5 resultados para Acceleration, Centre of mass, Gait, Kinematic, Running, Symmetry

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main purpose of ultrarelativistic heavy-ion collisions is the investigation of the QGP. The ALICE experiment situated at the CERN has been specifically designed to study heavy-ion collisions for centre-of-mass energies up to 5.5 per nucleon pair. Extended particle identification capability is one of the main characteristics of the ALICE experiment. In the intermediate momentum region (up to 2.5 GeV/c for pi/K and 4 GeV/c for K/p), charged particles are identified in the ALICE experiment by the Time of Flight (TOF) detector. The ALICE-TOF system is a large-area detector based on the use of Multi-gap Resistive Plate Chamber (MRPC) built with high efficiency, fast response and intrinsic time resolution better than 40 ps. This thesis work, developed with the ALICE-TOF Bologna group, is part of the efforts carried out to adapt the read-out of the detector to the new requirements after the LHC Long Shutdown 2. Tests on the feasibility of a new read-out scheme for the TOF detector have been performed. In fact, the achievement of a continuous read-out also for the TOF detector would not be affordable if one considers the replacement of the TRM cards both for hardware and budget reasons. Actually, the read-out of the TOF is limited at 250 kHz i.e. it would be able to collect up to just a fourth of the maximum collision rate potentially achievable for pp interactions. In this Master’s degree thesis work, I discuss a different read-out system for the ALICE-TOF detector that allows to register all the hits at the interaction rate of 1 MHz foreseen for pp interactions after the 2020, by using the electronics currently available. Such solution would allow the ALICE-TOF detector to collect all the hits generated by pp collisions at 1 MHz interaction rate, which corresponds to an amount four times larger than that initially expected at such frequencies with the triggered read-out system operated at 250 kHz for LHC Run 3. The obtained results confirm that the proposed read-out scheme is a viable option for the ALICE TOF detector. The results also highlighted that it will be advantageous if the ALICE-TOF group also implement an online monitoring system of noisy channels to allow their deactivation in real time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An industrial manipulator equipped with an automatic clay extruder is used to realize a machine that can manufacture additively clay objects. The desired geometries are designed by means of a 3D modeling software and then sliced in a sequence of layers with the same thickness of the extruded clay section. The profiles of each layer are transformed in trajectories for the extruder and therefore for the end-effector of the manipulator. The goal of this thesis is to improve the algorithm for the inverse kinematic resolution and the integration of the routine within the development software that controls the machine (Rhino/Grasshopper). The kinematic model is described by homogeneous transformations, adopting the Denavit-Hartenberg standard convention. The function is implemented in C# and it has been preliminarily tested in Matlab. The outcome of this work is a substantial reduction of the computation time relative to the execution of the algorithm, which is halved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The t/t production cross section is measured with the CMS detector in the all-jets channel in $pp$ collisions at the centre-of-mass energy of 13 TeV. The analysis is based on the study of t/t events in the boosted topology, namely events in which decay products of the quark top have a high Lorentz boost and are thus reconstructed in the detector as a single, wide jet. The data sample used in this analysis corresponds to an integrated luminosity of 2.53 fb-1. The inclusive cross section is found to be sigma(t/t) = 727 +- 46 (stat.) +115-112 (sys.) +- 20~(lumi.) pb, a value which is consistent with the theoretical predictions. The differential, detector-level cross section is measured as a function of the transverse momentum of the leading jet and compared to the QCD theoretical predictions. Finally, the differential, parton-level cross section is reported, measured as a function of the transverse momentum of the leading parton, extrapolated to the full phase space and compared to the QCD predictions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La massa del quark top è qui misurata per mezzo dei dati raccolti dall’esperimento CMS in collisioni protone-protone ad LHC, con energia nel centro di massa pari ad 8 TeV. Il campione di dati raccolto corrisponde ad una luminosità integrata pari a 18.2 /fb. La misura è effettuata su eventi con un numero di jet almeno pari a 6, di cui almeno due b-taggati (ovvero identificati come prodotto dell’adronizzazione di due quark bottom). Il valore di massa trovato è di (173.95 +- 0.43 (stat)) GeV/c2, in accordo con la media mondiale. The top quark mass is here measured by using the data that have been collected with the CMS experiment in proton-proton collisions at the LHC, at a center-of-mass energy of 8 TeV. The dataset which was used, corresponds to an integrated luminosiy of 18.2 /fb. The mass measurement is carried out by using events characterized by six or more jets, two of which identified as being originated by the hadronization of bottom quarks. The result of the measurement of the top quark mass performed here is: (173.95 +- 0.43 (stat)) GeV/c2, in accordance with the recently published world average.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Groundwater represents one of the most important resources of the world and it is essential to prevent its pollution and to consider remediation intervention in case of contamination. According to the scientific community the characterization and the management of the contaminated sites have to be performed in terms of contaminant fluxes and considering their spatial and temporal evolution. One of the most suitable approach to determine the spatial distribution of pollutant and to quantify contaminant fluxes in groundwater is using control panels. The determination of contaminant mass flux, requires measurement of contaminant concentration in the moving phase (water) and velocity/flux of the groundwater. In this Master Thesis a new solute flux mass measurement approach, based on an integrated control panel type methodology combined with the Finite Volume Point Dilution Method (FVPDM), for the monitoring of transient groundwater fluxes, is proposed. Moreover a new adsorption passive sampler, which allow to capture the variation of solute concentration with time, is designed. The present work contributes to the development of this approach on three key points. First, the ability of the FVPDM to monitor transient groundwater fluxes was verified during a step drawdown test at the experimental site of Hermalle Sous Argentau (Belgium). The results showed that this method can be used, with optimal results, to follow transient groundwater fluxes. Moreover, it resulted that performing FVPDM, in several piezometers, during a pumping test allows to determine the different flow rates and flow regimes that can occurs in the various parts of an aquifer. The second field test aiming to determine the representativity of a control panel for measuring mass flus in groundwater underlined that wrong evaluations of Darcy fluxes and discharge surfaces can determine an incorrect estimation of mass fluxes and that this technique has to be used with precaution. Thus, a detailed geological and hydrogeological characterization must be conducted, before applying this technique. Finally, the third outcome of this work concerned laboratory experiments. The test conducted on several type of adsorption material (Oasis HLB cartridge, TDS-ORGANOSORB 10 and TDS-ORGANOSORB 10-AA), in order to determine the optimum medium to dimension the passive sampler, highlighted the necessity to find a material with a reversible adsorption tendency to completely satisfy the request of the new passive sampling technique.