854 resultados para indirizzo :: 790 :: Curriculum D: Fisica della terra


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Large Hadron Collider, located at the CERN laboratories in Geneva, is the largest particle accelerator in the world. One of the main research fields at LHC is the study of the Higgs boson, the latest particle discovered at the ATLAS and CMS experiments. Due to the small production cross section for the Higgs boson, only a substantial statistics can offer the chance to study this particle properties. In order to perform these searches it is desirable to avoid the contamination of the signal signature by the number and variety of the background processes produced in pp collisions at LHC. Much account assumes the study of multivariate methods which, compared to the standard cut-based analysis, can enhance the signal selection of a Higgs boson produced in association with a top quark pair through a dileptonic final state (ttH channel). The statistics collected up to 2012 is not sufficient to supply a significant number of ttH events; however, the methods applied in this thesis will provide a powerful tool for the increasing statistics that will be collected during the next LHC data taking.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il rilascio di detriti d’usura metallici è una grave problematicità connessa ai sistemi protesici, e principalmente riguarda le protesi d’anca ad accoppiamento metallo su metallo in lega CoCr. La presenza di un livello di ioni Co nel siero che supera la soglia di tossicità è correlata a metallosi periprotesica eal fallimento del l’impianto. Recentemente è emersa un’altra casistica, presumibilmente connessa alla distribuzione e accumulo di questi ioni in tessuti di organi anche lontani dall’impianto, che si manifesta con una sintomatologia sistemica analoga a casi noti di avvelenamento da Cobalto. Nel contesto di questa nuova patologia sarebbe di grande interesse la possibilità di monitorare in-vivo la distribuzione del Cobalto rilasciato da protesi articolari, in organi o tessuti di pazienti che manifestano alti ivelli ionici di Co nel siero utilizzando metodiche non invasive come l’NMR. L’ipotesi sperimentale di applicabilità prende spunto dalle proprietà magnetiche che alcuni composti del Cobalto possono presentare nell’organismo. In questo lavoro sperimentale, nato dalla collaborazione tra il laboratorio NMR del DIFA dell’Università di Bologna e l’Istituto Ortopedico Rizzoli (IOR) di Bolgna, si presentano i risultati relativi allo studio di fattibilità condotto con diverse metodiche di rilassometria NMR su campioni biologici in presenza di Co. L’obiettivo riguarda la caratterizzazione delle proprietà di rilassamento con elettromagnete a temperatura ambiente e fisiologica, e la valutazione delle dinamiche molecolari dai profili NMRD ottenuti alle basse frequenze con metodica Fast Field Cycling, dei nuclei 1H di tali sistemi in presenza di Co.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le vene giugulari interne sembrano essere la via principale attraverso cui il sangue defluisce dal cervello verso il cuore, quando siamo in posizione supina. Nel 2008 il professor Paolo Zamboni ha scoperto che una diminuzione dell'attività giugulare può portare allo sviluppo di una condizione emodinamica chiamata CCSVI. Questa può causare ipossia, ritardi nella perfusione cerebrale e riduzione del drenaggio dei cataboliti, oltre ad un'attivazione infiammatoria delle piccole vene e dei tessuti vicini. Questa condizione è stata da subito associata alla sclerosi multipla e su questo argomento si sono dibattuti molti gruppi di ricerca. Inoltre, altre patologie sembrano essere associate alla CCSVI, come il morbo di Parkinson, l'Alzheimer e la sindrome di Meniere. Proprio quest'ultima è uno degli argomenti che attualmente interessa di più il gruppo di lavoro in cui mi sono inserita. Questa patologia comporta problemi uditivi, come sordità e tinnito, vertigini e nausea. Il gruppo Vascolar Disease Center (VDC) dell'Università di Ferrara ha previsto per l'anno 2015 uno studio multicentrico, in cui si cercherà di verificare la correlazione tra CCSVI e sindrome di Meniere. La mia tesi fa parte di un studio preliminare a quello multicentrico. All'inizio del lavoro mi sono dedicata ad un'analisi critica di un modello emodinamico per la quantificazione dei flussi sanguigni: il modello BMC, pubblicato nel 2013 dal gruppo VDC, effettuando in parallelo una ricerca bibliografica sullo stato dell'arte in materia. In seguito ho cominciato a studiare off-line diversi studi patologici e fisiologici, in modo da prendere confidenza con gli strumenti e con le metodologie da utilizzare. Sono stata poi coinvolta dal gruppo VDC per partecipare attivamente al miglioramento del protocollo legato al modello BMC. Infine ho analizzato, con due metodologie differenti, 35 studi effettuati su pazienti otorinolaringoiatrici. Con i risultati ottenuti ho potuto effettuare diverse analisi statistiche al fine di verificare l'equivalenza delle due metodologie. L'obiettivo ultimo era quello di stabilire quale delle due fosse la tecnica migliore da utilizzare, successivamente, nello