9 resultados para EPITHERMAL NEUTRON-SPECTRUM
em AMS Tesi di Laurea - Alm@DL - Università di Bologna
Resumo:
In this thesis, numerical methods aiming at determining the eigenfunctions, their adjoint and the corresponding eigenvalues of the two-group neutron diffusion equations representing any heterogeneous system are investigated. First, the classical power iteration method is modified so that the calculation of modes higher than the fundamental mode is possible. Thereafter, the Explicitly-Restarted Arnoldi method, belonging to the class of Krylov subspace methods, is touched upon. Although the modified power iteration method is a computationally-expensive algorithm, its main advantage is its robustness, i.e. the method always converges to the desired eigenfunctions without any need from the user to set up any parameter in the algorithm. On the other hand, the Arnoldi method, which requires some parameters to be defined by the user, is a very efficient method for calculating eigenfunctions of large sparse system of equations with a minimum computational effort. These methods are thereafter used for off-line analysis of the stability of Boiling Water Reactors. Since several oscillation modes are usually excited (global and regional oscillations) when unstable conditions are encountered, the characterization of the stability of the reactor using for instance the Decay Ratio as a stability indicator might be difficult if the contribution from each of the modes are not separated from each other. Such a modal decomposition is applied to a stability test performed at the Swedish Ringhals-1 unit in September 2002, after the use of the Arnoldi method for pre-calculating the different eigenmodes of the neutron flux throughout the reactor. The modal decomposition clearly demonstrates the excitation of both the global and regional oscillations. Furthermore, such oscillations are found to be intermittent with a time-varying phase shift between the first and second azimuthal modes.
Resumo:
Il presente lavoro di tesi, sviluppato nell’arco di sei mesi presso l’Institut Supérieur Industriel de Bruxelles (ISIB) in collaborazione con Ion Beam Application Group (IBA, Louvain la Neuve), ha come principale soggetto lo studio della risposta del rem meter WENDI-2 commercializzato da Thermo Scientific. Lo studio si è basato principalmente sull’uso del codice Monte Carlo MCNPX 2.5.0, simulando la risposta del detector sia in caso di campi di radiazione neutronica monoenergetici sia in corrispondenza di spettri neutronici continui. La prima fase è stata dedicata alla modellizzazione MCNPX del rem counter, consentendo così la valutazione della sua funzione risposta. Questa è stata ricostruita interpolando 93 punti, ciascuno calcolato in corrispondenza di un singolo valore di energia di una sorgente puntiforme, compreso tra 1 meV e 5 GeV. In tal caso è stata rilevata un’ottima corrispondenza tra i risultati ottenuti e quelli riportati nella letteratura scientifica esistente. In una seconda fase, al fine di ottenere informazioni sulla risposta di WENDI II in corrispondenza di campi complessi di radiazione, simulazioni MCNPX sono state realizzate riproducendo un ambiente di lavoro esistente presso la sede IBA di Louvain la Neuve: la risposta del detector è stata valutata in corrispondenza di 9 diverse posizioni all’interno di un bunker contenente un ciclotrone PET (18 MeV H-), implicando la rilevazione di campi di radiazione neutronica continui ed estesi dalle energie termiche fino a 18 MeV. I risultati ottenuti sono stati infine comparati con i valori di dose ambiente equivalente calcolata nelle stesse condizioni di irraggiamento.
Resumo:
Spectrum sensing su piattaforma software defined radio: Implementazione e test su stick dvb-t
Resumo:
In questo elaborato vengono discusse le catene di spin-1, modelli quantistici definiti su un reticolo unidimensionale con interazione tra siti primi vicini. Fra la ricca varietà di tipologie esistenti è stato scelto di porre attenzione primariamente sul modello antiferromagnetico con interazione puramente biquadratica. Vengono presentati diversi metodi di classificazione degli autostati di tale modello, a partire dalle simmetrie che ne caratterizzano l’Hamiltoniana. La corrispondenza con altri modelli noti, quali il modello XXZ di spin 1/2, la catena di Heisenberg SU (3) ed i modelli di Potts, è utile ad individuare strutture simmetriche nascoste nel formalismo di spin-1, le quali consentono di ricavare informazioni sullo spettro energetico. Infine, vengono presentati risultati numerici accompagnati da alcune considerazioni sulle modifiche dello spettro quando si aggiunge un termine bilineare alla Hamiltoniana biquadratica.
