11 resultados para Power Engineering, Current Control, Hysteresis, Random Pulse Width Modulation (RPWM)

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The convergence of information technology and consumer electronics towards battery powered portable devices has increased the interest in high efficiency, low dissipation amplifiers. Class D amplifiers are the state of the art in low power consumption and high performance amplification. In this thesis we explore the possibility of exploiting nonlinearities introduced by the PWM modulation, by designing an optimized modulation law which scales its carrier frequency adaptively with the input signal's average power while preserving the SNR, thus reducing power consumption. This is achieved by means of a novel analytical model of the PWM output spectrum, which shows how interfering harmonics and their bandwidth affect the spectrum. This allows for frequency scaling with negligible aliasing between the baseband spectrum and its harmonics. We performed low noise power spectrum measurements on PWM modulations generated by comparing variable bandwidth, random test signals with a variable frequency triangular wave carrier. The experimental results show that power-optimized frequency scaling is both feasible and effective. The new analytical model also suggests a new PWM architecture that can be applied to digitally encoded input signals which are predistorted and compared with a cosine carrier, which is accurately synthesized by a digital oscillator. This approach has been simulated in a realistic noisy model and tested in our measurement setup. A zero crossing search on the obtained PWM modulation law proves that this approach yields an equivalent signal quality with respect to traditional PWM schemes, while entailing the use of signals whose bandwidth is remarkably smaller due to the use of a cosine instead of a triangular carrier.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’introduzione massiccia dell’elettronica di potenza nel campo degli azionamenti elettrici negli ultimi decenni ha sostanzialmente rivoluzionato la tipologia di alimentazione dei motori elettrici. Da un lato ciò ha migliorato la qualità del controllo della velocità, ma dall’altro ha aggravato le sollecitazioni che gli isolanti delle macchine devono sopportare. Si è infatti passati da tecniche di controllo tradizionali, che consistevano nell’alimentare i motori in alternata direttamente con la rete sinusoidale a 50 Hz (o a 60 Hz), ad alimentazioni indirette, cioè realizzate interponendo tra la rete e la macchina un convertitore elettronico (inverter). Tali dispositivi operano una conversione di tipo ac/dc e dc/ac che permette, come nella modulazione Pulse Width Modulation (PWM), di poter variare la frequenza di alimentazione della macchina, generando una sequenza di impulsi di larghezza variabile. Si è quindi passati dalle tradizionali alimentazioni con forme d’onda alternate sinusoidali a forme di tensione impulsive e ad elevata frequenza, cioè caratterizzate da rapidi fronti di salita e di discesa (dell’ordine di qualche kV/µs). La natura impulsiva di queste forme d’onda ha aggravato la sollecitazione elettrica a cui sono sottoposti i materiali impiegati per l’isolamento dei conduttori degli avvolgimenti delle macchine. E’ importante notare che l’utilizzo dei dispositivi elettronici, che ormai si trovano sparsi nelle reti di bassa tensione, assorbono correnti ad elevato contenuto armonico sul lato di prelievo, hanno quindi un effetto distorcente che altera l’andamento sinusoidale della rete stessa. Quindi, senza opportuni filtri, anche tutte le altre utenze connesse nelle vicinanze, dimensionate per alimentazioni sinusoidali di tipo tradizionale, possono risentire di queste distorsioni armoniche. Per tutti questi motivi è sorta la necessità di verificare l’adeguatezza dei tradizionali isolamenti ad essere in grado di sopportare le sollecitazioni che derivano dall’utilizzo di convertitori elettronici. In particolare, per i motori elettrici tale interrogativo è stato posto in seguito al verificarsi di un elevato numero di guasti inaspettati (precoci), probabilmente imputabile alla diversa sollecitazione elettrica applicata ai materiali. In questa tesi ci si è occupati della progettazione di un inverter di media tensione, che verrà impiegato per eseguire prove sugli avvolgimenti di statore di motori (formette), al fine di condurre successivamente uno studio sull’invecchiamento dei materiali che compongono gli isolamenti. Tale inverter è in grado di generare sequenze di impulsi con modulazione PWM. I parametri caratteristici delle sequenze possono essere modificati in modo da studiare i meccanismi di degradazione in funzione della tipologia delle sollecitazioni applicate. Avendo a che fare con provini di natura capacitiva, il cui isolamento può cedere durante la prova, il sistema deve essere intrinsecamente protetto nei confronti di tutte le condizioni anomale e di pericolo. In particolare deve essere in grado di offrire rapide ed efficaci protezioni per proteggere l’impianto stesso e per salvaguardare la sicurezza degli operatori, dato l’elevato livello delle tensioni in gioco. Per questo motivo è stata pensata