9 resultados para Bio Power Plant

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The current design life of nuclear power plant (NPP) could potentially be extended to 80 years. During this extended plant life, all safety and operationally relevant Instrumentation & Control (I&C) systems are required to meet their designed performance requirements to ensure safe and reliable operation of the NPP, both during normal operation and subsequent to design base events. This in turn requires an adequate and documented qualification and aging management program. It is known that electrical insulation of I&C cables used in safety related circuits can degrade during their life, due to the aging effect of environmental stresses, such as temperature, radiation, vibration, etc., particularly if located in the containment area of the NPP. Thus several condition monitoring techniques are required to assess the state of the insulation. Such techniques can be used to establish a residual lifetime, based on the relationship between condition indicators and ageing stresses, hence, to support a preventive and effective maintenance program. The object of this thesis is to investigate potential electrical aging indicators (diagnostic markers) testing various I&C cable insulations subjected to an accelerated multi-stress (thermal and radiation) aging.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Le microreti caratterizzate da unità di generazione con Fonti Energetiche Rinnovabili (FER), sono oggetto di crescente interesse in due contesti molto diversi tra loro: l’integrazione della Generazione Diffusa (GD) in reti di distribuzione pubbliche nei paesi sviluppati e l’elettrificazione di zone rurali attualmente non servite dalla rete elettrica. L’introduzione dei sistemi di accumulo nelle microreti rende possibile la compensazione della variabilità delle FER trasformando le microreti in sistemi di produzione che nel complesso risultano completamente regolabili. L’obiettivo del presente lavoro di tesi è dimostrare come le microreti possono svolgere un ruolo fondamentale per lo sviluppo delle infrastrutture elettriche nei paesi in via di sviluppo e nelle economie emergenti ponendo le basi per l’elettrificazione di aree remote e scarsamente popolate ad oggi non connesse alla rete di distribuzione dell’energia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Questo elaborato di tesi si concentra sul calcolo delle perdite che si verificano in cavi superconduttori ad alta temperatura critica per la fusione. La valutazione delle perdite riveste un ruolo di particolare importanza nella fase di progettazione di un cavo o di un avvolgimento superconduttore. Infatti, le proprietà superconduttive si manifestano a basse temperature (inferiori alla temperatura di transizione dalla fase normale alla fase superconduttiva) e di conseguenza è necessario configurare un apparato criogenico per il sistema. In tal senso, le perdite rientrano nel “budget” termico necessario a dimensionare correttamente il sistema di raffreddamento. Nel dettaglio, il lavoro verte sulla modellizzazione analitica e numerica delle perdite in una pila di nastri superconduttori in presenza sia di un campo magnetico esterno sia di una corrente di trasporto, entrambi con andamento variabile nel tempo. Gli obiettivi prefissati sono stati raggiunti grazie allo studio della letteratura e alle simulazioni numeriche, effettuate utilizzando dei software commerciali quali COMSOL Multiphysics e Matlab. Il contributo originale di questo elaborato è stato lo sviluppo di un nuovo modello analitico, che permette di calcolare le perdite per isteresi dovute a campi magnetici e correnti variabili periodicamente nel tempo. Le formule hanno carattere generale e possono essere utilizzate quando i campi e le correnti variano in fase seguendo degli andamenti periodici nel tempo di qualsiasi forma. Le simulazioni agli elementi finiti sono servite per validare le formule analitiche proposte. Le nuove relazioni ottenute sono state utilizzate per la stima delle perdite di un inserto ad alta temperatura critica del solenoide centrale di EU-DEMO (DEMOnstration Power Plant). Il modello analitico elaborato sarà pubblicato prossimamente su IEEE-Transactions on Applied Superconductivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The first part of this essay aims at investigating the already available and promising technologies for the biogas and bio-hydrogen production from anaerobic digestion of different organic substrates. One strives to show all the peculiarities of this complicate process, such as continuity, number of stages, moisture, biomass preservation and rate of feeding. The main outcome of this part is the awareness of the huge amount of reactor configurations, each of which suitable for a few types of substrate and circumstance. Among the most remarkable results, one may consider first of all the wet continuous stirred tank reactors (CSTR), right to face the high waste production rate in urbanised and industrialised areas. Then, there is the up-flow anaerobic sludge blanket reactor (UASB), aimed at the biomass preservation in case of highly heterogeneous feedstock, which can also be treated in a wise co-digestion scheme. On the other hand, smaller and scattered rural realities can be served by either wet low-rate digesters for homogeneous agricultural by-products (e.g. fixed-dome) or the cheap dry batch reactors for lignocellulose waste and energy crops (e.g. hybrid batch-UASB). The biological and technical aspects raised during the first chapters are later supported with bibliographic research on the important and multifarious large-scale applications the products of the anaerobic digestion may have. After