Resumo:
Damage tolerance analysis is a quite new methodology based on prescribed inspections. The load spectra used to derive results of these analysis strongly influence the final defined inspections programs that for this reason must be as much as possible representative of load acting on the considered structural component and at the same time, obtained reducing both cost and time. The principal purpose of our work is in improving the actual condition developing a complete numerical Damage Tolerance analysis, able to prescribe inspection programs on typical aircraft critical components, respecting DT regulations, starting from much more specific load spectrum then those actually used today. In particular, these more specific load spectrum to design against fatigue have been obtained through an appositively derived flight simulator developed in a Matlab/Simulink environment. This dynamic model has been designed so that it can be used to simulate typical missions performing manually (joystick inputs) or completely automatic (reference trajectory need to be provided) flights. Once these flights have been simulated, model’s outputs are used to generate load spectrum that are then processed to get information (peaks, valleys) to perform statistical and/or comparison consideration with other load spectrum. However, also much more useful information (loads amplitude) have been extracted from these generated load spectrum to perform the previously mentioned predictions (Rainflow counting method is applied for this purpose). The entire developed methodology works in a complete automatic way, so that, once some specified input parameters have been introduced and different typical flights have been simulated both, manually or automatically, it is able to relate the effects of these simulated flights with the reduction of residual strength of the considered component.
Resumo:
Durante il Long Shutdown 1 di LHC sono stati cambiati i fotomoltiplicatori del rivelatore di luminosità LUCID di ATLAS. I due modelli candidati per la sostituzione sono stati sottoposti a test di resistenza alla radiazione di gamma e neutroni. In questa tesi si riportano i risultati delle misure di dark current, risposta spettrale, guadagno relativo e assoluto, prima e dopo l’irraggiamento con neutroni. L’unica differenza di rilievo riguarda un aumento della dark current, gli altri parametri non presentano variazioni entro la precisione delle misure. Non ci sono differenze sostanziali tra i due modelli per quanto riguarda la resistenza alle radiazioni.
Resumo:
L'obiettivo di questo lavoro è quello di analizzare la stabilità di uno spettro raggi X emesso da un tubo usurato per analisi cardiovascolari, in modo da verificare il suo comportamento. Successivamente questo tipo di analisi sarà effettuata su tubi CT. Per raggiungere questo scopo è stato assemblato un particolare set-up con un rivelatore al germanio criogenico in modo da avere la miglior risoluzione energetica possibile ed alcuni particolari collimatori così da ridurre il flusso fotonico per evitare effetti di pile-up. Il set-up è stato costruito in modo da avere il miglior allineamento possibile nel modo più veloce possibile, e con l'obiettivo di rendere l'intero sistema portabile. Il tubo usato è un SRM Philips tube per analisi cardiovascolari; questa scelta è stata fatta in modo da ridurre al minimo i fattori esterni (ottica elettromagnetica, emettitori) e concentrare l'attenzione solo sugli effetti, causati dalle varie esposizioni, sull'anodo (roughness e bending) e sul comportamento di essi durante il surriscaldamento e successivo raffreddamento del tubo. I risultati mostrano come durante un'esposizione alcuni fattori di usura del tubo possono influire in maniera sostanziale sullo spettro ottenuto e quindi alterare il risultato. Successivamente, nell'elaborato, mediante il software Philips di ricostruzione e simulazione dello spettro si è cercato di riprodurre, variando alcuni parametri, la differenza riscontrata sperimentalmente in modo da poter simulare l'instabilità e correggere i fattori che la causano. I risultati sono interessanti non solo per questo esperimento ma anche in ottica futura, per lo sviluppo di applicazioni come la spectral CT. Il passo successivo sarà quello di spostare l'attenzione su un CT tube e verificare se l'instabilità riscontrata in questo lavoro è persiste anche in una analisi più complessa come quella CT.