAR) algorithm were used to correct the artifacts, using both Filtered Back Projection and Sinogram Affirmed Iterative Reconstruction as image reconstruction techniques. Moreover, direct stopping power calculation from DE images with iMAR has also been considered as alternative approach. Delivered dose measured with Gafchromic EBT3 films was compared with the one calculated in Treatment Planning System. Residual positioning errors, daily machine dependent uncertainties and film quenching have been taken into account in the analyses. Although plans with multiple fields seemed more robust than single field, results showed in general better agreement between prescribed and delivered dose when using iMAR, especially if combined with DE approach. Thus, we proved the potential of these advanced algorithms in improving dosimetry for plans in presence of metal implants.