9 resultados para ultrasound ct
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
Background: Congenital cytomegalovirus (CMV) infection may lead to cerebral injury and neurodevelopmental delay. Cranial computed tomography (CT) is currently the standard imaging technique for predicting the outcome of CMV infected patients. Ultrasound (US) is a safe means to assess the extent of cerebral injury due to CMV infection in neonates, and unlike CT, is readily available at the bedside. Aim: To report the accuracy of US in predicting neurodevelopmental and sensorineural outcome in patients with congenital CMV infection. Study design: 57 newborns with congenital CMV infection underwent brain US and were followed prospectively for motor skills, developmental quotient and hearing function. Results: An abnormal US was found in 12/57 newborns. At least one sequela (Developmental Quotient < 85, motor delay, sensorineural hearing loss) was present in 10/11 surviving children with abnormal US (1 patient died in the neonatal period) vs 3/45 newborns with normal US (OR for death or poor outcome: 154, CI 17.3-1219.6, p<0.001, positive predictive value 91.7%, negative predictive value 93.3%). Conclusion: A good correlation is shown between ultrasound abnormalities and the prediction of outcome, suggesting that US may be used to study and follow CMV infected neonates. Our findings await confirmation in a larger population.
Resumo:
Aim: To evaluate the early response to treatment to an antiangiogenetic drug (sorafenib) in a heterotopic murine model of hepatocellular carcinoma (HCC) using ultrasonographic molecular imaging. Material and Methods: the xenographt model was established injecting a suspension of HuH7 cells subcutaneously in 19 nude mice. When tumors reached a mean diameter of 5-10 mm, they were divided in two groups (treatment and vehicle). The treatment group received sorafenib (62 mg/kg) by daily oral gavage for 14 days. Molecular imaging was performed using contrast enhanced ultrasound (CEUS), by injecting into the mouse venous circulation a suspension of VEGFR-2 targeted microbubbles (BR55, kind gift of Bracco Swiss, Geneve, Switzerland). Video clips were acquired for 6 minutes, then microbubbles (MBs) were destroyed by a high mechanical index (MI) impulse, and another minute was recorded to evaluate residual circulating MBs. The US protocol was repeated at day 0,+2,+4,+7, and +14 from the beginning of treatment administration. Video clips were analyzed using a dedicated software (Sonotumor, Bracco Swiss) to quantify the signal of the contrast agent. Time/intensity curves were obtained and the difference of the mean MBs signal before and after high MI impulse (Differential Targeted Enhancement-dTE) was calculated. dTE represents a numeric value in arbitrary units proportional to the amount of bound MBs. At day +14 mice were euthanized and the tumors analyzed for VEGFR-2, pERK, and CD31 tissue levels using western blot analysis. Results: dTE values decreased from day 0 to day +14 both in treatment and vehicle groups, and they were statistically higher in vehicle group than in treatment group at day +2, at day +7, and at day +14. With respect to the degree of tumor volume increase, measured as growth percentage delta (GPD), treatment group was divided in two sub-groups, non-responders (GPD>350%), and responders (GPD<200%). In the same way vehicle group was divided in slow growth group (GPD<400%), and fast growth group (GPD>900%). dTE values at day 0 (immediately before treatment start) were higher in non-responders than in responders group, with statistical difference at day 2. While dTE values were higher in the fast growth group than in the slow growth group only at day 0. A significant positive correlation was found between VEGFR-2 tissue levels and dTE values, confirming that level of BR55 tissue enhancement reflects the amount of tissue VEGF receptor. Conclusions: the present findings show that, at least in murine experimental models, CEUS with BR55 is feasable and appears to be a useful tool in the prediction of tumor growth and response to sorafenib treatment in xenograft HCC.
Resumo:
In this thesis two major topics inherent with medical ultrasound images are addressed: deconvolution and segmentation. In the first case a deconvolution algorithm is described allowing statistically consistent maximum a posteriori estimates of the tissue reflectivity to be restored. These estimates are proven to provide a reliable source of information for achieving an accurate characterization of biological tissues through the ultrasound echo. The second topic involves the definition of a semi automatic algorithm for myocardium segmentation in 2D echocardiographic images. The results show that the proposed method can reduce inter- and intra observer variability in myocardial contours delineation and is feasible and accurate even on clinical data.