un’architettura di sistema ad hoc, in grado di fronteggiare le situazioni anomale in modo ridondante. E’ infatti stato previsto l’inserimento di un sistema di controllo basato sul CompactRIO, sul quale è stato implementato un software in grado di monitorare le grandezze caratteristiche del sistema e le protezioni che affiancheranno quelle hardware, realizzate con dispositivi elettronici. I dispositivi elettronici di protezione e di interfacciamento sono stati studiati, implementati e simulati con PSpice, per poi essere successivamente dimensionati e realizzati su schede elettroniche, avvalendosi del software OrCAD. La tesi è strutturata come segue: - Il primo capitolo tratta, in maniera generale, i motori asincroni trifase, gli inverter e l’invecchiamento dei sistemi isolanti, con particolare interesse alle sollecitazioni meccaniche, termiche ed elettriche nel caso di sollecitazioni impulsive; - Il secondo capitolo riguarda il sistema realizzato nel suo complesso. Inizialmente verrà descritto lo schema elettrico generale, per poi analizzare più nello specifico le varie parti di cui il sistema è composto, come l’inverter di media tensione, il generatore di media tensione, la scheda di disaccoppiamento ottico, la scheda di controllo del generatore di media tensione, la scheda OCP; - Il terzo capitolo descrive le lavorazioni meccaniche eseguite sulle scatole contenti i rami di inverter, la realizzazione delle fibre ottiche e riporta le fasi di collaudo dell’intero sistema. Infine, verranno tratte le conclusioni.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays, there is a boom in the use of electrification. Electric vehicles are gaining interest worldwide due to various factors, including climate and environmental awareness. In this thesis, a step-down isolated power supply for electric tractors is investigated, specifically the phase-shifted full-bridge (PSFB) DC-DC with synchronous rectification and zero-voltage switching (ZVS). This converter was selected for its high-power capacity with high efficiency. A 3500 W PSFB converter with peak current control (PCCM) is designed and modeled in MATLAB. The input voltage range is from 550 V to 820 V and the output voltage range is limited to 9 V to 16 V with a maximum output current of 250 A. All components were commercially designed and selected, including magnetics for the high-frequency transformer and inductors, taking into account loss calculations. Zero voltage switching for the lagging leg is achieved at 13% to 100% load. The proven efficiency of the converter is around 90

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increasing interest in the decarbonization process led to a rapidly growing trend of electrification strategies in the automotive industry. In particular, OEMs are pushing towards the development and production of efficient electric vehicles. Moreover, research on electric motors and their control are exploding in popularity. The increase of computational power in embedded control hardware is allowing the development of new control algorithm, such as sensorless control strategy. Such control strategy allows the reduction of the number of sensors, which implies reduced costs and increased system reliability. The thesis objective is to realize a sensorless control for high-performance automotive motors. Several algorithms for rotor angle observers are implemented in the MATLAB and Simulink environment, with emphasis on the Kalman observer. One of the Kalman algorithms already available in the literature has been selected, implemented and benchmarked, with emphasis on its comparison with the Sliding Mode observer. Different models characterized by increasing levels of complexity are simulated. A simplified synchronous motor with ”constant parameters”, controlled by an ideal inverter is first analyzed; followed by a complete model defined by real motor maps, and controlled by a switching inverter. Finally, it was possible to test the developed algorithm on a real electric motor mounted on a test bench. A wide range of different electric motors have been simulated, which led to an exhaustive review of the sensorless control algorithm. The final results underline the capability of the Kalman observer to effectively control the motor on a real test bench.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microbial Fuel Cells (MFC) technology finds space as a promising technology as a green alternative power-generating device, by the possibility to convert organic matter directly into electricity by microbially catalysed reactions, especially for the potential of the simultaneous treatment of wastewaters. Despite the studies that were carried out over the decades, MFCs still provide insufficient power and current densities in order to be commercially attractive in the energy market. Scientific community today pursues two main strategies in order to increase the overall performance output of the MFC. The first is to support the cells with an external supercapacitor (SC), which is able to accept and deliver charge much faster than normal capacitors, thanks to the use of an electrostatic double-layer capacitance, in combination with pseudocapacitance. The second is to implement