2 resultados para HUMAN BODY
em AMS Tesi di Laurea - Alm@DL - Università di Bologna
Resumo:
In the last years the number of shoulder arthroplasties has been increasing. Simultaneously the study of their shape, size and strength and the reasons that bring to a possible early explantation have not yet been examined in detail. The research carried out directly on explants is practically nonexistent, this means a poor understanding of the mechanisms leading the patient and so the surgeon, to their removal. The analysis of the mechanisms which are the cause of instability, dislocation, broken, fracture, etc, may lead to a change in the structure or design of the shoulder prostheses and lengthen the life of the implant in situ. The idea was to analyze 22 explants through three methods in order to find roughness, corrosion and surface wear. In the first method, the humeral heads and/or the glenospheres were examined with the interferometer, a machine that through electromagnetic waves gives information about the roughness of the surfaces under examination. The output of the device was a total profile containing both roughness and information on the waves (representing the spatial waves most characteristic on the surface). The most important value is called "roughness average" and brings the average value of the peaks found in the local defects of the surfaces. It was found that 42% of the prostheses had considerable peak values in the area where the damage was caused by the implant and not only by external events, such as possibly the surgeon's hand. One of the problems of interest in the use of metallic biomaterials is their resistance to corrosion. The clinical significance of the degradation of metal implants has been the purpose of the second method; the interaction between human body and metal components is critical to understand how and why they arrive to corrosion. The percentage of damage in the joints of the prosthetic components has been calculated via high resolution photos and the software ImageJ. The 40% and 50% of the area appeared to have scratches or multiple lines due to mechanical artifacts. The third method of analysis has been made through the use of electron microscopy to quantify the wear surface in polyethylene components. Different joint movements correspond to different mechanisms of damage, which were imprinted in the parts of polyethylene examined. The most affected area was located mainly in the side edges. The results could help the manufacturers to modify the design of the prostheses and thus reduce the number of explants. It could also help surgeons in choosing the model of the prosthesis to be implanted in the patient.
Resumo:
The spinal column performs important functions in the body, including the support of the entire weight of the human body, the ability to orientate the head in space, bending, flexing and rotating the body. Diseases affecting the spine are manifold: the most frequent is scoliosis, which often affects the female population. It is often treated surgically with a very high percentage of failures. The aim of the thesis is to study the role of instrumentation in mechanical failures encountered 12 months after surgery in the treatment of scoliosis. For the purposes of the study, we analyzed specific biomechanical parameters. The pelvic angles determine the position of the pelvis, while the imbalance parameters the structure of the body. We infer other parameters by analyzing the characteristics of the implanted instrumentation. Initially, the anatomy is described of the spine and vertebrae, the equipment used and the possible failures that may occur after surgery. Subsequently, the materials and methods used for the analysis of the above-mentioned parameters for the 61 patients are reported. All data are obtained by the observation of pre and post-operative x-rays with a special program, by reading reports from operators and by medical records. In the fourth chapter, we report the results: the overall failure rate is 60.9%; the types of failures that occurred are rupture of bars and rupture of bars simultaneously to PJK. The most influential parameters on results of the progress of the surgery are the type of material used and the BMI. It is estimated a high percentage of failures in patients treated with implants of cobalt chromium alloys (90.0%). According to the results obtained, it is possible to understand the aspects that in the future should be studied, in order to find a solution to the most frequent surgical failures.