Resumo:
Introduction Lower pole kidney stones represent at time a challenge for the urologist. The gold standard treatment for intrarenal stones <2 cm is Extracorporeal Shock Wave Lithotripsy (ESWL) while for those >2 cm is Percutaneous Nephrolithotomy (PCNL). The success rate of ESWL, however, decreases when it is employed for lower pole stones, and this is particularly true in the presence of narrow calices or acute infundibular angles. Studies have proved that ureteroscopy (URS) is an efficacious alternative to ESWL for lower pole stones <2 cm, but this is not reflected by either the European or the American guidelines. The aim of this study is to present the results of a large series of flexible ureteroscopies and PCNLs for lower pole kidney stones from high-volume centers, in order to provide more evidences on the potential indications of the flexible ureteroscopy for the treatment of kidney stones. Materials and Methods A database was created and the participating centres retrospectively entered their data relating to the percutaneous and flexible ureteroscopic management of lower pole kidney stones. Patients included were treated between January 2005 and January 2010. Variables analyzed included case load number, preoperative and postoperative imaging, stone burden, anaesthesia (general vs. spinal), type of lithotripter, access location and size, access dilation type, ureteral access sheath use, visual clarity, operative time, stone-free rate, complication rate, hospital stay, analgesic requirement and follow-up time. Stone-free rate was defined as absence of residual fragments or presence of a single fragment <2 mm in size at follow-up imaging. Primary end-point was to test the efficacy and safety of flexible URS for the treatment of lower pole stones; the same descriptive analysis was conducted for the PCNL approach, as considered the gold standard for the treatment of lower pole kidney stones. In this setting, no statistical analysis was conducted owing to the different selection criteria of the patients. Secondary end-point consisted in matching the results of stone-free rates, operative time and complications rate of flexible URS and PCNL in the subgroup of patients harbouring lower pole kidney stones between 1 and 2 cm in the higher diameter. Results A total 246 patients met the criteria for inclusion. There were 117 PCNLs (group 1) and 129 flexible URS (group 2). Ninety-six percent of cases were diagnosed by CT KUB scan. Mean stone burden was 175±160 and 50±62 mm2 for groups 1 and 2, respectively. General anaesthesia was induced in 100 % and 80% of groups 1 and 2, respectively. Pneumo-ultrasonic energy was used in 84% of cases in the PCNL group, and holmium laser in 95% of the cases in the flexible URS group. The mean operative time was 76.9±44 and 63±37 minutes for groups 1 and 2 respectively. There were 12 major complications (11%) in group 1 (mainly Grade II complications according to Clavidien classification) and no major complications in group 2. Mean hospital stay was 5.7 and 2.6 days for groups 1 and 2, respectively. Ninety-five percent of group 1 and 52% of group 2 required analgesia for a period longer than 24 hours. Intraoperative stone-free rate after a single treatment was 88.9% for group 1 and 79.1% for group 2. Overall, 6% of group 1 and 14.7% of group 2 required a second look procedure. At 3 months, stone-free rates were 90.6% and 92.2% for groups 1 and 2, respectively, as documented by follow-up CT KUB (22%) or combination of intra-venous pyelogram, regular KUB and/or kidney ultrasound (78%). In the subanalysis conducted comparing 82 vs 65 patients who underwent PCNL and flexible URS for lower pole stones between 1 and 2 cm, intreoperative stone-free rates were 88% vs 68% (p= 0.03), respectively; anyway, after an auxiliary procedure which was necessary in 6% of the cases in group 1 and 23% in group 2 (p=0.03), stone-free rates at 3 months were not statistically significant (91.5% vs 89.2%; p=0.6). Conversely, the patients undergoing PCNL maintained a higher risk of complications during the procedure, with 9 cases observed in this group versus 0 in the group of patients treated with URS (p=0.01) Conclusions These data highlight the value of flexible URS as a very effective and safe option for the treatment of kidney stones; thanks to the latest generation of flexible devices, this new technical approach seems to be a valid alternative in particular for the treatment of lower pole kidney stones less than 2 cm. In high-volume centres and in the hands of skilled surgeons, this technique can approach the stone-free rates achievable through PCNL in lower pole stones between 1 and 2 cm, with a very low risk of complications. Furthermore, the results confirm the high success rate and relatively low morbidity of modern PCNL for lower pole stones, with no difference detectable between the prone and supine position.