the upgrading techniques, particular care was devoted to their importance as biofuels, highlighting a further and more flexible solution consisting in the reforming to syngas. Then, one shows the electricity generation and the associated heat conversion, stressing on the high potential of fuel cells (FC) as electricity converters. Last but not least, both the use as vehicle fuel and the injection into the gas pipes are considered as promising applications. The consideration of the still important issues of the bio-hydrogen management (e.g. storage and delivery) may lead to the conclusion that it would be far more challenging to implement than bio-methane, which can potentially “inherit” the assets of the similar fossil natural gas. Thanks to the gathered knowledge, one devotes a chapter to the energetic and financial study of a hybrid power system supplied by biogas and made of different pieces of equipment (natural gas thermocatalitic unit, molten carbonate fuel cell and combined-cycle gas turbine structure). A parallel analysis on a bio-methane-fed CCGT system is carried out in order to compare the two solutions. Both studies show that the apparent inconvenience of the hybrid system actually emphasises the importance of extending the computations to a broader reality, i.e. the upstream processes for the biofuel production and the environmental/social drawbacks due to fossil-derived emissions. Thanks to this “boundary widening”, one can realise the hidden benefits of the hybrid over the CCGT system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last years, the European countries have paid increasing attention to renewable sources and greenhouse emissions. The Council of the European Union and the European Parliament have established ambitious targets for the next years. In this scenario, biomass plays a prominent role since its life cycle produces a zero net carbon dioxide emission. Additionally, biomass can ensure plant operation continuity thanks to its availability and storage ability. Several conventional systems running on biomass are available at the moment. Most of them are performant either in the large-scale or in the small power range. The absence of an efficient system on the small-middle scale inspired this thesis project. The object is an innovative plant based on a wet indirectly fired gas turbine (WIFGT) integrated with an organic Rankine cycle (ORC) unit for combined heat and power production. The WIFGT is a performant system in the small-middle power range; the ORC cycle is capable of giving value to low-temperature heat sources. Their integration is investigated in this thesis with the aim of carrying out a preliminary design of the components. The targeted plant output is around 200 kW in order not to need a wide cultivation area and to avoid biomass shipping. Existing in-house simulation tools are used: They are adapted to this purpose. Firstly the WIFGT + ORC model is built; Zero-dimensional models of heat exchangers, compressor, turbines, furnace, dryer and pump are used. Different fluids are selected but toluene and benzene turn out to be the most suitable. In the indirectly fired gas turbine a pressure ratio around 4 leads to the highest efficiency. From the thermodynamic analysis the system shows an electric efficiency of 38%, outdoing other conventional plants in the same power range. The combined plant is designed to recover thermal energy: Water is used as coolant in the condenser. It is heated from 60°C up to 90°C, ensuring the possibility of space heating. Mono-dimensional models are used to design the heat exchange equipment. Different types of heat exchangers are chosen depending on the working temperature. A finned-plate heat exchanger is selected for the WIFGT heat transfer equipment due to the high temperature, oxidizing and corrosive environment. A once-through boiler with finned tubes is chosen to vaporize the organic fluid in the ORC. A plate heat exchanger is chosen for the condenser and recuperator. A quasi-monodimensional model for single-stage axial turbine is implemented to design both the WIFGT and the ORC turbine. The system simulation after the components design shows an electric efficiency around 34% with a decrease by 10% compared to the zero-dimensional analysis. The work exhibits the system potentiality compared to the existing plants from both technical and economic point of view.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La tesi riguarda lo studio di resine polimeriche derivanti da oli vegetali, impiegabili come leganti nei prodotti vernicianti per l’edilizia ed altri settori. I prodotti vernicianti plant-based sono stati confrontati con altri prodotti attualmente commercializzati, provenienti da fonti fossili. Considerata la produzione ingente dei prodotti vernicianti su base mondiale (8,31 kg/persona) sarebbe determinante impiegare delle fonti rinnovabili per garantirne una produzione sostenibile, diminuendo l’inquinamento, ritardando l’esaurimento del petrolio e riducendo le emissioni di CO2 e di conseguenza l’effetto serra ed il cambiamento climatico. Sono state trattate, quindi, alcune vie di sintesi “green” di leganti poliuretanici ed epossidici per prodotti vernicianti ad elevate prestazioni. Gli oli vegetali sono stati scelti come materie prime in quanto relativamente economici e disponibili in grandi quantità, risultando adatti per produzioni su scala industriale. Sono inoltre riportati i metodi di formulazione di uno smalto opaco bio-based per esterni (ad es. infissi e staccionate) e una vernice opaca per parquet (interni). Le formulazioni sperimentali sono state poi caratterizzate e confrontate con altri prodotti fossil-based presenti in commercio. I prodotti vernicianti sono stati sottoposti a test di brillantezza (gloss), adesione, presa di sporco, durezza, resistenza all’abrasione e resistenza chimica.