6 resultados para sensor and actuators

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have realized a Data Acquisition chain for the use and characterization of APSEL4D, a 32 x 128 Monolithic Active Pixel Sensor, developed as a prototype for frontier experiments in high energy particle physics. In particular a transition board was realized for the conversion between the chip and the FPGA voltage levels and for the signal quality enhancing. A Xilinx Spartan-3 FPGA was used for real time data processing, for the chip control and the communication with a Personal Computer through a 2.0 USB port. For this purpose a firmware code, developed in VHDL language, was written. Finally a Graphical User Interface for the online system monitoring, hit display and chip control, based on windows and widgets, was realized developing a C++ code and using Qt and Qwt dedicated libraries. APSEL4D and the full acquisition chain were characterized for the first time with the electron beam of the transmission electron microscope and with 55Fe and 90Sr radioactive sources. In addition, a beam test was performed at the T9 station of the CERN PS, where hadrons of momentum of 12 GeV/c are available. The very high time resolution of APSEL4D (up to 2.5 Mfps, but used at 6 kfps) was fundamental in realizing a single electron Young experiment using nanometric double slits obtained by a FIB technique. On high statistical samples, it was possible to observe the interference and diffractions of single isolated electrons traveling inside a transmission electron microscope. For the first time, the information on the distribution of the arrival time of the single electrons has been extracted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An Adaptive Optic (AO) system is a fundamental requirement of 8m-class telescopes. We know that in order to obtain the maximum possible resolution allowed by these telescopes we need to correct the atmospheric turbulence. Thanks to adaptive optic systems we are able to use all the effective potential of these instruments, drawing all the information from the universe sources as best as possible. In an AO system there are two main components: the wavefront sensor (WFS) that is able to measure the aberrations on the incoming wavefront in the telescope, and the deformable mirror (DM) that is able to assume a shape opposite to the one measured by the sensor. The two subsystem are connected by the reconstructor (REC). In order to do this, the REC requires a “common language" between these two main AO components. It means that it needs a mapping between the sensor-space and the mirror-space, called an interaction matrix (IM). Therefore, in order to operate correctly, an AO system has a main requirement: the measure of an IM in order to obtain a calibration of the whole AO system. The IM measurement is a 'mile stone' for an AO system and must be done regardless of the telescope size or class. Usually, this calibration step is done adding to the telescope system an auxiliary artificial source of light (i.e a fiber) that illuminates both the deformable mirror and the sensor, permitting the calibration of the AO system. For large telescope (more than 8m, like Extremely Large Telescopes, ELTs) the fiber based IM measurement requires challenging optical setups that in some cases are also impractical to build. In these cases, new techniques to measure the IM are needed. In this PhD work we want to check the possibility of a different method of calibration that can be applied directly on sky, at the telescope, without any auxiliary source. Such a technique can be used to calibrate AO system on a telescope of any size. We want to test the new calibration technique, called “sinusoidal modulation technique”, on the Large Binocular Telescope (LBT) AO system, which is already a complete AO system with the two main components: a secondary deformable mirror with by 672 actuators, and a pyramid wavefront sensor. My first phase of PhD work was helping to implement the WFS board (containing the pyramid sensor and all the auxiliary optical components) working both optical alignments and tests of some optical components. Thanks to the “solar tower” facility of the Astrophysical Observatory of Arcetri (Firenze), we have been able to reproduce an environment very similar to the telescope one, testing the main LBT AO components: the pyramid sensor and the secondary deformable mirror. Thanks to this the second phase of my PhD thesis: the measure of IM applying the sinusoidal modulation technique. At first we have measured the IM using a fiber auxiliary source to calibrate the system, without any kind of disturbance injected. After that, we have tried to use this calibration technique in order to measure the IM directly “on sky”, so adding an atmospheric disturbance to the AO system. The results obtained in this PhD work measuring the IM directly in the Arcetri solar tower system are crucial for the future development: the possibility of the acquisition of IM directly on sky means that we are able to calibrate an AO system also for extremely large telescope class where classic IM measurements technique are problematic and, sometimes, impossible. Finally we have not to forget the reason why we need this: the main aim is to observe the universe. Thanks to these new big class of telescopes and only using their full capabilities, we will be able to increase our knowledge of the universe objects observed, because we will be able to resolve more detailed characteristics, discovering, analyzing and understanding the behavior of the universe components.