Resumo:
Background: The recent increasing incidence of intrahepatic cholangiocellular carcinoma (ICC) in cirrhosis increased the problem of noninvasive differential diagnosis between ICC and hepatocellular carcinoma (HCC) in cirrhosis. In literature there isn’t data about treatment and prognosis of ICC in cirrhosis. Aim: To investigate the role of the different imaging techniques in the diagnosis of ICC in cirrhosis; to analyze treatments and prognosis with particular attention to factors associated with survival. Methods: The data of 30 cirrhotic patients with ICC were retrospectively collected; patients were referred to Liver Units (S.Orsola-Malpighi and S.Matteo Hospitals) between 2005 and 2011. The results of contrast-enhanced ultrasound (CEUS), computed tomography (CT) and magnetic resonance (MR) were evaluated; the enhancement pattern at different imaging techniques were analysed, with particular attention to misdiagnosis of HCC. We evaluated the different treatments and survival of the study group and then we performed the survival analysis of different clinico-pathologic factors. Results: Twenty-five patients underwent CEUS, 27 CT and 10 MR. In 3 cases (12%) CEUS misdiagnosed ICC for HCC, in 7 cases (26%) CT misdiagnosed ICC and in 1 case (10%) MR misdiagnosed ICC. Patient were followed for a mean of 30 months (range:4-86), with a mean survival of 30 months. Twenty-four out of 30 patients were treated with curative approach, while the other 6 underwent TACE (n=4), radioembolization (n=1) or systemic treatment with Gemcitabine (n=1). The univariate analysis revealed that CA19-9 levels, surveillance program and nodule size were significantly related with survival. By multivariate analysis only nodule size £ 40mm was significant (p=0,004). Conclusion: Diagnosis of ICC in cirrhosis remains difficult because there isn’t a typical enhancement pattern and in some cases it cannot be distinguished from HCC by the different imaging techniques. The study of survival related factors shows that nodule size ≤ 40mm is correlated with improved survival.
Resumo:
La chirurgia con ultrasuoni focalizzati guidati da MRI (MR-g-FUS) è un trattamento di minima invasività, guidato dal più sofisticato strumento di imaging a disposizione, che utilizza a scopo diagnostico e terapeutico forme di energia non ionizzante. Le sue caratteristiche portano a pensare un suo possibile e promettente utilizzo in numerose aree della patologia umana, in particolare scheletrica. L'osteoma osteoide affligge frequentemente pazienti di giovane età, è una patologia benigna, con origine ed evoluzione non chiare, e trova nella termoablazione con radiofrequenza continua sotto guida CT (CT-g-RFA) il suo trattamento di elezione. Questo lavoro ha valutato l’efficacia, gli effetti e la sicurezza del trattamento dell’osteoma osteoide con MR-g-FUS. Sono stati presi in considerazione pazienti arruolati per MR-g-FUS e, come gruppo di controllo, pazienti sottoposti a CT-g-RFA, che hanno raggiunto un follow-up minimo di 18 mesi (rispettivamente 6 e 24 pazienti). Due pazienti erano stati esclusi dal trattamento MR-g-FUS per claustrofobia (2/8). Tutti i trattamenti sono stati portati a termine con successo tecnico e clinico. Non sono state registrate complicanze o eventi avversi correlati all’anestesia o alle procedure di trattamento, e tutti i pazienti sono stati dimessi regolarmente dopo 12-24 ore. La durata media dei trattamenti di MR-g-FUS è stata di 40±21 min. Da valori di score VAS pre-trattamento oscillanti tra 6 e 10 (su scala 0-10), i trattamenti hanno condotto tutti i pazienti a VAS 0 (senza integrazioni farmacologiche). Nessun paziente ha manifestato segni di persistenza di malattia o di recidiva al follow-up. Nonostante la neurolisi e la risoluzione dei sintomi, la perfusione del nidus è stata ritrovata ancora presente in oltre il 70% dei casi sottoposti a MR-g-FUS (4/6 pazienti). I risultati derivati da un'analisi estesa a pazienti più recentemente arruolati confermano questi dati. Il trattamento con MR-g-FUS sembra essere efficace e sicuro nel risolvere la sintomatologia dell'osteoma osteoide.
