4 resultados para power position
em AMS Tesi di Dottorato - Alm@DL - Universit
Resumo:
There have been almost fifty years since Harry Eckstein' s classic monograph, A Theory of Stable Democracy (Princeton, 1961), where he sketched out the basic tenets of the “congruence theory”, which was to become one of the most important and innovative contributions to understanding democratic rule. His next work, Division and Cohesion in Democracy, (Princeton University Press: 1966) is designed to serve as a plausibility probe for this 'theory' (ftn.) and is a case study of a Northern democratic system, Norway. What is more, this line of his work best exemplifies the contribution Eckstein brought to the methodology of comparative politics through his seminal article, “ “Case Study and Theory in Political Science” ” (in Greenstein and Polsby, eds., Handbook of Political Science, 1975), on the importance of the case study as an approach to empirical theory. This article demonstrates the special utility of “crucial case studies” in testing theory, thereby undermining the accepted wisdom in comparative research that the larger the number of cases the better. Although not along the same lines, but shifting the case study unit of research, I intend to take up here the challenge and build upon an equally unique political system, the Swedish one. Bearing in mind the peculiarities of the Swedish political system, my unit of analysis is going to be further restricted to the Swedish Social Democratic Party, the Svenska Arbetare Partiet. However, my research stays within the methodological framework of the case study theory inasmuch as it focuses on a single political system and party. The Swedish SAP endurance in government office and its electoral success throughout half a century (ftn. As of the 1991 election, there were about 56 years - more than half century - of interrupted social democratic "reign" in Sweden.) are undeniably a performance no other Social Democrat party has yet achieved in democratic conditions. Therefore, it is legitimate to inquire about the exceptionality of this unique political power combination. Which were the different components of this dominance power position, which made possible for SAP's governmental office stamina? I will argue here that it was the end-product of a combination of multifarious factors such as a key position in the party system, strong party leadership and organization, a carefully designed strategy regarding class politics and welfare policy. My research is divided into three main parts, the historical incursion, the 'welfare' part and the 'environment' part. The first part is a historical account of the main political events and issues, which are relevant for my case study. Chapter 2 is devoted to the historical events unfolding in the 1920-1960 period: the Saltsjoebaden Agreement, the series of workers' strikes in the 1920s and SAP's inception. It exposes SAP's ascent to power in the mid 1930s and the party's ensuing strategies for winning and keeping political office, that is its economic program and key economic goals. The following chapter - chapter 3 - explores the next period, i.e. the period from 1960s to 1990s and covers the party's troubled political times, its peak and the beginnings of the decline. The 1960s are relevant for SAP's planning of a long term economic strategy - the Rehn Meidner model, a new way of macroeconomic steering, based on the Keynesian model, but adapted to the new economic realities of welfare capitalist societies. The second and third parts of this study develop several hypotheses related to SAP's 'dominant position' (endurance in politics and in office) and test them afterwards. Mainly, the twin issues of economics and environment are raised and their political relevance for the party analyzed. On one hand, globalization and its spillover effects over the Swedish welfare system are important causal factors in explaining the transformative social-economic challenges the party had to put up with. On the other hand, Europeanization and environmental change influenced to a great deal SAP's foreign policy choices and its domestic electoral strategies. The implications of globalization on the Swedish welfare system will make the subject of two chapters - chapters four and five, respectively, whereupon the Europeanization consequences will be treated at length in the third part of this work - chapters six and seven, respectively. Apparently, at first sight, the link between foreign policy and electoral strategy is difficult to prove and uncanny, in the least. However, in the SAP's case there is a bulk of literature and public opinion statistical data able to show that governmental domestic policy and party politics are in a tight dependence to foreign policy decisions and sovereignty issues. Again, these country characteristics and peculiar causal relationships are outlined in the first chapters and explained in the second and third parts. The sixth chapter explores the presupposed relationship between Europeanization and environmental policy, on one hand, and SAP's environmental policy formulation and simultaneous agenda-setting at the international level, on the other hand. This chapter describes Swedish leadership in environmental policy formulation on two simultaneous fronts and across two different time spans. The last chapter, chapter eight - while trying to develop a conclusion, explores the alternative theories plausible in explaining the outlined hypotheses and points out the reasons why these theories do not fit as valid alternative explanation to my systemic corporatism thesis as the main causal factor determining SAP's 'dominant position'. Among the alternative theories, I would consider Traedgaardh L. and Bo Rothstein's historical exceptionalism thesis and the public opinion thesis, which alone are not able to explain the half century social democratic endurance in government in the Swedish case.
