1000 resultados para indirizzo :: 741 :: Curriculum A: Scienze informatiche
Resumo:
Wireless sensor networks can transform our buildings in smart environments, improving comfort, energy efficiency and safety. Today however, wireless sensor networks are not considered reliable enough for being deployed on large scale. In this thesis, we study the main failure causes for wireless sensor networks, the existing solutions to improve reliability and investigate the possibility to implement self-diagnosis through power consumption measurements on the sensor nodes. Especially, we focus our interest on faults that generate in-range errors: those are wrong readings but belong to the range of the sensor and can therefore be missed by external observers. Using a wireless sensor network deployed in the R\&D building of NXP at the High Tech Campus of Eindhoven, we performed a power consumption characterization of the Wireless Autonomous Sensor (WAS), and studied through some experiments the effect that faults have in the power consumption of the sensor.
Resumo:
Il presente lavoro di tesi, sviluppato nell’arco di sei mesi presso l’Institut Supérieur Industriel de Bruxelles (ISIB) in collaborazione con Ion Beam Application Group (IBA, Louvain la Neuve), ha come principale soggetto lo studio della risposta del rem meter WENDI-2 commercializzato da Thermo Scientific. Lo studio si è basato principalmente sull’uso del codice Monte Carlo MCNPX 2.5.0, simulando la risposta del detector sia in caso di campi di radiazione neutronica monoenergetici sia in corrispondenza di spettri neutronici continui. La prima fase è stata dedicata alla modellizzazione MCNPX del rem counter, consentendo così la valutazione della sua funzione risposta. Questa è stata ricostruita interpolando 93 punti, ciascuno calcolato in corrispondenza di un singolo valore di energia di una sorgente puntiforme, compreso tra 1 meV e 5 GeV. In tal caso è stata rilevata un’ottima corrispondenza tra i risultati ottenuti e quelli riportati nella letteratura scientifica esistente. In una seconda fase, al fine di ottenere informazioni sulla risposta di WENDI II in corrispondenza di campi complessi di radiazione, simulazioni MCNPX sono state realizzate riproducendo un ambiente di lavoro esistente presso la sede IBA di Louvain la Neuve: la risposta del detector è stata valutata in corrispondenza di 9 diverse posizioni all’interno di un bunker contenente un ciclotrone PET (18 MeV H-), implicando la rilevazione di campi di radiazione neutronica continui ed estesi dalle energie termiche fino a 18 MeV. I risultati ottenuti sono stati infine comparati con i valori di dose ambiente equivalente calcolata nelle stesse condizioni di irraggiamento.
Resumo:
Il progetto degli edifici privi di smorzatori viscosi eseguito adottando un fattore di riduzione delle forze R5 (fattore di struttura q del D.M.14/01/08) relativo ad uno smorzamento ξ = 5%, mentre per quelli equipaggiati con smorzatori viscosi il fattore di riduzione delle forze adottato sarà R30 = α R5 relativo ad uno smorzamento ξ = 30%, dove il parametro α è un valore tale da garantire un uguale o maggiore livello di sicurezza della struttura ed è assunto pari a 0,9 da analisi precedenti. Quello che in conclusione si vuole ottenere è che la richiesta di duttilità delle strutture con R30 e ξ = 30% sia minore o uguale di quella richiesta dalle strutture con R5 e ξ = 5%: μd30 ≤ μd5 Durante il percorso di tesi è stata anche valutata una procedura di definizione delle curve di Pushover manuale; la procedura indaga un modo rapido e concettualmente corretto per definire un ordine di grandezza della curva di capacità della struttura.
Resumo:
Slender and lighter footbridges are becoming more and more popular to meet the transportation demand and the aesthetical requirements of the modern society. The widespread presence of such particular structures has become possible thanks to the availability of new, lightweight and still capable of carrying heavy loads material . Therefore, these kind of structure, are particularly sensitive to vibration serviceability problems, especially induced by human activities. As a consequence, it has been imperative to study the dynamic behaviour of such slender pedestrian bridges in order to define their modal characteristics. As an alternative to a Finite Element Analysis to find natural frequencies, damping and mode shape, a so-called Operational Modal Analysis is a valid tool to obtain these parameters through an ambient vibration test. This work provides a useful insight into the Operational Modal Analysis technique and It reports the investigation of the CEME Skywalk, a pedestrian bridge located at the University of British Columbia, in Vancouver, Canada. Furthermore, human-induced vibration tests have been performed and the dynamic characteristics derived with these tests have been compared with the ones from the ambient vibration tests. The effect of the dynamic properties of the two buildings supporting the CEME Skywalk on the dynamic behaviour of the bridge has been also investigated.
Resumo:
Le problematiche ambientali e socio – economiche legate alla costruzione di nuove infrastrutture viarie, impongono la progettazione e costruzione di strade che combinino ad elevati standard prestazionali, la riduzione dell’impatto ambientale in fase realizzativa e manutentiva. Quanto detto avvalora il crescente utilizzo di materiali bituminosi modificati con polimeri ed additivati con cere. I primi conferiscono alla miscela maggiore elastoplasticità, incrementandone la durabilità e la resistenza a fatica. Nei secondi la presenza del materiale paraffinico contribuisce a ridurre la viscosità del bitume, il che consente il notevole abbassamento della temperatura di produzione e stesa della miscela. Numerosi studi inoltre hanno dimostrato che le caratteristiche meccaniche della pavimentazione sono fortemente influenzate dal grado di ossidazione delle componenti organiche del bitume, ovvero dal fenomeno dell’invecchiamento o aging. Risulta pertanto fondamentale affiancare allo studio reologico del bitume, prove di simulazione dell’ invecchiamento nel breve e lungo termine. Nel corso della seguente ricerca si provvederà pertanto ad analizzare leganti modificati ed additivati secondo la teoria della viscoelasticità, simulando le reali condizioni di carico ed invecchiamento alle quali il bitume è sottoposto. Tutte le prove di caratterizzazione reologica avanzata prevederanno l’utilizzo del DSR (Dynamic Shear Rheometer) in varie configurazioni di prova e si simulerà l’invecchiamento a breve termine mediante RTFOT (Rolling thin film oven test). Si proporrà inoltre una nuova procedura di aging invecchiando il bitume alla temperatura di equiviscosità o Twork , ovvero a quel valore della temperatura tale per cui, in fase di messa in opera, si avrà una distribuzione molecolare omogenea del modificante all’interno del bitume. Verranno quindi effettuate ulteriori prove reologiche sui leganti invecchiati a tale temperatura. Si darà infine supporto ai risultati della ricerca effettuando prove chimiche con la tecnica analitica FTIR (Fourier Transform Infrared Spectroscopy), analizzando i cambiamenti molecolari avvenuti nel bitume a seguito dell’aggiunta del modificante e dell’invecchiamento.