studio multicentrico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L'obiettivo di questo lavoro di tesi consiste nel progettare, realizzare e testare due collimatori multi-slit da applicare ad un sistema tomografico a raggi X con geometria cone-beam, caratterizzato da un voltaggio massimo di 320 kV. I collimatori che verranno realizzati sono un pre-collimatore e un post-collimatore entrambi multi-slit. Il fine ultimo è quello di riuscire ad avere un sistema di collimazione che permetta attraverso due sole tomografie di ottenere la ricostruzione dell'intero campione. L'abbattimento del tempo necessario per eseguire l'analisi costituisce il target su cui si basa questa tesi. Successivamente sulle immagini prodotte mediante questo nuovo sistema di collimazione saranno condotte delle specifiche analisi e i risultati saranno confrontati con quelli ottenuti mediante un sistema di collimazione a singola fenditura, anch'esso progettato in questa tesi e appositamente realizzato.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performances of the H → ZZ* → 4l analysis are studied in the context of the High Luminosity upgrade of the LHC collider, with the CMS detector. The high luminosity (up to L = 5 × 10^34 cm−2s−1) of the accelerator poses very challenging experimental con- ditions. In particular, the number of overlapping events per bunch crossing will increase to 140. To cope with this difficult environment, the CMS detector will be upgraded in two stages: Phase-I and Phase-II. The tools used in the analysis are the CMS Full Simulation and the fast parametrized Delphes simulation. A validation of Delphes with respect to the Full Simulation is performed, using reference Phase-I detector samples. Delphes is then used to simulate the Phase-II detector response. The Phase-II configuration is compared with the Phase-I detector and the same Phase-I detector affected by aging processes, both modeled with the Full Simulation framework. Conclusions on these three scenarios are derived: the degradation in performances observed with the “aged” scenario shows that a major upgrade of the detector is mandatory. The specific upgrade configuration studied allows to keep the same performances as in Phase-I and, in the case of the four-muons channel, even to exceed them.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In questo elaborato, abbiamo tentato di modellizzare i processi che regolano la presenza dei domini proteici. I domini proteici studiati in questa tesi sono stati ottenuti dai genomi batterici disponibili nei data base pubblici (principalmente dal National Centre for Biotechnology Information: NCBI) tramite una procedura di simulazione computazionale. Ci siamo concentrati su organismi batterici in quanto in essi la presenza di geni trasmessi orizzontalmente, ossia che parte del materiale genetico non provenga dai genitori, e assodato che sia presente in una maggiore percentuale rispetto agli organismi più evoluti. Il modello usato si basa sui processi stocastici di nascita e morte, con l'aggiunta di un parametro di migrazione, usato anche nella descrizione dell'abbondanza relativa delle specie in ambito delle biodiversità ecologiche. Le relazioni tra i parametri, calcolati come migliori stime di una distribuzione binomiale negativa rinormalizzata e adattata agli istogrammi sperimentali, ci induce ad ipotizzare che le famiglie batteriche caratterizzate da un basso valore numerico del parametro di immigrazione abbiano contrastato questo deficit con un elevato valore del tasso di nascita. Al contrario, ipotizziamo che le famiglie con un tasso di nascita relativamente basso si siano adattate, e in conseguenza, mostrano un elevato valore del parametro di migrazione. Inoltre riteniamo che il parametro di migrazione sia direttamente proporzionale alla quantità di trasferimento genico orizzontale effettuato dalla famiglia batterica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Negli anni recenti, lo sviluppo dell’elettronica organica ha condotto all’impiego di materiali organici alla base di numerosi dispositivi elettronici, quali i diodi ad emissione di luce, i transistor ad effetto di campo, le celle solari e i rivelatori di radiazione. Riguardo quest’ultimi, gli studi riportati in letteratura si riferiscono per la maggiore a dispositivi basati su materiali organici a film sottile, che tuttavia presentano problemi relativi ad instabilità e degradazione. Come verrà illustrato, l’impiego di singoli cristalli organici come materiali alla base di questi dispositivi permette il superamento delle principali limitazioni che caratterizzano i rivelatori basati su film sottili. In questa attività sperimentale, dispositivi basati su cristalli organici semiconduttori verranno caratterizzati in base alle principali figure di merito dei rivelatori. Tra i campioni testati, alcuni dispositivi basati su singoli cristalli di 6,13-bis (triisopropylsilylethynyl)-pentacene (TIPS-Pentacene) e 5,6,11,12-tetraphenyltetracene (Rubrene) hanno mostrato interessanti proprietà e sono stati quindi maggiormente studiati.