3 resultados para technical market indicators

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The research activity carried out during the PhD course in Electrical Engineering belongs to the branch of electric and electronic measurements. The main subject of the present thesis is a distributed measurement system to be installed in Medium Voltage power networks, as well as the method developed to analyze data acquired by the measurement system itself and to monitor power quality. In chapter 2 the increasing interest towards power quality in electrical systems is illustrated, by reporting the international research activity inherent to the problem and the relevant standards and guidelines emitted. The aspect of the quality of voltage provided by utilities and influenced by customers in the various points of a network came out only in recent years, in particular as a consequence of the energy market liberalization. Usually, the concept of quality of the delivered energy has been associated mostly to its continuity. Hence the reliability was the main characteristic to be ensured for power systems. Nowadays, the number and duration of interruptions are the “quality indicators” commonly perceived by most customers; for this reason, a short section is dedicated also to network reliability and its regulation. In this contest it should be noted that although the measurement system developed during the research activity belongs to the field of power quality evaluation systems, the information registered in real time by its remote stations can be used to improve the system reliability too. Given the vast scenario of power quality degrading phenomena that usually can occur in distribution networks, the study has been focused on electromagnetic transients affecting line voltages. The outcome of such a study has been the design and realization of a distributed measurement system which continuously monitor the phase signals in different points of a network, detect the occurrence of transients superposed to the fundamental steady state component and register the time of occurrence of such events. The data set is finally used to locate the source of the transient disturbance propagating along the network lines. Most of the oscillatory transients affecting line voltages are due to faults occurring in any point of the distribution system and have to be seen before protection equipment intervention. An important conclusion is that the method can improve the monitored network reliability, since the knowledge of the location of a fault allows the energy manager to reduce as much as possible both the area of the network to be disconnected for protection purposes and the time spent by technical staff to recover the abnormal condition and/or the damage. The part of the thesis presenting the results of such a study and activity is structured as follows: chapter 3 deals with the propagation of electromagnetic transients in power systems by defining characteristics and causes of the phenomena and briefly reporting the theory and approaches used to study transients propagation. Then the state of the art concerning methods to detect and locate faults in distribution networks is presented. Finally the attention is paid on the particular technique adopted for the same purpose during the thesis, and the methods developed on the basis of such approach. Chapter 4 reports the configuration of the distribution networks on which the fault location method has been applied by means of simulations as well as the results obtained case by case. In this way the performance featured by the location procedure firstly in ideal then in realistic operating conditions are tested. In chapter 5 the measurement system designed to implement the transients detection and fault location method is presented. The hardware belonging to the measurement chain of every acquisition channel in remote stations is described. Then, the global measurement system is characterized by considering the non ideal aspects of each device that can concur to the final combined uncertainty on the estimated position of the fault in the network under test. Finally, such parameter is computed according to the Guide to the Expression of Uncertainty in Measurements, by means of a numeric procedure. In the last chapter a device is described that has been designed and realized during the PhD activity aiming at substituting the commercial capacitive voltage divider belonging to the conditioning block of the measurement chain. Such a study has been carried out aiming at providing an alternative to the used transducer that could feature equivalent performance and lower cost. In this way, the economical impact of the investment associated to the whole measurement system would be significantly reduced, making the method application much more feasible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

At global level, the population is increasingly concentrating in the cities. In Europe, around 75% of the population lives in urban areas and, according to the European Environmental Agency (2010), urban population is foreseen to increase up to 80 % by 2020. At the same time, the quality of life in the cities is declining and urban pollution keeps increasing in terms of carbon dioxide (CO2) emissions, waste, noise, and lack of greenery. Many of European cities struggle to cope with social, economic and environmental problems resulting from pressures such as overcrowding or decline, social inequity, health problems related to food security and pollution. Nowadays local authorities try to solve these problems related to the environmental sustainability through various urban logistics measures, which directly and indirectly affect the urban food supply system, thus an integrated approach including freight transport and food provisioning policies issues is needed. This research centres on the urban food transport system and its impact on the city environmental sustainability. The main question that drives the research analysis is "How the urban food distribution system affects the ecological sustainability in modern cities?" The research analyses the city logistics project for food transport implemented in Parma, Italy, by the wholesale produce market. The case study investigates the renewed role of the wholesale market in the urban food supply chain as commercial and logistic operator, referring to the concept of food hub. Then, a preliminary analysis on the urban food transport for the city of Bologna is presented. The research aims at suggesting a methodological framework to estimate the urban food demand, the urban food supply and to assess the urban food transport performance, in order to identify external costs indicators that help policymakers in evaluating the environmental sustainability of different logistics measures

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This dissertation comprises three essays on the Turkish labor market. The first essay characterizes the distinctive characteristics of the Turkish labor market with the aim of understanding the factors lying behind its long-standing poor performance relative to its European counterparts. The analysis is based on a cross-country comparison among selected European Union countries. Among all the indicators of labor market flexibility, non-wage cost rigidities are regarded as one of the most important factors in slowing down employment creation in Turkey. The second essay focuses on an employment subsidy policy which introduces a reduction in non-wage costs through social security premium incentives granted to women and young men. Exploiting a difference-in-difference-in differences strategy, I evaluate the effectiveness of this policy in creating employment for the target group. The results, net of the recent crisis effect, suggest that the policy accounts for a 1.4% to 1.6% increase in the probability of being hired for women aged 30 to 34 above men of the same age group in the periods shortly after the announcement of the policy. In the third essay of the dissertation, I analyze the labor supply response of married women to their husbands' job losses (AWE). I empirically test the hypothesis of added worker effect for the global economic crisis of 2008 by relying on the Turkey context. Identification is achieved by exploiting the exogenous variation in the output of male-dominated sectors hard-hit by the crisis and the gender-segmentation that characterizes the Turkish labor market. Findings based on the instrumental variable approach suggest that the added worker effect explains up to 64% of the observed increase in female labor force participation in Turkey. The size of the effect depends on how long it takes for wives to adjust their labor supply to their husbands' job losses.