3 resultados para torso segment masses
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
Human reactions to vibration have been extensively investigated in the past. Vibration, as well as whole-body vibration (WBV), has been commonly considered as an occupational hazard for its detrimental effects on human condition and comfort. Although long term exposure to vibrations may produce undesirable side-effects, a great part of the literature is dedicated to the positive effects of WBV when used as method for muscular stimulation and as an exercise intervention. Whole body vibration training (WBVT) aims to mechanically activate muscles by eliciting neuromuscular activity (muscle reflexes) via the use of vibrations delivered to the whole body. The most mentioned mechanism to explain the neuromuscular outcomes of vibration is the elicited neuromuscular activation. Local tendon vibrations induce activity of the muscle spindle Ia fibers, mediated by monosynaptic and polysynaptic pathways: a reflex muscle contraction known as the Tonic Vibration Reflex (TVR) arises in response to such vibratory stimulus. In WBVT mechanical vibrations, in a range from 10 to 80 Hz and peak to peak displacements from 1 to 10 mm, are usually transmitted to the patient body by the use of oscillating platforms. Vibrations are then transferred from the platform to a specific muscle group through the subject body. To customize WBV treatments, surface electromyography (SEMG) signals are often used to reveal the best stimulation frequency for each subject. Use of SEMG concise parameters, such as root mean square values of the recordings, is also a common practice; frequently a preliminary session can take place in order to discover the more appropriate stimulation frequency. Soft tissues act as wobbling masses vibrating in a damped manner in response to mechanical excitation; Muscle Tuning hypothesis suggest that neuromuscular system works to damp the soft tissue oscillation that occurs in response to vibrations; muscles alters their activity to dampen the vibrations, preventing any resonance phenomenon. Muscle response to vibration is however a complex phenomenon as it depends on different parameters, like muscle-tension, muscle or segment-stiffness, amplitude and frequency of the mechanical vibration. Additionally, while in the TVR study the applied vibratory stimulus and the muscle conditions are completely characterised (a known vibration source is applied directly to a stretched/shortened muscle or tendon), in WBV study only the stimulus applied to a distal part of the body is known. Moreover, mechanical response changes in relation to the posture. The transmissibility of vibratory stimulus along the body segment strongly depends on the position held by the subject. The aim of this work was the investigation on the effects that the use of vibrations, in particular the effects of whole body vibrations, may have on muscular activity. A new approach to discover the more appropriate stimulus frequency, by the use of accelerometers, was also explored. Different subjects, not affected by any known neurological or musculoskeletal disorders, were voluntarily involved in the study and gave their informed, written consent to participate. The device used to deliver vibration to the subjects was a vibrating platform. Vibrations impressed by the platform were exclusively vertical; platform displacement was sinusoidal with an intensity (peak-to-peak displacement) set to 1.2 mm and with a frequency ranging from 10 to 80 Hz. All the subjects familiarized with the device and the proper positioning. Two different posture were explored in this study: position 1 - hack squat; position 2 - subject standing on toes with heels raised. SEMG signals from the Rectus Femoris (RF), Vastus Lateralis (VL) and Vastus medialis (VM) were recorded. SEMG signals were amplified using a multi-channel, isolated biomedical signal amplifier The gain was set to 1000 V/V and a band pass filter (-3dB frequency 10 - 500 Hz) was applied; no notch filters were used to suppress line interference. Tiny and lightweight (less than 10 g) three-axial MEMS accelerometers (Freescale semiconductors) were used to measure accelerations of onto patient’s skin, at EMG electrodes level. Accelerations signals provided information related to individuals’ RF, Biceps Femoris (BF) and Gastrocnemius Lateralis (GL) muscle belly oscillation; they were pre-processed in order to exclude influence of gravity. As demonstrated by our results, vibrations generate peculiar, not negligible motion artifact on skin electrodes. Artifact amplitude is generally unpredictable; it appeared in all the quadriceps muscles analysed, but in different amounts. Artifact harmonics extend throughout the EMG spectrum, making classic high-pass filters ineffective; however, their contribution was easy to filter out from the raw EMG signal with a series of sharp notch filters centred at the vibration frequency and its superior harmonics (1.5 Hz wide). However, use of these simple filters prevents the revelation of EMG power potential variation in the mentioned filtered bands. Moreover our experience suggests that the possibility of reducing motion artefact, by using particular electrodes and by accurately preparing the subject’s skin, is not easily viable; even though some small improvements were obtained, it was not possible to substantially decrease the artifact. Anyway, getting rid of those artifacts lead to some true EMG signal loss. Nevertheless, our preliminary results suggest that the use of notch filters at vibration frequency and its harmonics is suitable for motion artifacts filtering. In RF SEMG recordings during vibratory stimulation only a little EMG power increment should be contained in the mentioned filtered bands due to synchronous electromyographic activity of the muscle. Moreover, it is better to remove the artifact that, in our experience, was found to be more than 40% of the total signal power. In summary, many variables have to be taken into account: in addition to amplitude, frequency and duration of vibration treatment, other fundamental variables were found to be subject anatomy, individual physiological condition and subject’s positioning on the platform. Studies on WBV treatments that include surface EMG analysis to asses muscular activity during vibratory stimulation should take into account the presence of motion artifacts. Appropriate filtering of artifacts, to reveal the actual effect on muscle contraction elicited by vibration stimulus, is mandatory. However as a result of our preliminary study, a simple multi-band notch filtering may help to reduce randomness of the results. Muscle tuning hypothesis seemed to be confirmed. Our results suggested that the effects of WBV are linked to the actual muscle motion (displacement). The greater was the muscle belly displacement the higher was found the muscle activity. The maximum muscle activity has been found in correspondence with the local mechanical resonance, suggesting a more effective stimulation at the specific system resonance frequency. Holding the hypothesis that muscle activation is proportional to muscle displacement, treatment optimization could be obtained by simply monitoring local acceleration (resonance). However, our study revealed some short term effects of vibratory stimulus; prolonged studies should be assembled in order to consider the long term effectiveness of these results. Since local stimulus depends on the kinematic chain involved, WBV muscle stimulation has to take into account the transmissibility of the stimulus along the body segment in order to ensure that vibratory stimulation effectively reaches the target muscle. Combination of local resonance and muscle response should also be further investigated to prevent hazards to individuals undergoing WBV treatments.