directly the SC into the MFC, by using carbon electrodes with high surface area, similar to the SC. Both strategies are eventually supported by the use of charge boosters, respect to the application of the MFC. Galvanostatic measures for the MFC and SCs are performed at different currents, alone and by integration of both devices. The SCs used have a capacitance respectively of 1F, 3F and 6F. Subsequently, a stack of MFCs is assembled and paired to a 3F SC, in order to power an ambient diffuser, able to spray at intervals with a can and a controller. In conclusion, the use of a SC in parallel to the MFCs increases the overall performance of the system. The SC remove the discharge current limit of the MFC and increases the energy and power delivered by the system, allowing it to power for a certain time the ambient diffuser successfully. The key factor highlighted by the final experiment was the insufficient charging time of the SC, resulting finally in a voltage that is inadequate to power the device. Further studies are therefore necessary to improve the performance of the MFCs.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The current design life of nuclear power plant (NPP) could potentially be extended to 80 years. During this extended plant life, all safety and operationally relevant Instrumentation & Control (I&C) systems are required to meet their designed performance requirements to ensure safe and reliable operation of the NPP, both during normal operation and subsequent to design base events. This in turn requires an adequate and documented qualification and aging management program. It is known that electrical insulation of I&C cables used in safety related circuits can degrade during their life, due to the aging effect of environmental stresses, such as temperature, radiation, vibration, etc., particularly if located in the containment area of the NPP. Thus several condition monitoring techniques are required to assess the state of the insulation. Such techniques can be used to establish a residual lifetime, based on the relationship between condition indicators and ageing stresses, hence, to support a preventive and effective maintenance program. The object of this thesis is to investigate potential electrical aging indicators (diagnostic markers) testing various I&C cable insulations subjected to an accelerated multi-stress (thermal and radiation) aging.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In recent years, energy modernization has focused on smart engineering advancements. This entails designing complicated software and hardware for variable-voltage digital substations. A digital substation consists of electrical and auxiliary devices, control and monitoring devices, computers, and control software. Intelligent measurement systems use digital instrument transformers and IEC 61850-compliant information exchange protocols in digital substations. Digital instrument transformers used for real-time high-voltage measurements should combine advanced digital, measuring, information, and communication technologies. Digital instrument transformers should be cheap, small, light, and fire- and explosion-safe. These smaller and lighter transformers allow long-distance transmission of an optical signal that gauges direct or alternating current. Cost-prohibitive optical converters are a problem. To improve the tool's accuracy, amorphous alloys are used in the magnetic circuits and compensating feedback. Large-scale voltage converters can be made cheaper by using resistive, capacitive, or hybrid voltage dividers. In known electronic voltage transformers, the voltage divider output is generally on the low-voltage side, facilitating power supply organization. Combining current and voltage transformers reduces equipment size, installation, and maintenance costs. These two gadgets cost less together than individually. To increase commercial power metering accuracy, current and voltage converters should be included into digital instrument transformers so that simultaneous analogue-to-digital samples are obtained. Multichannel ADC microcircuits with synchronous conversion start allow natural parallel sample drawing. Digital instrument transformers are created adaptable to substation operating circumstances and environmental variables, especially ambient temperature. An embedded microprocessor auto-diagnoses and auto-calibrates the proposed digital instrument transformer.