3 resultados para Negative factor counting method

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Arrhythmia is one kind of cardiovascular diseases that give rise to the number of deaths and potentially yields immedicable danger. Arrhythmia is a life threatening condition originating from disorganized propagation of electrical signals in heart resulting in desynchronization among different chambers of the heart. Fundamentally, the synchronization process means that the phase relationship of electrical activities between the chambers remains coherent, maintaining a constant phase difference over time. If desynchronization occurs due to arrhythmia, the coherent phase relationship breaks down resulting in chaotic rhythm affecting the regular pumping mechanism of heart. This phenomenon was explored by using the phase space reconstruction technique which is a standard analysis technique of time series data generated from nonlinear dynamical system. In this project a novel index is presented for predicting the onset of ventricular arrhythmias. Analysis of continuously captured long-term ECG data recordings was conducted up to the onset of arrhythmia by the phase space reconstruction method, obtaining 2-dimensional images, analysed by the box counting method. The method was tested using the ECG data set of three different kinds including normal (NR), Ventricular Tachycardia (VT), Ventricular Fibrillation (VF), extracted from the Physionet ECG database. Statistical measures like mean (μ), standard deviation (σ) and coefficient of variation (σ/μ) for the box-counting in phase space diagrams are derived for a sliding window of 10 beats of ECG signal. From the results of these statistical analyses, a threshold was derived as an upper bound of Coefficient of Variation (CV) for box-counting of ECG phase portraits which is capable of reliably predicting the impeding arrhythmia long before its actual occurrence. As future work of research, it was planned to validate this prediction tool over a wider population of patients affected by different kind of arrhythmia, like atrial fibrillation, bundle and brunch block, and set different thresholds for them, in order to confirm its clinical applicability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Damage tolerance analysis is a quite new methodology based on prescribed inspections. The load spectra used to derive results of these analysis strongly influence the final defined inspections programs that for this reason must be as much as possible representative of load acting on the considered structural component and at the same time, obtained reducing both cost and time. The principal purpose of our work is in improving the actual condition developing a complete numerical Damage Tolerance analysis, able to prescribe inspection programs on typical aircraft critical components, respecting DT regulations, starting from much more specific load spectrum then those actually used today. In particular, these more specific load spectrum to design against fatigue have been obtained through an appositively derived flight simulator developed in a Matlab/Simulink environment. This dynamic model has been designed so that it can be used to simulate typical missions performing manually (joystick inputs) or completely automatic (reference trajectory need to be provided) flights. Once these flights have been simulated, model’s outputs are used to generate load spectrum that are then processed to get information (peaks, valleys) to perform statistical and/or comparison consideration with other load spectrum. However, also much more useful information (loads amplitude) have been extracted from these generated load spectrum to perform the previously mentioned predictions (Rainflow counting method is applied for this purpose). The entire developed methodology works in a complete automatic way, so that, once some specified input parameters have been introduced and different typical flights have been simulated both, manually or automatically, it is able to relate the effects of these simulated flights with the reduction of residual strength of the considered component.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new method for the evaluation of the efficiency of parabolic trough collectors, called Rapid Test Method, is investigated at the Solar Institut Jülich. The basic concept is to carry out measurements under stagnation conditions. This allows a fast and inexpensive process due to the fact that no working fluid is required. With this approach, the temperature reached by the inner wall of the receiver is assumed to be the stagnation temperature and hence the average temperature inside the collector. This leads to a systematic error which can be rectified through the introduction of a correction factor. A model of the collector is simulated with COMSOL Multipyisics to study the size of the correction factor depending on collector geometry and working conditions. The resulting values are compared with experimental data obtained at a test rig at the Solar Institut Jülich. These results do not match with the simulated ones. Consequentially, it was not pos-sible to verify the model. The reliability of both the model with COMSOL Multiphysics and of the measurements are analysed. The influence of the correction factor on the rapid test method is also studied, as well as the possibility of neglecting it by measuring the receiver’s inner wall temperature where it receives the least amount of solar rays. The last two chapters analyse the specific heat capacity as a function of pressure and tem-perature and present some considerations about the uncertainties on the efficiency curve obtained with the Rapid Test Method.