Resumo:
Objective: To investigate the prognostic significance of ST-segment elevation (STE) in aVR associated with ST-segment depression (STD) in other leads in patients with non-STE acute coronary syndrome (NSTE-ACS). Background: In NSTE-ACS patients, STD has been extensively associated with severe coronary lesions and poor outcomes. The prognostic role of STE in aVR is uncertain. Methods: We enrolled 888 consecutive patients with NSTE-ACS. They were divided into two groups according to the presence or not on admission ECG of aVR STE≥ 1mm and STD (defined as high risk ECG pattern). The primary and secondary endpoints were: in-hospital cardiovascular (CV) death and the rate of culprit left main disease (LMD). Results: Patients with high risk ECG pattern (n=121) disclosed a worse clinical profile compared to patients (n=575) without [median GRACE (Global-Registry-of-Acute-Coronary-Events) risk score =142 vs. 182, respectively]. A total of 75% of patients underwent coronary angiography. The rate of in-hospital CV death was 3.9%. On multivariable analysis patients who had the high risk ECG pattern showed an increased risk of CV death (OR=2.88, 95%CI 1.05-7.88) and culprit LMD (OR=4.67,95%CI 1.86-11.74) compared to patients who had not. The prognostic significance of the high risk ECG pattern was maintained even after adjustment for the GRACE risk score (OR = 2.28, 95%CI:1.06-4.93 and OR = 4.13, 95%CI:2.13-8.01, for primary and secondary endpoint, respectively). Conclusions: STE in aVR associated with STD in other leads predicts in-hospital CV death and culprit LMD. This pattern may add prognostic information in patients with NSTE-ACS on top of recommended scoring system.
Resumo:
Background: Chronic kidney disease (CKD) is one of the strongest risk factor for myocardial infarction (MI) and mortality. The aim of this study was to assess the association between renal dysfunction severity, short-term outcomes and the use of in-hospital evidence-based therapies among patients with non–ST-segment elevation myocardial infarction (NSTEMI). Methods: We examined data on 320 patients presenting with NSTEMI to Maggiore’s Emergency Department from 1st Jan 2010 to 31st December 2011. The study patients were classified into two groups according to their baseline glomerular filtration rate (GFR): renal dysfunction (RD) (GFR<60) and non-RD (GFR≥60 ml/min). Patients were then classified into four groups according to their CKD stage (GFR≥60, GFR 59-30, GFR 29-15, GFR <15). Results: Of the 320 patients, 155 (48,4%) had a GFR<60 ml/min at baseline. Compared with patients with a GFR≥60 ml/min, this group was, more likely to be female, to have hypertension, a previous myocardial infarction, stroke or TIA, had higher levels of uric acid and C-reactive protein. They were less likely to receive immediate (first 24 hours) evidence-based therapies. The GFR of RD patients treated appropriately increases on average by 5.5 ml/min/1.73 m2. The length of stay (mean, SD) increased with increasing CKD stage, respectively 5,3 (4,1), 7.0 (6.1), 7.8 (7.0), 9.2 (5.8) (global p <.0001). Females had on average a longer hospitalization than males, regardless of RD. In hospital mortality was higher in RD group (3,25%). Conclusions: The in-hospital mortality not was statically difference among the patients with a GFR value ≥60 ml/min, and patients with a GFR value <60 ml/min. The length of stay increased with increasing CKD stages. Despite patients with RD have more comorbidities then without RD less frequently receive guideline –recommended therapy. The GFR of RD patients treated appropriately improves during hospitalization, but not a level as we expected.