4 resultados para Optical multi-channel analyzer

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The GRAIN detector is part of the SAND Near Detector of the DUNE neutrino experiment. A new imaging technique involving the collection of the scintillation light will be used in order to reconstruct images of particle tracks in the GRAIN detector. Silicon photomultiplier (SiPM) matrices will be used as photosensors for collecting the scintillation light emitted at 127 nm by liquid argon. The readout of SiPM matrices inside the liquid argon requires the use of a multi-channel mixed-signal ASIC, while the back-end electronics will be implemented in FPGAs outside the cryogenic environment. The ALCOR (A Low-power Circuit for Optical sensor Readout) ASIC, developed by Torino division of INFN, is under study, since it is optimized to readout SiPMs at cryogenic temperatures. I took part in the realization of a demonstrator of the imaging system, which consists of a SiPM matrix connected to a custom circuit board, on which an ALCOR ASIC is mounted. The board communicates with an FPGA. The first step of the present project that I have accomplished was the development of an emulator for the ALCOR ASIC. This emulator allowed me to verify the correct functioning of the initial firmware before the real ASIC itself was available. I programmed the emulator using VHDL and I also developed test benches in order to test its correct working. Furthermore, I developed portions of the DAQ software, which I used for the acquisition of data and the slow control of the ASICs. In addition, I made some parts of the DAQ firmware for the FPGAs. Finally, I tested the complete SiPMs readout system at both room and cryogenic temperature in order to ensure its full functionality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The constantly increasing demand of clean water has become challenging to deal with over the past years, water being an ever more precious resource. In recent times, the existing wastewater treatments had to be integrated with new steps, due to the detection of so-called organic micropollutants (OMPs). These compounds have been shown to adversely affect the environment and possibly human health, even when found in very low concentrations. In order to remove OMPs from wastewater, one possible technique is a hybrid process combining filtration and adsorption. In this work, polyethersulfone multi-channel mixed-matrix membranes with embedded powdered activated carbon (PAC) were tested to investigate the membrane’s adsorption and desorption performance. Micropollutants retention was analyzed using the pharmaceutical compounds diclofenac (DCF), paracetamol (PARA) and carbamazepine (CBZ) in filtration mode, combining the PAC adsorption process with the membrane’s ultrafiltration. Desorption performance was studied through solvent regeneration, using seven different solvents: pure water, pure ethanol, mixture of ethanol and water in different concentration, sodium hydroxide and a mixture of ethanol and sodium hydroxide. Regeneration experiments were carried out in forward-flushing. At first regeneration efficiency was investigated using a single-solute solution (diclofenac in water). The mixture Ethanol/Water (50:50) was found to be the most efficient with long-term retention of 59% after one desorption cycle. It was, therefore, later tested on a membrane previously loaded with a multi-solute solution. Three desorption cycles were performed after which, retention (after 30 min) reached values of 87% for PARA and 72% for CBZ and 55% for DCF, which indicates decent regenerability. A morphological analysis on the membranes confirmed that, in any case, the regeneration cycles did not affect either the membranes’ structure, or the content and distribution of PAC in the matrix.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This dissertation analyzes the exploitation of the orbital angular momentum (OAM) of the electromagnetic waves with large intelligent surfaces in the near-field region and line-of-sight conditions, in light of the holographic MIMO communication concept. Firstly, a characterization of the OAM-based communication problem is presented, and the relationship between OAM-carrying waves and communication modes is discussed. Then, practicable strategies for OAM detection using large intelligent surfaces and optimization methods based on beam focusing are proposed. Numerical results characterize the effectiveness of OAM with respect to other strategies, also including the proposed detection and optimization methods. It is shown that OAM waves constitute a particular choice of communication modes, i.e., an alternative basis set, which is sub-optimum with respect to optimal basis functions that can be derived by solving eigenfunction problems. Moreover, even the joint utilization of OAM waves with focusing strategies led to the conclusion that no channel capacity achievements can be obtained with these transmission techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis explores the X-ray nuclear and extended properties of the radio galaxy 3C 277.3, where a recent optical observation performed with the multi-unit spectroscopic explorer (MUSE) has revealed star-forming regions triggered by the propagation of non-thermal plasma in the intergalactic medium. This work aims to study the nuclear engine and its environment and, possibly, discover signatures of non-thermal plasma-gas interaction at high energies. 3C 277.3 was observed with the Chandra satellite five times from 2010 to 2014 for a total of about 200 ks. Data in the Chandra public archive were retrieved and analyzed. When necessary, the different pointings were combined to improve the signal-to-noise ratio. A detailed analysis of the Chandra image (obtained by combining all the observations) has revealed several emission regions. In addition to a bright nucleus, two jet knots and the northern hot spot were clearly detected by overlapping the X-ray data to a VLA map of the source at 1.4 GHz. An X-ray spectral analysis was performed for all these structures. Finally, the X-ray image was over-imposed on the MUSE data.