5 resultados para point-of-care testing (POCT)

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays microfluidic is becoming an important technology in many chemical and biological processes and analysis applications. The potential to replace large-scale conventional laboratory instrumentation with miniaturized and self-contained systems, (called lab-on-a-chip (LOC) or point-of-care-testing (POCT)), offers a variety of advantages such as low reagent consumption, faster analysis speeds, and the capability of operating in a massively parallel scale in order to achieve high-throughput. Micro-electro-mechanical-systems (MEMS) technologies enable both the fabrication of miniaturized system and the possibility of developing compact and portable systems. The work described in this dissertation is towards the development of micromachined separation devices for both high-speed gas chromatography (HSGC) and gravitational field-flow fractionation (GrFFF) using MEMS technologies. Concerning the HSGC, a complete platform of three MEMS-based GC core components (injector, separation column and detector) is designed, fabricated and characterized. The microinjector consists of a set of pneumatically driven microvalves, based on a polymeric actuating membrane. Experimental results demonstrate that the microinjector is able to guarantee low dead volumes, fast actuation time, a wide operating temperature range and high chemical inertness. The microcolumn consists of an all-silicon microcolumn having a nearly circular cross-section channel. The extensive characterization has produced separation performances very close to the theoretical ideal expectations. A thermal conductivity detector (TCD) is chosen as most proper detector to be miniaturized since the volume reduction of the detector chamber results in increased mass and reduced dead volumes. The microTDC shows a good sensitivity and a very wide dynamic range. Finally a feasibility study for miniaturizing a channel suited for GrFFF is performed. The proposed GrFFF microchannel is at early stage of development, but represents a first step for the realization of a highly portable and potentially low-cost POCT device for biomedical applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La prima parte del nostro studio riguarda la tecnica LAMP (Loop-mediated isothermal amplification), una tecnica di amplificazione isotermica recentemente inventata (Notomi et al., 2000). Essa presenta notevoli vantaggi rispetto alle tradizionali PCR: non necessita di strumentazioni sofisticate come i termociclatori, può essere eseguita da personale non specializzato, è una tecnica altamente sensibile e specifica ed è molto tollerante agli inibitori. Tutte queste caratteristiche fanno sì che essa possa essere utilizzata al di fuori dei laboratori diagnostici, come POCT (Point of care testing), con il vantaggio di non dover gestire la spedizione del campione e di avere in tempi molto brevi risultati paragonabili a quelli ottenuti con la tradizionale PCR. Sono state prese in considerazione malattie infettive sostenute da batteri che richiedono tempi molto lunghi per la coltivazione o che non sono addirittura coltivabili. Sono stati disegnati dei saggi per la diagnosi di patologie virali che necessitano di diagnosi tempestiva. Altri test messi a punto riguardano malattie genetiche del cane e due batteri d’interesse agro-alimentare. Tutte le prove sono state condotte con tecnica real-time per diminuire il rischio di cross-contaminazione pur riuscendo a comprendere in maniera approfondita l’andamento delle reazioni. Infine è stato messo a punto un metodo di visualizzazione colorimetrico utilizzabile con tutti i saggi messi a punto, che svincola completamente la reazione LAMP dall’esecuzione in un laboratorio specializzato. Il secondo capitolo riguarda lo studio dal punto di vista molecolare di un soggetto che presenza totale assenza di attività mieloperossidasica all’analisi di citochimica automatica (ADVIA® 2120 Hematology System). Lo studio è stato condotto attraverso amplificazione e confronto dei prodotti di PCR ottenuti sul soggetto patologico e su due soggetti con fenotipo wild-type. Si è poi provveduto al sequenziamento dei prodotti di PCR su sequenziatore automatico al fine di ricercare la mutazione responsabile della carenza di MPO nel soggetto indicato.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The subject of this Ph.D. research thesis is the development and application of multiplexed analytical methods based on bioluminescent whole-cell biosensors. One of the main goals of analytical chemistry is multianalyte testing in which two or more analytes are measured simultaneously in a single assay. The advantages of multianalyte testing are work simplification, high throughput, and reduction in the overall cost per test. The availability of multiplexed portable analytical systems is of particular interest for on-field analysis of clinical, environmental or food samples as well as for the drug discovery process. To allow highly sensitive and selective analysis, these devices should combine biospecific molecular recognition with ultrasensitive detection systems. To address the current need for rapid, highly sensitive and inexpensive devices for obtaining more data from each sample,genetically engineered whole-cell biosensors as biospecific recognition element were combined with ultrasensitive bioluminescence detection techniques. Genetically engineered cell-based sensing systems were obtained by introducing into bacterial, yeast or mammalian cells a vector expressing a reporter protein whose expression is controlled by regulatory proteins and promoter sequences. The regulatory protein is able to recognize the presence of the analyte (e.g., compounds with hormone-like activity, heavy metals…) and to consequently activate the expression of the reporter protein that can be readily measured and directly related to the analyte bioavailable concentration in the sample. Bioluminescence represents the ideal detection principle for miniaturized analytical devices and multiplexed assays thanks to high detectability in small sample volumes allowing an accurate signal localization and quantification. In the first chapter of this dissertation is discussed the obtainment of improved bioluminescent proteins emitting at different wavelenghts, in term of increased thermostability, enhanced emission decay kinetic and spectral resolution. The second chapter is mainly focused on the use of these proteins in the development of whole-cell based assay with improved analytical performance. In particular since the main drawback of whole-cell biosensors is the high variability of their analyte specific response mainly caused by variations in cell viability due to aspecific effects of the sample’s matrix, an additional