25 resultados para Masonry, FRP, fibers
Resumo:
It is well recognized that the technique of strengthening reinforced concrete (RC) using fiber-reinforced polymer (FRP) jackets is more effective for circular sections, but less effective for rectangular sections. Indeed the presence of angular corners does not permit a uniform confinement to be provided by the FRP jackets to the columns. While rounded corners can enhance the effectiveness of FRP confinement, it will be more efficient to modify the rectangular section into an elliptical section. In addition to the better confinement effectiveness, from an aesthetical point of view, the shape modification would be a surprise to the built environment. This paper presents an experimental study on the behavior of FRP-confined concrete columns with elliptical section. Thirty-two short columns, divided in eight batches, were tested under axial compression. Each batch presents four specimens with different elliptical sections, determined by the aspect ratio a/b, that is the ratio between the minor and mayor axis. By varying this value from 1.0 to 2.0 (1.0, 1.3., 1.7, 2.0), the section becomes more and more elliptical starting from a circular shape. In this way it is possible to study the trend of effectiveness of FRP confinement for different section geometries. It is also interesting to study how the confinement effectiveness may vary by changing the cylinder strength of concrete and the number of the layers of CFRP. For this reason, a cylinder strength of concrete of 25 and 45 MPa have been used for the present research work, and half of the specimens were wrapped by one layer of CFRP, while the remaining specimens were wrapped with two layers. A simple analysis of the results has been carried out for evaluating the experimental work described in the present document. Further studies and analysis on this work should help to achieve a new and more accurate stress-strain model for CFRP-confined concrete columns with an elliptical section.
Resumo:
In this work seismic upgrading of existing masonry structures by means of hysteretic ADAS dampers is treated. ADAS are installed on external concrete walls, which are built parallel to the building, and then linked to the building's slab by means of steel rod connection system. In order to assess the effectiveness of the intervention, a parametric study considering variation of damper main features has been conducted. To this aim, the concepts of equivalent linear system (ELS) or equivalent viscous damping are deepen. Simplified equivalent linear model results are then checked respect results of the yielding structures. Two alternative displacement based methods for damper design are herein proposed. Both methods have been validated through non linear time history analyses with spectrum compatible accelerograms. Finally ADAS arrangement for the non conventional implementation is proposed.
Resumo:
Il presente lavoro d tesi si inserisce in un programma di ricerca più esteso mirato ad indagare i meccanismi di distacco tra fibrorinforzati e muratura. L'intera campagna sperimentale si suddivide in prove eseguite per determinare l'influenza del substrato sulla resistenza finale, per individuare l'influenza delle variazioni geometriche degli elementi sul fenomeno del debanding, per confrontare i risultati con i dati ottenuti in altre attività di ricerca.
Resumo:
La presente tesi tratta il comportamento meccanico delle fasce di piano in muratura composite. Con tale termine ci si riferisce alle fasce di piano che hanno al di sotto un elemento portante in conglomerato cementizio armato, come ad esempio cordoli o solai. Assieme ai maschi murari, le fasce di piano costituiscono gli elementi portanti di una parete in muratura. Tuttavia, in caso di analisi sismica di un edificio in muratura, l’effetto fornito da tali elementi è trascurato e si considera solamente il contributo dei maschi murari. Ciò è dovuto anche alla scarsa conoscenza che ancora oggi si possiede sul loro comportamento meccanico. Per questo motivo diversi gruppi di ricerca tutt’ora sono impegnati in tale studio. In particolare, il lavoro di questa tesi, s’inserisce nel più ampio progetto di ricerca condotto dalla professoressa Katrin Beyer, direttrice del Laboratorio di Ingegneria Sismica e Dinamica Strutturale del Politecnico di Losanna (Svizzera).
Resumo:
The assessment of historical structures is a significant need for the next generations, as historical monuments represent the community’s identity and have an important cultural value to society. Most of historical structures built by using masonry which is one of the oldest and most common construction materials used in the building sector since the ancient time. Also it is considered a complex material, as it is a composition of brick units and mortar, which affects the structural performance of the building by having different mechanical behaviour with respect to different geometry and qualities given by the components.
Resumo:
L’aderenza tra barre fibrorinforzate e calcestruzzo è una chiave fondamentale per comprendere al meglio l’azione composita di strutture rinforzate o armate in FRP. Deve essere mobilitata una certa aderenza tra la barra e calcestruzzo per trasferire gli sforzi da un corpo all’altro. Poiché il materiale composito è anisotropo, in direzione longitudinale le proprietà meccaniche sono governate da quelle delle fibre, mentre in direzione trasversale dalla resina. La matrice presenta in genere resistenze più basse di quella a compressione del calcestruzzo, cosicché il meccanismo di aderenza risulta diverso da quello sviluppato dalle tradizionali barre in acciaio. In questa tesi viene sviluppata appunto un’indagine sperimentale sul fenomeno dell’aderenza di barre in acciaio e barre in CFRP (fibra di carbonio) nel calcestruzzo, cercando di capire come cambia il fenomeno al variare dei parametri da cui dipende principalmente l’aderenza, come ad esempio la resistenza caratteristica a compressione del calcestruzzo, il diametro e la deformazione superficiale della barra e la posizione di questa nel provino di calcestruzzo. Sono state quindi realizzate delle prove di pull-out, ovvero delle prove di estrazione di barre da provini di calcestruzzo, per determinare le tensioni tangenziali d’aderenza in funzione dello scorrimento locale della barra (local bond-slip). Infine sono stati calibrati, sui risultati delle prove sperimentali, i tre modelli analitici più noti in letteratura che descrivono il fenomeno dell’aderenza delle barre in FRP nel calcestruzzo, ovvero quello di Malvar (1994), il CMR Model (1995) e il Modified BPE Model (1996).
Resumo:
L'elaborato tratta, inizialmente, delle generalità dei materiali compositi, facendo particolare riferimento agli elementi che contraddistinguono i materiali protagonisti di questa campagna sperimentale (resine epossidiche, fibre, IMR, binder). Successivamente si passa alla trattazione delle varie tecniche usate per produrre un componente in materiale composito, soffermandosi maggiormente sulla tecnica dell’HP-RTM. Inoltre, poichè nell’elaborazione dei risultati ottenuti sono utilizzati curve gaussiane e istogrammi, è inserito un capitolo con informazioni generali sulla statistica e sulle principali distribuzioni di probabilità. Sono, infine, elencati e spiegati i vari materiali utilizzati, con le varie apparecchiature e i due metodi di invecchiamento, igroscopico e termico.