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The problem of localizing a scatterer, which represents a tumor, in a homogeneous circular domain, which represents a breast, is addressed. A breast imaging method based on microwaves is considered. The microwave imaging involves to several techniques for detecting, localizing and characterizing tumors in breast tissues. In all such methods an electromagnetic inverse scattering problem exists. For the scattering detection method, an algorithm based on a linear procedure solution, inspired by MUltiple SIgnal Classification algorithm (MUSIC) and Time Reversal method (TR), is implemented. The algorithm returns a reconstructed image of the investigation domain in which it is detected the scatterer position. This image is called pseudospectrum. A preliminary performance analysis of the algorithm vying the working frequency is performed: the resolution and the signal-to-noise ratio of the pseudospectra are improved if a multi-frequency approach is considered. The Geometrical Mean-MUSIC algorithm (GM- MUSIC) is proposed as multi-frequency method. The performance of the GMMUSIC is tested in different real life computer simulations. The performed analysis shows that the algorithm detects the scatterer until the electrical parameters of the breast are known. This is an evident limit, since, in a real life situation, the anatomy of the breast is unknown. An improvement in GM-MUSIC is proposed: the Eye-GMMUSIC algorithm. Eye-GMMUSIC algorithm needs no a priori information on the electrical parameters of the breast. It is an optimizing algorithm based on the pattern search algorithm: it searches the breast parameters which minimize the Signal-to-Clutter Mean Ratio (SCMR) in the signal. Finally, the GM-MUSIC and the Eye-GMMUSIC algorithms are tested on a microwave breast cancer detection system consisting of an dipole antenna, a Vector Network Analyzer and a novel breast phantom built at University of Bologna. The reconstruction of the experimental data confirm the GM-MUSIC ability to localize a scatterer in a homogeneous medium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays, data handling and data analysis in High Energy Physics requires a vast amount of computational power and storage. In particular, the world-wide LHC Com- puting Grid (LCG), an infrastructure and pool of services developed and deployed by a ample community of physicists and computer scientists, has demonstrated to be a game changer in the efficiency of data analyses during Run-I at the LHC, playing a crucial role in the Higgs boson discovery. Recently, the Cloud computing paradigm is emerging and reaching a considerable adoption level by many different scientific organizations and not only. Cloud allows to access and utilize not-owned large computing resources shared among many scientific communities. Considering the challenging requirements of LHC physics in Run-II and beyond, the LHC computing community is interested in exploring Clouds and see whether they can provide a complementary approach - or even a valid alternative - to the existing technological solutions based on Grid. In the LHC community, several experiments have been adopting Cloud approaches, and in particular the experience of the CMS experiment is of relevance to this thesis. The LHC Run-II has just started, and Cloud-based solutions are already in production for CMS. However, other approaches of Cloud usage are being thought of and are at the prototype level, as the work done in this thesis. This effort is of paramount importance to be able to equip CMS with the capability to elastically and flexibly access and utilize the computing resources needed to face the challenges of Run-III and Run-IV. The main purpose of this thesis is to present forefront Cloud approaches that allow the CMS experiment to extend to on-demand resources dynamically allocated as needed. Moreover, a direct access to Cloud resources is presented as suitable use case to face up with the CMS experiment needs. Chapter 1 presents an overview of High Energy Physics at the LHC and of the CMS experience in Run-I, as well as preparation for Run-II. Chapter 2 describes the current CMS Computing Model, and Chapter 3 provides Cloud approaches pursued and used within the CMS Collaboration. Chapter 4 and Chapter 5 discuss the original and forefront work done in this thesis to develop and test working prototypes of elastic extensions of CMS computing resources on Clouds, and HEP Computing “as a Service”. The impact of such work on a benchmark CMS physics use-cases is also demonstrated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis is aimed to assess similarities and mismatches between the outputs from two independent methods for the cloud cover quantification and classification based on quite different physical basis. One of them is the SAFNWC software package designed to process radiance data acquired by the SEVIRI sensor in the VIS/IR. The other is the MWCC algorithm, which uses the brightness temperatures acquired by the AMSU-B and MHS sensors in their channels centered in the MW water vapour absorption band. At a first stage their cloud detection capability has been tested, by comparing the Cloud Masks they