Resumo:
Perfusion CT imaging of the liver has potential to improve evaluation of tumour angiogenesis. Quantitative parameters can be obtained applying mathematical models to Time Attenuation Curve (TAC). However, there are still some difficulties for an accurate quantification of perfusion parameters due, for example, to algorithms employed, to mathematical model, to patient’s weight and cardiac output and to the acquisition system. In this thesis, new parameters and alternative methodologies about liver perfusion CT are presented in order to investigate the cause of variability of this technique. Firstly analysis were made to assess the variability related to the mathematical model used to compute arterial Blood Flow (BFa) values. Results were obtained implementing algorithms based on “ maximum slope method” and “Dual input one compartment model” . Statistical analysis on simulated data demonstrated that the two methods are not interchangeable. Anyway slope method is always applicable in clinical context. Then variability related to TAC processing in the application of slope method is analyzed. Results compared with manual selection allow to identify the best automatic algorithm to compute BFa. The consistency of a Standardized Perfusion Index (SPV) was evaluated and a simplified calibration procedure was proposed. At the end the quantitative value of perfusion map was analyzed. ROI approach and map approach provide related values of BFa and this means that pixel by pixel algorithm give reliable quantitative results. Also in pixel by pixel approach slope method give better results. In conclusion the development of new automatic algorithms for a consistent computation of BFa and the analysis and definition of simplified technique to compute SPV parameter, represent an improvement in the field of liver perfusion CT analysis.
Resumo:
Oggetto della tesi e' l'approfondimento su tecniche e metodiche di preservazione del polmone isolato per lo studio ecografico. E' discussa l'appropriatezza sull'uso degli ultrasuoni in corso di chirurgia mini invasiva polmonare, obiettivo di una ricerca sperimentale. Il razionale dello studio si fonda sull'indicazione all'exeresi chirurgica di noduli polmonari di diametro inferiore al centometro, ovvero di diametro superiore ma localizzati in aree centrali del polmone. Queste lesioni sono sempre piu' frequentente diagnosticate per mezzo di avanzate tecniche di imaging. L'atto chirurgico ha scopo terapeutico quando sia stata posta la diagnosi di neoplasia maligna, diagnostico-terapeutico quando non sia ancora ottenuta la tipizzazione istologica della lesione. La tecnica toracoscopica offre numerosi vantaggi rispetto alle tecniche chirurgiche tradizionali ma presenta il grave limite di non permettere la palpazione diretta del tessuto polmonare e la localizzazione della formazione tumorale quando essa non sia visibile macroscopicamente. Gli ultrasuoni sono stati utilizzati con successo per indirizzare la localizzazione del nodulo polmonare. Scopo dello studio sperimentale e' quello di confrontare tecniche diverse di preservazione del polmone isolato in un modello animale, comparando catatteristiche e prestazioni di sonde ecografiche differenti per tipologia. Del tutto recentemente, in ambito trapiantologico, sono state proposte tecniche di preservazione organica utili ai fini di uno studio anatomico sperimentale particolareggiato (EVLP) e moderna e' da considerarsi la concezione di mezzi tecnici specifici per la localizzazione di bersagli intrapolmonari. La tecnica clinica applicata allo studio del particolare ecografico, nel modello animale, ha reso comprensibile e meglio definito il ruolo delle sonde ecografiche nell'individuazione di forme tumorali suscettibili di exeresi definitiva.