2 resultados para Heart failure - Thesis
em AMS Tesi di Laurea - Alm@DL - Università di Bologna
Resumo:
The present study investigates the feasibility of a new application able to check the heart failure status in a patient through the estimation of the venous distension. In this way it would be possible to follow up patients, avoiding invasive or expensive exams such as cardiac catheterization and echocardiography. Moreover, the devices would also be able to diagnose the decline of the disease, in order to allow a new adaptation to therapy, and vice versa to check the improvement in the patient’s conditions after the CRT device implant. This thesis is essentially divided into three parts: an analytical model was used to obtain an estimation of the error committed for the calculation of the CSA and to understand how the accuracy and sensitivity depend on the different configurations of the electrodes and the catheter position inside the vein; secondly, an in-vitro experiment was carried out in order to verify the practical feasibility for these kinds of measurements, in a very simplified model; in the end, several animal experiments were done to test the in-vivo practicability of the proposed method. The obtained results showed the feasibility of this approach. In fact, the error committed in the estimation of CSA, during the animal experiments, can be considered acceptable (CSAerror_max ≈ -14%). Moreover, it has been demonstrated that the conductance catheter allows assessing, not only the vein CSA, but also the breathing of the animal.
Resumo:
In cardiovascular disease the definition and the detection of the ECG parameters related to repolarization dynamics in post MI patients is still a crucial unmet need. In addition, the use of a 3D sensor in the implantable medical devices would be a crucial mean in the assessment or prediction of Heart Failure status, but the inclusion of such feature is limited by hardware and firmware constraints. The aim of this thesis is the definition of a reliable surrogate of the 500 Hz ECG signal to reach the aforementioned objective. To evaluate the worsening of reliability due to sampling frequency reduction on delineation performance, the signals have been consecutively down sampled by a factor 2, 4, 8 thus obtaining the ECG signals sampled at 250, 125 and 62.5 Hz, respectively. The final goal is the feasibility assessment of the detection of the fiducial points in order to translate those parameters into meaningful clinical parameter for Heart Failure prediction, such as T waves intervals heterogeneity and variability of areas under T waves. An experimental setting for data collection on healthy volunteers has been set up at the Bakken Research Center in Maastricht. A 16 – channel ambulatory system, provided by TMSI, has recorded the standard 12 – Leads ECG, two 3D accelerometers and a respiration sensor. The collection platform has been set up by the TMSI property software Polybench, the data analysis of such signals has been performed with Matlab. The main results of this study show that the 125 Hz sampling rate has demonstrated to be a good candidate for a reliable detection of fiducial points. T wave intervals proved to be consistently stable, even at 62.5 Hz. Further studies would be needed to provide a better comparison between sampling at 250 Hz and 125 Hz for areas under the T waves.