produced. These showed a good agreement between two methods, although some critical situations stand out. The MWCC, in effect, fails to reveal clouds which according to SAFNWC are fractional, cirrus, very low and high opaque clouds. In the second stage of the inter-comparison the pixels classified as cloudy according to both softwares have been. The overall observed tendency of the MWCC method, is an overestimation of the lower cloud classes. Viceversa, the more the cloud top height grows up, the more the MWCC not reveal a certain cloud portion, rather detected by means of the SAFNWC tool. This is what also emerges from a series of tests carried out by using the cloud top height information in order to evaluate the height ranges in which each MWCC category is defined. Therefore, although the involved methods intend to provide the same kind of information, in reality they return quite different details on the same atmospheric column. The SAFNWC retrieval being very sensitive to the top temperature of a cloud, brings the actual level reached by this. The MWCC, by exploiting the capability of the microwaves, is able to give an information about the levels that are located more deeply within the atmospheric column.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il presente lavoro di tesi si inserisce all'interno di uno studio dal titolo: "Strategia di posizionamento multi-step come approccio pragmatico per ridurre il rischio di encefalopatia epatica post-TIPS (shunt trans-giugulare porto-sistemico intraepatico) in pazienti cirrotici con ascite refrattaria". Il progetto di tesi si è concentrato sull'analisi dei segnali ottenuti tramite DCE MRI, con lo scopo di implementare in ambiente MatLab due modelli differenti (Dual input - Mono compartment e Dual input - Dual compartment) che descrivono la cinetica del tracciante all'interno del sistema vascolare epatico e valutare l'efficacia dei parametri di perfusione associati nella descrizione delle variazioni in termini di microcircolazione introdotte dall'inserimento del TIPS. Inizialmente si sono voluti valutare, tramite simulazione, gli effetti in termini di amplificazione del rumore e stima dei parametri perfusionali dell'approssimazione lineare nella conversione da intensità di segnale MR a concentrazione di mezzo di contrasto. Successivamente, sempre attraverso simulazioni, per entrambi i modelli considerati è stato scelto uno schema di model-fitting e quindi testata l'affidabilità in termini di accuratezza e precisione delle stime dei parametri ottenute in funzione del livello di rumore associato alle curve di intensità di segnale. Parallelamente all'implementazione dei modelli per la stima di parametri di perfusione, sono stati realizzati dei phantom con l'obiettivo di simulare il parenchima epatico prima e dopo l'arrivo del mezzo di contrasto e poter testare la sequenza utilizzata durante l'acquisizione dei dati su paziente. Infine sono stati considerati gli esami di DCE MRI effettuati su un campione di nove pazienti pre e post-TIPS, utilizzando per l'analisi dei segnali entrambi i modelli implementati in fase di simulazione e successivamente valutando le variazioni nel valori associati ai parametri di perfusione introdotte dall'inserimento del TIPS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main purpose of ultrarelativistic heavy-ion collisions is the investigation of the QGP. The ALICE experiment situated at the CERN has been specifically designed to study heavy-ion collisions for centre-of-mass energies up to 5.5 per nucleon pair. Extended particle identification capability is one of the main characteristics of the ALICE experiment. In the intermediate momentum region (up to 2.5 GeV/c for pi/K and 4 GeV/c for K/p), charged particles are identified in the ALICE experiment by the Time of Flight (TOF) detector. The ALICE-TOF system is a large-area detector based on the use of Multi-gap Resistive Plate Chamber (MRPC) built with high efficiency, fast response and intrinsic time resolution better than 40 ps. This thesis work, developed with the ALICE-TOF Bologna group, is part of the efforts carried out to adapt the read-out of the detector to the new requirements after the LHC Long Shutdown 2. Tests on the feasibility of a new read-out scheme for the TOF detector have been performed. In fact, the achievement of a continuous read-out also for the TOF detector would not be affordable if one considers the replacement of the TRM cards both for hardware and budget reasons. Actually, the read-out of the TOF is limited at 250 kHz i.e. it would be able to collect up to just a fourth of the maximum collision rate potentially achievable for pp interactions. In this Master’s degree thesis work, I discuss a different read-out system for the ALICE-TOF detector that allows to register all the hits at the interaction rate of 1 MHz foreseen for pp interactions after the 2020, by using the electronics currently available. Such solution would allow the ALICE-TOF detector to collect all the hits generated by pp collisions at 1 MHz interaction rate, which corresponds to an amount four times larger than that initially expected at such frequencies with