2 resultados para POLYIMIDE MEMBRANES

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work, the deviations in the solubility of CO2, CH4, and N2 at 30 °c in the mixed gases (CO2/CH4) and (CO2/N2) from the pure gas behavior were studied using the dual-mode model over a wide range of equilibrium composition and pressure values in two glassy polymers. The first of which was PI-DAR which is the polyimide formed by the reaction between 4, 6-diaminoresorcinol dihydrochloride (DAR-Cl) and 2, 2’-bis-(3, 4-dicarboxyphenyl) hexafluoropropane dianhydride (6FDA). The other glassy polymer was TR-DAR which is the corresponding thermally rearranged polymer of PI-DAR. Also, mixed gas sorption experiments for the gas mixture (CO2/CH4) in TR-DAR at 30°c took place in order to assess the degree of accuracy of the dual-mode model in predicting the true mixed gas behavior. The experiments were conducted on a pressure decay apparatus coupled with a gas chromatography column. On the other hand, the solubility of CO2 and CH4 in two rubbery polymers at 30⁰c in the mixed gas (CO2/CH4) was modelled using the Lacombe and Sanchez equation of state at various values of equilibrium composition and pressure. These two rubbery polymers were cross-linked poly (ethylene oxide) (XLPEO) and poly (dimethylsiloxane) (PDMS). Moreover, data about the sorption of CO2 and CH4 in liquid methyl dietahnolamine MDEA that was collected from literature65-67 was used to determine the deviations in the sorption behavior in the mixed gas from that in the pure gases. It was observed that the competition effects between the penetrants were prevailing in the glassy polymers while swelling effects were predominant in the rubbery polymers above a certain value of the fugacity of CO2. Also, it was found that the dual-mode model showed a good prediction of the sorption of CH4 in the mixed gas for small pressure values but in general, it failed to predict the actual sorption of the penetrants in the mixed gas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Protein purification plays a crucial role in biotechnology and biomanufacturing, where downstream unit operations account for 40%-80% of the overall costs. To overcome this issue, companies strive to simplify the separation process by reducing the number of steps and replacing expensive separation devices. In this context, commercially available polybutylene terephthalate (PBT) melt-blown nonwoven membranes have been developed as a novel disposable membrane chromatography support. The PBT nonwoven membrane is able to capture products and reduce contaminants by ion exchange chromatography. The PBT nonwoven membrane was modified by grafting a poly(glycidyl methacrylate) (GMA) layer by either photo-induced graft polymerization or heat induced graft polymerization. The epoxy groups of GMA monomer were subsequently converted into cation and anion exchangers by reaction with either sulfonic acid groups or diethylamine (DEA), respectively. Several parameters of the procedure were studied, especially the effect of (i) % weight gain and (ii) ligand density on the static protein binding capacity. Bovine Serum Albumin (BSA) and human Immunoglobulin G (hIgG) were utilized as model proteins in the anion and cation exchange studies. The performance of ion exchange PBT nonwovens by HIG was evaluated under flow conditions. The anion- and cation- exchange HIG PBT nonwovens were evaluated for their ability to selectively adsorb and elute BSA or hIgG from a mixture of proteins. Cation exchange nonwovens were not able to reach a good protein separation, whereas anion exchange HIG nonwovens were able to absorb and elute BSA with very high value of purity and yield, in only one step of purification.