5 resultados para IMRT QUALITY-ASSURANCE
em AMS Tesi di Laurea - Alm@DL - Università di Bologna
Resumo:
Compaction is one of the most important processes in roadway construction. It is needed to achieve high quality and uniformity of pavement materials, which in turn better ensure long lasting performance.
Resumo:
Magnetic Resonance Spectroscopy (MRS) is an advanced clinical and research application which guarantees a specific biochemical and metabolic characterization of tissues by the detection and quantification of key metabolites for diagnosis and disease staging. The "Associazione Italiana di Fisica Medica (AIFM)" has promoted the activity of the "Interconfronto di spettroscopia in RM" working group. The purpose of the study is to compare and analyze results obtained by perfoming MRS on scanners of different manufacturing in order to compile a robust protocol for spectroscopic examinations in clinical routines. This thesis takes part into this project by using the GE Signa HDxt 1.5 T at the Pavillion no. 11 of the S.Orsola-Malpighi hospital in Bologna. The spectral analyses have been performed with the jMRUI package, which includes a wide range of preprocessing and quantification algorithms for signal analysis in the time domain. After the quality assurance on the scanner with standard and innovative methods, both spectra with and without suppression of the water peak have been acquired on the GE test phantom. The comparison of the ratios of the metabolite amplitudes over Creatine computed by the workstation software, which works on the frequencies, and jMRUI shows good agreement, suggesting that quantifications in both domains may lead to consistent results. The characterization of an in-house phantom provided by the working group has achieved its goal of assessing the solution content and the metabolite concentrations with good accuracy. The goodness of the experimental procedure and data analysis has been demonstrated by the correct estimation of the T2 of water, the observed biexponential relaxation curve of Creatine and the correct TE value at which the modulation by J coupling causes the Lactate doublet to be inverted in the spectrum. The work of this thesis has demonstrated that it is possible to perform measurements and establish protocols for data analysis, based on the physical principles of NMR, which are able to provide robust values for the spectral parameters of clinical use.
Resumo:
Vengono analizzate le strategie di rilascio delle principali Distribuzioni Linux e i metodi per la compilazione automatizzata del software. Si propone quindi una nuova metodologia sia per il rilascio di media installabili e sia per la pacchettizzazione. Sfruttando le tecnologie del campo DevOps, si introduce quindi un alto grado di scalabilità anche in ambienti Cloud, grazie anche alla riproducibilità di ogni componente dell'infrastruttura proposta. Vedremo quindi come questo approccio aumenta l'automatizzazione nei cicli produttivi per la realizzazione della Distribuzione Sabayon Linux e per la definizione di un'infrastruttura automatizzata attualmente in production.
Resumo:
Correctness of information gathered in production environments is an essential part of quality assurance processes in many industries, this task is often performed by human resources who visually take annotations in various steps of the production flow. Depending on the performed task the correlation between where exactly the information is gathered and what it represents is more than often lost in the process. The lack of labeled data places a great boundary on the application of deep neural networks aimed at object detection tasks, moreover supervised training of deep models requires a great amount of data to be available. Reaching an adequate large collection of labeled images through classic techniques of data annotations is an exhausting and costly task to perform, not always suitable for every scenario. A possible solution is to generate synthetic data that replicates the real one and use it to fine-tune a deep neural network trained on one or more source domains to a different target domain. The purpose of this thesis is to show a real case scenario where the provided data were both in great scarcity and missing the required annotations. Sequentially a possible approach is presented where synthetic data has been generated to address those issues while standing as a training base of deep neural networks for object detection, capable of working on images taken in production-like environments. Lastly, it compares performance on different types of synthetic data and convolutional neural networks used as backbones for the model.
Resumo:
Digital Breast Tomosynthesis (DBT) is an advanced mammography technique based on the reconstruction of a pseudo-volumetric image. To date, image quality represents the most deficient section of DBT quality control protocols. In fact, related tests are not yet characterized by either action levels or typical values. This thesis work focuses on the evaluation of one aspect of image quality: the z-resolution. The latter is studied in terms of Artifact Spread Function (ASF), a function that describes the signal spread of a detail along the reconstructed focal planes. To quantify the ASF numerically, its Full Width at Half Maximum (FWHM) is calculated and used as a representative index of z-resolution. Experimental measurements were acquired in 24 DBT systems, of 7 different models, currently in use in 20 hospital facilities in Italy. The analysis, performed on the clinical reconstructed images, of 5 different commercial phantoms, lead to the identification of characteristic FWHM values for each type of DBT system. The ASF clearly showed a dependence on the size of the detail, providing higher FWHM values for larger objects. The z-resolution was found to be positively influenced by the acquisition angle: Fujifilm sistematically showed wider ASF profiles in ST mode (15°) than in HR mode (40°). However, no clear relationship was found between angular range and ASF, among different DBT systems, due to the influence of the peculiarities of each reconstruction algorithm. The experimental approach shown in this thesis work can be proposed as a z-resolution quality control test procedure. Contextually, the values found could be used as a starting point for identifying typical values to be included in the test, in a DBT protocol. Clearly, a statistically significant number of images is needed to do this. The equipment involved in this work is located in hospitals and is not available for research purposes, so only a limited amount of data was acquired and processed.