the triggered read-out system operated at 250 kHz for LHC Run 3. The obtained results confirm that the proposed read-out scheme is a viable option for the ALICE TOF detector. The results also highlighted that it will be advantageous if the ALICE-TOF group also implement an online monitoring system of noisy channels to allow their deactivation in real time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis work aims to find a procedure for isolating specific features of the current signal from a plasma focus for medical applications. The structure of the current signal inside a plasma focus is exclusive of this class of machines and a specific analysis procedure has to be developed. The hope is to find one or more features that shows a correlation with the dose erogated. The study of the correlation between the current discharge signal and the dose delivered by a plasma focus could be of some importance not only for the practical application of dose prediction but also for expanding the knowledge anbout the plasma focus physics. Vatious classes of time-frequency analysis tecniques are implemented in order to solve the problem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The morphological and functional unit of all the living organisms is the cell. The transmembrane proteins, localized in the plasma membrane of cells, play a key role in the survival of the cells themselves. These proteins perform a variety of different tasks, for example the control of the homeostasis. In order to control the homeostasis, these proteins have to regulate the concentration of chemical elements, like ions, inside and outside the cell. These regulations are fundamental for the survival of the cell and to understand them we need to understand how transmembrane proteins work. Two of the most important categories of transmembrane proteins are ion channels and transporter proteins. The ion channels have been depth studied at the single molecule level since late 1970s with the development of patch-clamp technique. It is not possible to apply this technique to study the transporter proteins so a new technique is under development in order to investigate the behavior of transporter proteins at the single molecule level. This thesis describes the development of a nanoscale single liposome assay for functional studies of transporter proteins based on quantitative fluorescence microscopy in a highly-parallel manner and in real time. The transporter of interest is the prokaryotic transporter Listeria Monocytogenes Ca2+-ATPase1 (LMCA1), a structural analogue of the eukaryotic calcium pumps SERCA and PMCA. This technique will allow the characterization of LMCA1 functionality at the single molecule level. Three systematically characterized fluorescent sensors were tested at the single liposome scale in order to investigate if their properties are suitable to study the function of the transporter of interest. Further studies will be needed in order to characterize the selected calcium sensor and pH sensor both implemented together in single liposomes and in presence of the reconstituted protein LMCA1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Organic semiconductor technology has attracted considerable research interest in view of its great promise for large area, lightweight, and flexible electronics applications. Owing to their advantages in processing and unique physical properties, organic semiconductors can bring exciting new opportunities for broad-impact applications requiring large area coverage, mechanical flexibility, low-temperature processing, and low cost. In order to achieve highly flexible device architecture it is crucial to understand on a microscopic scale how mechanical deformation affects the electrical performance of organic thin film devices. Towards this aim, I established in this thesis the experimental technique of Kelvin Probe Force Microscopy (KPFM) as a tool to investigate the morphology and the surface potential of organic semiconducting thin films under mechanical strain. KPFM has been employed to investigate the strain response of two different Organic Thin Film Transistor with active layer made by 6,13-bis(triisopropylsilylethynyl)-pentacene (TIPS-Pentacene), and Poly(3-hexylthiophene-2,5-diyl) (P3HT). The results show that this technique allows to investigate on a microscopic scale failure of flexible TFT with this kind of materials during bending. I find that the abrupt reduction of TIPS-pentacene device performance at critical bending radii is related to the formation of nano-cracks in the microcrystal morphology, easily identified due to the abrupt variation in surface potential caused by local increase in resistance. Numerical simulation of the bending mechanics of the transistor structure further identifies the mechanical strain exerted on the TIPS-pentacene micro-crystals as the fundamental origin of fracture. Instead for P3HT based transistors no significant reduction in electrical performance is observed during bending. This finding is attributed to the amorphous nature of the polymer giving rise to an elastic response without the occurrence of crack formation.