bioluminescent reporter has been introduced to correct the analytical response thus increasing the robustness of the bioassays. The feasibility of using a combination of two or more bioluminescent proteins for obtaining biosensors with internal signal correction or for the simultaneous detection of multiple analytes has been demonstrated by developing a dual reporter yeast based biosensor for androgenic activity measurement and a triple reporter mammalian cell-based biosensor for the simultaneous monitoring of two CYP450 enzymes activation, involved in cholesterol degradation, with the use of two spectrally resolved intracellular luciferases and a secreted luciferase as a control for cells viability. In the third chapter is presented the development of a portable multianalyte detection system. In order to develop a portable system that can be used also outside the laboratory environment even by non skilled personnel, cells have been immobilized into a new biocompatible and transparent polymeric matrix within a modified clear bottom black 384 -well microtiter plate to obtain a bioluminescent cell array. The cell array was placed in contact with a portable charge-coupled device (CCD) light sensor able to localize and quantify the luminescent signal produced by different bioluminescent whole-cell biosensors. This multiplexed biosensing platform containing whole-cell biosensors was successfully used to measure the overall toxicity of a given sample as well as to obtain dose response curves for heavy metals and to detect hormonal activity in clinical samples (PCT/IB2010/050625: “Portable device based on immobilized cells for the detection of analytes.” Michelini E, Roda A, Dolci LS, Mezzanotte L, Cevenini L , 2010). At the end of the dissertation some future development steps are also discussed in order to develop a point of care (POCT) device that combine portability, minimum sample pre-treatment and highly sensitive multiplexed assays in a short assay time. In this POCT perspective, field-flow fractionation (FFF) techniques, in particular gravitational variant (GrFFF) that exploit the earth gravitational field to structure the separation, have been investigated for cells fractionation, characterization and isolation. Thanks to the simplicity of its equipment, amenable to miniaturization, the GrFFF techniques appears to be particularly suited for its implementation in POCT devices and may be used as pre-analytical integrated module to be applied directly to drive target analytes of raw samples to the modules where biospecifc recognition reactions based on ultrasensitive bioluminescence detection occurs, providing an increase in overall analytical output.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nucleic acid biosensors represent a powerful tool for clinical and environmental pathogens detection. For applications such as point-of-care biosensing, it is fundamental to develop sensors that should be automatic, inexpensive, portable and require a professional skill of the user that should be as low as possible. With the goal of determining the presence of pathogens when present in very small amount, such as for the screening of pathogens in drinking water, an amplification step must be implemented. Often this type of determinations should be performed with simple, automatic and inexpensive hardware: the use of a chemical (or nanotechnological) isothermal solution would be desirable. My Ph.D. project focused on the study and on the testing of four isothermal reactions which can be used to amplify the nucleic acid analyte before the binding event on the surface sensor or to amplify the signal after that the hybridization event with the probe. Recombinase polymerase amplification (RPA) and ligation-mediated rolling circle amplification (L-RCA) were investigated as methods for DNA and RNA amplification. Hybridization chain reaction (HCR) and Terminal deoxynucleotidil transferase-mediated amplification were investigated as strategies to achieve the enhancement of the signal after the surface hybridization event between target and probe. In conclusion, it can be said that only a small subset of the biochemical strategies that are proved to work in solution towards the amplification of nucleic acids does truly work in the context of amplifying the signal of a detection system for pathogens. Amongst those tested during my Ph.D. activity, recombinase polymerase amplification seems the best candidate for a useful implementation in diagnostic or environmental applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La presente tesi di dottorato affronta alcune delle più comuni malattie immunomediate del cane e del gatto. Il manoscritto è incentrato sugli aspetti diagnostici e terapeutici in corso di: anemia emolitica immunomediata (Immune-mediated hemolytic anemia, IMHA), trombocitopenia immunomediata (Immune-mediated thrombocytopenia, ITP) e poliartrite immunomediata (Immune-mediated polyarthritis, IMP). Il capitolo 1 costituisce un’introduzione all’argomento delle malattie immunologiche; vengono sottolineati alcuni aspetti patogenetici delle singole malattie immunomediate e riassunte le difficoltà diagnostiche e terapeutiche. Il capitolo 2 riporta uno studio riguardante una popolazione di gatti con diagnosi, o sospetto diagnostico, di IMHA che evidenziava una discrepanza tra i test diagnostici per il virus della leucemia felina (Feline Leukemia Virus, FeLV). La positività FeLV al test point of care, non confermata dalla PCR del DNA provirale, lascia spazio a diverse interpretazioni. Il capitolo 3 mostra i dati relativi al confronto tra tre diversi protocolli immunosoppressivi (glucocorticoidi, glucocorticoidi+ciclosporina, glucocorticoidi+micofenolato mofetile) in una popolazione di cani con IMHA non associativa. Il confronto verteva, principalmente, sulla risposta ematologica dei pazienti, che non si è dimostrata differente tra i tre gruppi terapeutici. Il capitolo 4 riporta una revisione della letteratura riguardante l’ITP del cane e del gatto. Si tratta di una malattia eterogenea in cui le manifestazioni cliniche appaiono variabili: alcuni pazienti sono asintomatici, altri presentano dei sanguinamenti spontanei. La mancanza di criteri diagnostici standardizzati, porta il clinico a considerare l’ITP una diagnosi “ad esclusione”. Le strategie terapeutiche non si basano purtroppo su linee guida condivise, pertanto il target della terapia rimane, ad oggi, sconosciuto. Nel capitolo 5 viene posta l’attenzione su alcuni interrogativi diagnostici e terapeutici che riguardano l’IMP del cane e del gatto. La sintomatologia clinica, caratterizzata da zoppia, febbre e riluttanza al movimento, talvolta può essere subdola. Anche in questa malattia, non vi sono evidenze scientifiche circa il regime immunosoppressivo più corretto ed indicato.