7 resultados para COMPUTED-TOMOGRAPHY

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In questo studio ci siamo proposti di investigare i sistemi di modulazione automatica della dose sui sistemi TC Multislice (Automatic Exposure Control – AEC) da tre diversi produttori, aventi differenti indicatori di qualità delle immagini. Il presente lavoro è stato svolto presso il Servizio di Fisica Sanitaria dell’Azienda Ospedaliera Universitaria - Policlinico Sant’Orsola-Malpighi di Bologna e consiste in un’analisi quantitativa della dose impiegata durante esami di Tomografia Computerizzata Multi-Slice (TCMS) e delle rispettive immagini radiologiche. Le immagini sono state acquisite con : GE LightSpeed VCT 64 e GE LightSpeed 16 (AEC AutomA 3D longitudinale e angolare), Siemens Sensation 16 (AEC CARE Dose 4D combinato), Philips Brilliance 16 e iCT 64 (separati in AEC ZDOM longitudinale e AEC DDOM angolare). Le acquisizioni TCMS sono state effettuate a differenti kV e mA di riferimento, al fine di investigarne gli effetti sulla modulazione, impiegando algoritmi di ricostruzione standard presenti su ogni macchina. Due fantocci antropomorfi simulanti la zona del torace e dell’addome sono stati utilizzati per simulare un paziente standard posizionato come in un esame clinico di routine ; a questo proposito, sono stati impiegati protocolli elicoidali standard con e senza modulazione. Sono inoltre stati testati differenti valori di indice di qualità delle immagini. Il profilo dei mA lungo la lunghezza è stato ottenuto utilizzando ImageJ, un programma open source comunemente utilizzato per l’elaborazione di immagini; i mAs sono stati normalizzati ad un fattore che tiene conto delle differenti geometrie e delle filtrazioni dei diversi scanner tomografici analizzati nell’esperienza. Il rumore è stato valutato tramite la scelta di determinate ROI (Region Of Interest) localizzate in aree il più possibili uniformi disponibili lungo i fantocci. Abbiamo registrato che una variazione del Noise Index o dei mAs di riferimento a seconda della tipologia di macchina analizzata risulta in uno shift dei profili di dose; lo stesso si è verificato quando sono stati cambiato kV o mA nella scout di acquisizione. Sistemi AEC longitudinali e combinati hanno mostrato profili di mAs normalizzati simili tra loro, con valori elevati evidenziati nella zona delle spalle e zona pelvi; sono state osservate differenze del 30-40% tra i differenti scanner tomografici. Solo in un caso di macchina analizzata si è verificato un comportamento opposto rispetto alle altre due tipologie di macchina in esame. A dispetto della differente natura dei sistemi AEC, i risultati ottenuti dai protocolli combinati e longitudinali sono simili tra loro. Il rumore presente nelle immagini è aumentato ad un livello accettabile e la sua uniformità lungo la direzione di scan è migliorata.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il presente lavoro di tesi è stato svolto presso il servizio di Fisica Sanitaria del Policlinico Sant'Orsola-Malpighi di Bologna. Lo studio si è concentrato sul confronto tra le tecniche di ricostruzione standard (Filtered Back Projection, FBP) e quelle iterative in Tomografia Computerizzata. Il lavoro è stato diviso in due parti: nella prima è stata analizzata la qualità delle immagini acquisite con una CT multislice (iCT 128, sistema Philips) utilizzando sia l'algoritmo FBP sia quello iterativo (nel nostro caso iDose4). Per valutare la qualità delle immagini sono stati analizzati i seguenti parametri: il Noise Power Spectrum (NPS), la Modulation Transfer Function (MTF) e il rapporto contrasto-rumore (CNR). Le prime due grandezze sono state studiate effettuando misure su un fantoccio fornito dalla ditta costruttrice, che simulava la parte body e la parte head, con due cilindri di 32 e 20 cm rispettivamente. Le misure confermano la riduzione del rumore ma in maniera differente per i diversi filtri di convoluzione utilizzati. Lo studio dell'MTF invece ha rivelato che l'utilizzo delle tecniche standard e iterative non cambia la risoluzione spaziale; infatti gli andamenti ottenuti sono perfettamente identici (a parte le differenze intrinseche nei filtri di convoluzione), a differenza di quanto dichiarato dalla ditta. Per l'analisi del CNR sono stati utilizzati due fantocci; il primo, chiamato Catphan 600 è il fantoccio utilizzato per caratterizzare i sistemi CT. Il secondo, chiamato Cirs 061 ha al suo interno degli inserti che simulano la presenza di lesioni con densità tipiche del distretto addominale. Lo studio effettuato ha evidenziato che, per entrambi i fantocci, il rapporto contrasto-rumore aumenta se si utilizza la tecnica di ricostruzione iterativa. La seconda parte del lavoro di tesi è stata quella di effettuare una valutazione della riduzione della dose prendendo in considerazione diversi protocolli utilizzati nella pratica clinica, si sono analizzati un alto numero di esami e si sono calcolati i valori medi di CTDI e DLP su un campione di esame con FBP e con iDose4. I risultati mostrano che i valori ricavati con l'utilizzo dell'algoritmo iterativo sono al di sotto dei valori DLR nazionali di riferimento e di quelli che non usano i sistemi iterativi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tra le patologie ossee attualmente riconosciute, l’osteoporosi ricopre il ruolo di protagonista data le sua diffusione globale e la multifattorialità delle cause che ne provocano la comparsa. Essa è caratterizzata da una diminuzione quantitativa della massa ossea e da alterazioni qualitative della micro-architettura del tessuto osseo con conseguente aumento della fragilità di quest’ultimo e relativo rischio di frattura. In campo medico-scientifico l’imaging con raggi X, in particolare quello tomografico, da decenni offre un ottimo supporto per la caratterizzazione ossea; nello specifico la microtomografia, definita attualmente come “gold-standard” data la sua elevata risoluzione spaziale, fornisce preziose indicazioni sulla struttura trabecolare e corticale del tessuto. Tuttavia la micro-CT è applicabile solo in-vitro, per cui l’obiettivo di questo lavoro di tesi è quello di verificare se e in che modo una diversa metodica di imaging, quale la cone-beam CT (applicabile invece in-vivo), possa fornire analoghi risultati, pur essendo caratterizzata da risoluzioni spaziali più basse. L’elaborazione delle immagini tomografiche, finalizzata all’analisi dei più importanti parametri morfostrutturali del tessuto osseo, prevede la segmentazione delle stesse con la definizione di una soglia ad hoc. I risultati ottenuti nel corso della tesi, svolta presso il Laboratorio di Tecnologia Medica dell’Istituto Ortopedico Rizzoli di Bologna, mostrano una buona correlazione tra le due metodiche quando si analizzano campioni definiti “ideali”, poiché caratterizzati da piccole porzioni di tessuto osseo di un solo tipo (trabecolare o corticale), incluso in PMMA, e si utilizza una soglia fissa per la segmentazione delle immagini. Diversamente, in casi “reali” (vertebre umane scansionate in aria) la stessa correlazione non è definita e in particolare è da escludere l’utilizzo di una soglia fissa per la segmentazione delle immagini.