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Increasingly stringent exhaust emission limits and higher fuel economy are the main drivers of the engine development process. As a consequence, the complexity of the propulsion units and its subsystems increase, due to the extensive use of sensors and actuators needed to obtain a precise control over the combustion phase. Since engine calibration process consumes most of the development time, new tools and methodologies are needed to shorten the development time and increase the performance attainable. Real time combustion analysis, based on the in-cylinder pressure signal, can significantly improve the calibration of the engine control strategies and the development of new algorithms, giving instantaneous feedback on the engine behavior. A complete combustion analysis and diagnosis system has been developed, capable of evaluating the most important indicators about the combustion process, such as indicated mean effective pressure, heat release, mass fraction burned and knock indexes. Such a tool is built on top of a flexible, modular and affordable hardware platform, capable of satisfying the requirements needed for accuracy and precision, but also enabling the use directly on-board the vehicle, due to its small form factor.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

L’attività di dottorato qui descritta ha riguardato inizialmente lo sviluppo di biosensori elettrochimici semplificati per la rilevazione di DNA e successivamente lo studio di dispositivi organici ad effetto di campo per la stimolazione e il rilevamento dell’attività bioelettrica di cellule neuronali. Il lavoro di ricerca riguardante il prima parte è stato focalizzato sulla fabbricazione e sulla caratterizzazione di un biosensore a due elettrodi per la rilevazione di DNA solubile , facilmente producibile a livello industriale. Tale sensore infatti, è in grado di leggere livelli diversi di correnti faradiche sulle superfici in oro degli elettrodi, a discrezione di un eventuale ibridizzazione del DNA da analizzare su di esse. I risultati ottenuti riguardo a questo biosensore sono :la paragonabilità dello stesso con i sensori standard a tre elettrodi basati sulla medesima metodica, la possibilità di effettuare due misure in parallelo di uno stesso campione o di 2 diversi campioni su di uno stesso di dispositivo e la buona applicabilità della chimica superficiale a base di tale biosensore a superfici create con tecnologie industriali. Successivamente a tali studi, mi sono focalizzato sull’utilizzo di dispositivi organici ad effetto campo (in particolare OTFT) per lo sviluppo di un biosensore capace di stimolare e registrare l’attività bioelettrica di cellule neuronali. Inizialmente sono state identificate le caratteristiche del materiale organico utilizzato e successivamente del dispositivo fabbricato pre e post esposizione all’ambiente fisiologico. Poi, sono stati effettuati esperimenti per osservare la capacità di stimolare e di leggere i segnali elettrogenici da parte dell’OTFT. I risultati ottenuti da tali studi sono che: il materiale organico ed il dispositivo mantengo le loro caratteristiche morfologiche e funzionali dopo l’esposizione per giorni all’ambiente fisiologico. Inoltre l’OFET in grado di stimolare il cambiamento delle tensioni di membrana cellulari e contemporaneamente di registrare tali variazioni e le eventuali risposte cellulari provocate da esse.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A control-oriented model of a Dual Clutch Transmission was developed for real-time Hardware In the Loop (HIL) applications, to support model-based development of the DCT controller. The model is an innovative attempt to reproduce the fast dynamics of the actuation system while maintaining a step size large enough for real-time applications. The model comprehends a detailed physical description of hydraulic circuit, clutches, synchronizers and gears, and simplified vehicle and internal combustion engine sub-models. As the oil circulating in the system has a large bulk modulus, the pressure dynamics are very fast, possibly causing instability in a real-time simulation; the same challenge involves the servo valves dynamics, due to the very small masses of the moving elements. Therefore, the hydraulic circuit model has been modified and simplified without losing physical validity, in order to adapt it to the real-time simulation requirements. The results of offline simulations have been compared to on-board measurements to verify the validity of the developed model, that was then implemented in a HIL system and connected to the TCU (Transmission Control Unit). Several tests have been performed: electrical failure tests on sensors and actuators, hydraulic and mechanical failure tests on hydraulic valves, clutches and synchronizers, and application tests comprehending all the main features of the control performed by the TCU. Being based on physical laws, in every condition the model simulates a plausible reaction of the system. The first intensive use of the HIL application led to the validation of the new safety strategies implemented inside the TCU software. A test automation procedure has been developed to permit the execution of a pattern of tests without the interaction of the user; fully repeatable tests can be performed for non-regression verification, allowing the testing of new software releases in fully automatic mode.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La tesi è suddivisa in due parti. La prima è dedicata alla determinazione della Deflessione della Verticale (DdV) in Medicina (BO). Vengono presentati tre metodi per la determinazione delle componenti della DdV. Il primo utilizza la livellazione geometrica ed il sistema GNSS, il secondo, eseguito dal dott. Serantoni, utilizza il sistema QDaedalus, messo a punto all' ETH di Zurigo ed il terzo approccio utilizza il programma ConvER, messo a disposizione dalla regione Emilia-Romagna. Nella seconda parte viene presentato un metodo per la determinazione del Coefficiente di Rifrazione Atmosferico (CRA). La procedura di calcolo è di tipo iterativo ed utilizza, oltre agli angoli zenitali, anche le distanze misurate. Il metodo è stato testato in due aree di studio. La prima nella città di Limassol (Cipro) in ambiente urbano nell' autunno 2013. La seconda in Venezia nella laguna durante l'estate 2014.