Resumo:
The research activity carried out during the PhD course in Electrical Engineering belongs to the branch of electric and electronic measurements. The main subject of the present thesis is a distributed measurement system to be installed in Medium Voltage power networks, as well as the method developed to analyze data acquired by the measurement system itself and to monitor power quality. In chapter 2 the increasing interest towards power quality in electrical systems is illustrated, by reporting the international research activity inherent to the problem and the relevant standards and guidelines emitted. The aspect of the quality of voltage provided by utilities and influenced by customers in the various points of a network came out only in recent years, in particular as a consequence of the energy market liberalization. Usually, the concept of quality of the delivered energy has been associated mostly to its continuity. Hence the reliability was the main characteristic to be ensured for power systems. Nowadays, the number and duration of interruptions are the “quality indicators” commonly perceived by most customers; for this reason, a short section is dedicated also to network reliability and its regulation. In this contest it should be noted that although the measurement system developed during the research activity belongs to the field of power quality evaluation systems, the information registered in real time by its remote stations can be used to improve the system reliability too. Given the vast scenario of power quality degrading phenomena that usually can occur in distribution networks, the study has been focused on electromagnetic transients affecting line voltages. The outcome of such a study has been the design and realization of a distributed measurement system which continuously monitor the phase signals in different points of a network, detect the occurrence of transients superposed to the fundamental steady state component and register the time of occurrence of such events. The data set is finally used to locate the source of the transient disturbance propagating along the network lines. Most of the oscillatory transients affecting line voltages are due to faults occurring in any point of the distribution system and have to be seen before protection equipment intervention. An important conclusion is that the method can improve the monitored network reliability, since the knowledge of the location of a fault allows the energy manager to reduce as much as possible both the area of the network to be disconnected for protection purposes and the time spent by technical staff to recover the abnormal condition and/or the damage. The part of the thesis presenting the results of such a study and activity is structured as follows: chapter 3 deals with the propagation of electromagnetic transients in power systems by defining characteristics and causes of the phenomena and briefly reporting the theory and approaches used to study transients propagation. Then the state of the art concerning methods to detect and locate faults in distribution networks is presented. Finally the attention is paid on the particular technique adopted for the same purpose during the thesis, and the methods developed on the basis of such approach. Chapter 4 reports the configuration of the distribution networks on which the fault location method has been applied by means of simulations as well as the results obtained case by case. In this way the performance featured by the location procedure firstly in ideal then in realistic operating conditions are tested. In chapter 5 the measurement system designed to implement the transients detection and fault location method is presented. The hardware belonging to the measurement chain of every acquisition channel in remote stations is described. Then, the global measurement system is characterized by considering the non ideal aspects of each device that can concur to the final combined uncertainty on the estimated position of the fault in the network under test. Finally, such parameter is computed according to the Guide to the Expression of Uncertainty in Measurements, by means of a numeric procedure. In the last chapter a device is described that has been designed and realized during the PhD activity aiming at substituting the commercial capacitive voltage divider belonging to the conditioning block of the measurement chain. Such a study has been carried out aiming at providing an alternative to the used transducer that could feature equivalent performance and lower cost. In this way, the economical impact of the investment associated to the whole measurement system would be significantly reduced, making the method application much more feasible.
Resumo:
In the context of “testing laboratory” one of the most important aspect to deal with is the measurement result. Whenever decisions are based on measurement results, it is important to have some indication of the quality of the results. In every area concerning with noise measurement many standards are available but without an expression of uncertainty, it is impossible to judge whether two results are in compliance or not. ISO/IEC 17025 is an international standard related with the competence of calibration and testing laboratories. It contains the requirements that testing and calibration laboratories have to meet if they wish to demonstrate that they operate to a quality system, are technically competent and are able to generate technically valid results. ISO/IEC 17025 deals specifically with the requirements for the competence of laboratories performing testing and calibration and for the reporting of the results, which may or may not contain opinions and interpretations of the results. The standard requires appropriate methods of analysis to be used for estimating uncertainty of measurement. In this point of view, for a testing laboratory performing sound power measurement according to specific ISO standards and European Directives, the measurement of uncertainties is the most important factor to deal with. Sound power level measurement, according to ISO 3744:1994 , performed with a limited number of microphones distributed over a surface enveloping a source is affected by a certain systematic error and a related standard deviation. Making a comparison of measurement carried out with different microphone arrays is difficult because results are affected by systematic errors and standard deviation that are peculiarities of the number of microphones disposed on the surface, their spatial position and the complexity of the sound field. A statistical approach could give an overview of the difference between sound power level evaluated with different microphone arrays and an evaluation of errors that afflict this kind of measurement. Despite the classical approach that tend to follow the ISO GUM this thesis present a different point of view of the problem related to the comparison of result obtained from different microphone arrays.
Resumo:
In the frame of inductive power transfer (IPT) systems, arrays of magnetically coupled resonators have received increasing attention as they are cheap and versatile due to their simple structure. They consist of magnetically coupled coils, which resonate with their self-capacitance or lumped capacitive networks. Of great industrial interest are planar resonator arrays used to power a receiver that can be placed at any position above the array. A thorough circuit analysis has been carried out, first starting from traditional two-coil IPT devices. Then, resonator arrays have been introduced, with particular attention to the case of arrays with a receiver. To evaluate the system performance, a circuit model based on original analytical formulas has been developed and experimentally validated. The results of the analysis also led to the definition of a new doubly-fed array configuration with a receiver that can be placed above it at any position. A suitable control strategy aimed at maximising the transmitted power and the efficiency has been also proposed. The study of the array currents has been carried out resorting to the theory of magneto-inductive waves, allowing useful insight to be highlighted. The analysis has been completed with a numerical and experimental study on the magnetic field distribution originating from the array. Furthermore, an application of the resonator array as a position sensor has been investigated. The position of the receiver is estimated through the measurement of the array input impedance, for which an original analytical expression has been also obtained. The application of this sensing technique in an automotive dynamic IPT system has been discussed. The thesis concludes with an evaluation of the possible applications of two-dimensional resonator arrays in IPT systems. These devices can be used to improve system efficiency and transmitted power, as well as for magnetic field shielding.