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis focuses on advanced reconstruction methods and Dual Energy (DE) Computed Tomography (CT) applications for proton therapy, aiming at improving patient positioning and investigating approaches to deal with metal artifacts. To tackle the first goal, an algorithm for post-processing input DE images has been developed. The outputs are tumor- and bone-canceled images, which help in recognising structures in patient body. We proved that positioning error is substantially reduced using contrast enhanced images, thus suggesting the potential of such application. If positioning plays a key role in the delivery, even more important is the quality of planning CT. For that, modern CT scanners offer possibility to tackle challenging cases, like treatment of tumors close to metal implants. Possible approaches for dealing with artifacts introduced by such rods have been investigated experimentally at Paul Scherrer Institut (Switzerland), simulating several treatment plans on an anthropomorphic phantom. In particular, we examined the cases in which none, manual or Iterative Metal Artifact Reduction (iMAR) algorithm were used to correct the artifacts, using both Filtered Back Projection and Sinogram Affirmed Iterative Reconstruction as image reconstruction techniques. Moreover, direct stopping power calculation from DE images with iMAR has also been considered as alternative approach. Delivered dose measured with Gafchromic EBT3 films was compared with the one calculated in Treatment Planning System. Residual positioning errors, daily machine dependent uncertainties and film quenching have been taken into account in the analyses. Although plans with multiple fields seemed more robust than single field, results showed in general better agreement between prescribed and delivered dose when using iMAR, especially if combined with DE approach. Thus, we proved the potential of these advanced algorithms in improving dosimetry for plans in presence of metal implants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Natural stones have been widely used in the construction field since antiquity. Building materials undergo decay processes due to mechanical,chemical, physical and biological causes that can act together. Therefore an interdisciplinary approach is required in order to understand the interaction between the stone and the surrounding environment. Utilization of buildings, inadequate restoration activities and in general anthropogenic weathering factors may contribute to this degradation process. For this reasons, in the last few decades new technologies and techniques have been developed and introduced in the restoration field. Consolidants are largely used in restoration and conservation of cultural heritage in order to improve the internal cohesion and to reduce the weathering rate of building materials. It is important to define the penetration depth of a consolidant for determining its efficacy. Impregnation mainly depends on the microstructure of the stone (i.e. porosity) and on the properties of the product itself. Throughout this study, tetraethoxysilane (TEOS) applied on globigerina limestone samples has been chosen as object of investigation. After hydrolysis and condensation, TEOS deposits silica gel inside the pores, improving the cohesion of the grains. X-ray computed tomography has been used to characterize the internal structure of the limestone samples,treated and untreated with a TEOS-based consolidant. The aim of this work is to investigate the penetration depth and the distribution of the TEOS inside the porosity, using both traditional approaches and advanced X-ray tomographic techniques, the latter allowing the internal visualization in three dimensions of the materials. Fluid transport properties and porosity have been studied both at macroscopic scale, by means of capillary uptake tests and radiography, and at microscopic scale,investigated with X-ray Tomographic Microscopy (XTM). This allows identifying changes in the porosity, by comparison of the images before and after the treatment, and locating the consolidant inside the stone. Tests were initially run at University of Bologna, where characterization of the stone was carried out. Then the research continued in Switzerland: X-ray tomography and radiography were performed at Empa, Swiss Federal Laboratories for Materials Science and Technology, while XTM measurements with synchrotron radiation were run at Paul Scherrer Institute in Villigen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Every year, thousand of surgical treatments are performed in order to fix up or completely substitute, where possible, organs or tissues affected by degenerative diseases. Patients with these kind of illnesses stay long times waiting for a donor that could replace, in a short time, the damaged organ or the tissue. The lack of biological alternates, related to conventional surgical treatments as autografts, allografts, e xenografts, led the researchers belonging to different areas to collaborate to find out innovative solutions. This research brought to a new discipline able to merge molecular biology, biomaterial, engineering, biomechanics and, recently, design and architecture knowledges. This discipline is named Tissue Engineering (TE) and it represents a step forward towards the substitutive or regenerative medicine. One of the major challenge of the TE is to design and develop, using a biomimetic approach, an artificial 3D anatomy scaffold, suitable for cells adhesion that are able to proliferate and differentiate themselves as consequence of the biological and biophysical stimulus offered by the specific tissue to be replaced. Nowadays, powerful instruments allow to perform analysis day by day more accurateand defined on patients that need more precise diagnosis and treatments.Starting from patient specific information provided by TC (Computed Tomography) microCT and MRI(Magnetic Resonance Imaging), an image-based approach can be performed in order to reconstruct the site to be replaced. With the aid of the recent Additive Manufacturing techniques that allow to print tridimensional objects with sub millimetric precision, it is now possible to practice an almost complete control of the parametrical characteristics of the scaffold: this is the way to achieve a correct cellular regeneration. In this work, we focalize the attention on a branch of TE known as Bone TE, whose the bone is main subject. Bone TE combines osteoconductive and morphological aspects of the scaffold, whose main properties are pore diameter, structure porosity and interconnectivity. The realization of the ideal values of these parameters represents the main goal of this work: here we'll a create simple and interactive biomimetic design process based on 3D CAD modeling and generative algorithmsthat provide a way to control the main properties and to create a structure morphologically similar to the cancellous bone. Two different typologies of scaffold will be compared: the first is based on Triply Periodic MinimalSurface (T.P.M.S.) whose basic crystalline geometries are nowadays used for Bone TE scaffolding; the second is based on using Voronoi's diagrams and they are more often used in the design of decorations and jewellery for their capacity to decompose and tasselate a volumetric space using an heterogeneous spatial distribution (often frequent in nature). In this work, we will show how to manipulate the main properties (pore diameter, structure porosity and interconnectivity) of the design TE oriented scaffolding using the implementation of generative algorithms: "bringing back the nature to the nature".