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hand gesture recognition based on surface electromyography (sEMG) signals is a promising approach for the development of intuitive human-machine interfaces (HMIs) in domains such as robotics and prosthetics. The sEMG signal arises from the muscles' electrical activity, and can thus be used to recognize hand gestures. The decoding from sEMG signals to actual control signals is non-trivial; typically, control systems map sEMG patterns into a set of gestures using machine learning, failing to incorporate any physiological insight. This master thesis aims at developing a bio-inspired hand gesture recognition system based on neuromuscular spike extraction rather than on simple pattern recognition. The system relies on a decomposition algorithm based on independent component analysis (ICA) that decomposes the sEMG signal into its constituent motor unit spike trains, which are then forwarded to a machine learning classifier. Since ICA does not guarantee a consistent motor unit ordering across different sessions, 3 approaches are proposed: 2 ordering criteria based on firing rate and negative entropy, and a re-calibration approach that allows the decomposition model to retain information about previous sessions. Using a multilayer perceptron (MLP), the latter approach results in an accuracy up to 99.4% in a 1-subject, 1-degree of freedom scenario. Afterwards, the decomposition and classification pipeline for inference is parallelized and profiled on the PULP platform, achieving a latency < 50 ms and an energy consumption < 1 mJ. Both the classification models tested (a support vector machine and a lightweight MLP) yielded an accuracy > 92% in a 1-subject, 5-classes (4 gestures and rest) scenario. These results prove that the proposed system is suitable for real-time execution on embedded platforms and also capable of matching the accuracy of state-of-the-art approaches, while also giving some physiological insight on the neuromuscular spikes underlying the sEMG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The market for paint products with raw materials derived from renewable sources is growing rapidly in the building industry. When high performance in wet scrub resistance is required, “washable” paints are used. However, formulating products with Bio-Based raw materials generally results in a decrease in performances compared to similar products with raw materials from fossil sources. Therefore, a new formulation approach is needed to characterize polymeric binders from renewable sources and to consider the synergistic effects given by blends of polymeric binders of different origin and chemical structure. To date, the development of new formulations that imply less environmental impact is necessary if these products have to remain competitive in the marketplace. During the trainingship in IVAS S.p.A., washable paints with different PVC (Pigment Volume Concentration) were formulated and tested, evaluating whether the performance of paints with polymeric binders obtained from renewable sources was comparable to those with polymeric binders from fossil sources. The binders were chemically characterized by DSC, FT-IR and NMR analysis. Characterization tests of paints were focused on the evaluation of degree of whiteness, hiding power, dirt setting, and wet scrub resistance. Following the results obtained from the available binder combinations, it was possible to formulate two washable paints with comparable performances to those from fossil sources: paint A with 20 % of alkydic polymer and 80 % styrene/acrylic polymer and paint B with 40 % of alkydic polymer and 60 % styrene/acrylic polymer. Finally, the formulation was completed by adding the mainly Bio-Based derived additives generally used for this category of paints.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis deals with the sizing and analysis of the electrical power system of a petrochemical plant. The activity was carried out in the framework of an electrical engineering internship. The sizing and electrical calculations, as well as the study of the dynamic behavior of network quantities, are accomplished by using the ETAP (Electrical Transient Analyzer Program) software. After determining the type and size of the loads, the calculation of power flows is carried out for all possible network layout and different power supply configurations. The network is normally operated in a double radial configuration. However, the sizing must be carried out taking into account the most critical configuration, i.e., the temporary one of single radial operation, and also considering the most unfavorable power supply conditions. The calculation of shortcircuit currents is then carried out and the appropriate circuit breakers are selected. Where necessary, capacitor banks are sized in order to keep power factor at the point of common coupling within the preset limits. The grounding system is sized by using the finite element method. For loads with the highest level of criticality, UPS are sized in order to ensure their operation even in the absence of the main power supply. The main faults that can occur in the plant are examined, determining the intervention times of the protections to ensure that, in case of failure on one component, the others can still properly operate. The report concludes with the dynamic and stability analysis of the power system during island operation, in order to ensure that the two gas turbines are able to support the load even during transient conditions.