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The Internet of Things (IoT) is a critical pillar in the digital transformation because it enables interaction with the physical world through remote sensing and actuation. Owing to the advancements in wireless technology, we now have the opportunity of using their features to the best of our abilities and improve over the current situation. Indeed, the Internet of Things market is expanding at an exponential rate, with devices such as alarms and detectors, smart metres, trackers, and wearables being used on a global scale for automotive and agriculture, environment monitoring, infrastructure surveillance and management, healthcare, energy and utilities, logistics, good tracking, and so on. The Third Generation Partnership Project (3GPP) acknowledged the importance of IoT by introducing new features to support it. In particular, in Rel.13, the 3GPP introduced the so-called IoT to support Low Power Wide Area Networks (LPWAN).As these devices will be distributed in areas where terrestrial networks are not feasible or commercially viable, satellite networks will play a complementary role due to their ability to provide global connectivity via their large footprint size and short service deployment time. In this context, the goal of this thesis is to investigate the viability of integrating IoT technology with satellite communication (SatCom) systems, with a focus on the Random Access(RA) Procedure. Indeed, the RA is the most critical procedure because it allows the UE to achieve uplink synchronisation, obtain the permanent ID, and obtain uplink transmission resources. The goal of this thesis is to evaluate preamble detection in the SatCom environment.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In the field of industrial automation, there is an increasing need to use optimal control systems that have low tracking errors and low power and energy consumption. The motors we are dealing with are mainly Permanent Magnet Synchronous Motors (PMSMs), controlled by 3 different types of controllers: a position controller, a speed controller, and a current controller. In this thesis, therefore, we are going to act on the gains of the first two controllers by going to find, through the TwinCAT 3 software, what might be the best set of parameters. To do this, starting with the default parameters recommended by TwinCAT, two main methods were used and then compared: the method of Ziegler and Nichols, which is a tabular method, and advanced tuning, an auto-tuning software method of TwinCAT. Therefore, in order to analyse which set of parameters was the best,several experiments were performed for each case, using the Motion Control Function Blocks. Moreover, some machines, such as large robotic arms, have vibration problems. To analyse them in detail, it was necessary to use the Bode Plot tool, which, through Bode plots, highlights in which frequencies there are resonance and anti-resonance peaks. This tool also makes it easier to figure out which and where to apply filters to improve control.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Laser Shock Peening (LSP) is a surface enhancement treatment which induces a significant layer of beneficial compressive residual stresses of up to several mm underneath the surface of metal components in order to improve the detrimental effects of the crack growth behavior rate in it. The aim of this thesis is to predict the crack growth behavior in metallic specimens with one or more stripes which define the compressive residual stress area induced by the Laser Shock Peening treatment. The process was applied as crack retardation stripes perpendicular to the crack propagation direction with the object of slowing down the crack when approaching the peened stripes. The finite element method has been applied to simulate the redistribution of stresses in a cracked model when it is subjected to a tension load and to a compressive residual stress field, and to evaluate the Stress Intensity Factor (SIF) in this condition. Finally, the Afgrow software is used to predict the crack growth behavior of the component following the Laser Shock Peening treatment and to detect the improvement in the fatigue life comparing it to the baseline specimen. An educational internship at the “Research & Technologies Germany – Hamburg” department of AIRBUS helped to achieve knowledge and experience to write this thesis. The main tasks of the thesis are the following: •To up to date Literature Survey related to “Laser Shock Peening in Metallic Structures” •To validate the FE model developed against experimental measurements at coupon level •To develop design of crack growth slowdown in Centered Cracked Tension specimens based on residual stress engineering approach using laser peened strip transversal to the crack path •To evaluate the Stress Intensity Factor values for Centered Cracked Tension specimens after the Laser Shock Peening treatment via Finite Element Analysis •To predict the crack growth behavior in Centered Cracked Tension specimens using as input the SIF values evaluated with the FE simulations •To validate the results by means of experimental tests

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis work aims to find a procedure for isolating specific features of the current signal from a plasma focus for medical applications. The structure of the current signal inside a plasma focus is exclusive of this class of machines and a specific analysis procedure has to be developed. The hope is to find one or more features that shows a correlation with the dose erogated. The study of the correlation between the current discharge signal and the dose delivered by a plasma focus could be of some importance not only for the practical application of dose prediction but also for expanding the knowledge anbout the plasma focus physics. Vatious classes of time-frequency analysis tecniques are implemented in order to solve the problem.