Relevância:

60.00% 60.00%

Publicador:

Resumo:

L’avvento delle tecniche di imaging volumetrico, quali la CT (Computed Tomography) e la MRI (Magnetic Resonance Investigation), ha portato ad un crescente interesse verso applicazioni di guida chirurgica che utilizzano processi di allineamento delle immagini diagnostiche provenienti da diverse modalità e di tecniche che ne permettono la visualizzazione in sala operatoria, in modo da fornire al chirurgo il maggior numero di informazioni cliniche possibili durante un intervento. Il crescente interesse verso questo tipo di applicazioni è dovuto anche allo sviluppo di dispositivi di imaging intra-operatorio quali archi a C-mobili radiologici, PC ad alte prestazioni e convertitori A/D 3D con precisione clinicamente accettabile. Questi ultimi due hanno conseguentemente portato a sviluppare ed implementare software dedicati alla pianificazione di un intervento chirurgico, permettendo quindi di elaborare digitalmente le immagini diagnostiche e ricostruire un modello che rappresenta l’effettiva anatomia del paziente. Questo processo nel suo complesso ha portato allo sviluppo di quelli che oggi vengono chiamati sistemi di navigazione chirurgica, abbreviati talvolta in IGSS (Imaging-Guided Surgery Systems), sistemi ovvero che permettono di utilizzare immagini pre-operatorie come guida durante la pratica chirurgica, caratterizzando quindi nuovi metodi di approccio alla chirurgia, le IGS (Image-Guided Surgery) appunto.