8 resultados para occupy movement

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cardiovascular regulation undergoes wide changes in the different states of sleepwake cycle. In particular, the relationship between spontaneous fluctuations in heart period and arterial pressure clearly shows differences between the two sleep states. In non rapid-eye-movement sleep, heart rhythm is under prevalent baroreflex control, whereas in rapid-eye-movement sleep central autonomic commands prevail (Zoccoli et al., 2001). Moreover, during rapid-eye-movement sleep the cardiovascular variables show wide fluctuations around their mean value. In particular, during rapid-eyemovement sleep, the arterial pressure shows phasic hypertensive events which are superimposed upon the tonic level of arterial pressure. These phasic increases in arterial pressure are accompanied by an increase in heart rate (Sei & Morita, 1996; Silvani et al., 2005). Thus, rapid-eye-movement sleep may represent an “autonomic stress test” for the cardiovascular system, able to unmask pathological patterns of cardiovascular regulation (Verrier et al. 2005), but this hypothesis has never been tested experimentally. The aim of this study was to investigate whether rapid-eye-movement sleep may reveal derangements in central autonomic cardiovascular control in an experimental model of essential hypertension. The study was performed in Spontaneously Hypertensive Rats, which represent the most widely used model of essential hypertension, and allow full control of genetic and environmental confounding factors. In particular, we analyzed the cardiovascular, electroencephalogram, and electromyogram changes associated with phasic hypertensive events during rapid-eyemovement sleep in Spontaneously Hypertensive Rats and in their genetic Wistar Kyoto control strain. Moreover, we studied also a group of Spontaneously Hypertensive Rats made phenotypically normotensive by means of a chronic treatment with an angiotensin converting enzyme inhibitor, the Enalapril maleate, from the age of four weeks to the end of the experiment. All rats were implanted with electrodes for electroencephalographic and electromyographic recordings and with an arterial catheter for arterial pressure measurement. After six days for postoperative recovery, the rats were studied for five days, at an age of ten weeks.The study indicated that the peak of mean arterial pressure increase during the phasic hypertensive events in rapid-eye-movement sleep did not differ significantly between Spontaneously Hypertensive Rats and Wistar Kyoto rats, while on the other hand Spontaneously Hypertensive Rats showed a reduced increase in the frequency of theta rhythm and a reduced tachicardia with respect to Wistar Kyoto rats. The same pattern of changes in mean arterial pressure, heart period, and theta frequency was observed between Spontaneously Hypertensive Rats and Spontaneously Hypertensive Rats treated with Enalapril maleate. Spontaneously Hypertensive Rats do not differ from Wistar Kyoto rats only in terms of arterial hypertension, but also due to multiple unknown genetic differences. Spontaneously Hypertensive Rats were developed by selective breeding of Wistar Kyoto rats based only on the level of arterial pressure. However, in this process, multiple genes possibly unrelated to hypertension may have been selected together with the genetic determinants of hypertension (Carley et al., 2000). This study indicated that Spontaneously Hypertensive Rats differ from Wistar Kyoto rats, but not from Spontaneously Hypertensive Rats treated with Enalapril maleate, in terms of arterial pH and theta frequency. This feature may be due to genetic determinants unrelated to hypertension. In sharp contrast, the persistence of differences in the peak of heart period decrease and the peak of theta frequency increase during phasic hypertensive events between Spontaneously Hypertensive Rats and Spontaneously Hypertensive Rats treated with Enalapril maleate demonstrates that the observed reduction in central autonomic control of the cardiovascular system in Spontaneously Hypertensive Rats is not an irreversible consequence of inherited genetic determinants. Rather, the comparison between Spontaneously Hypertensive Rats and Spontaneously Hypertensive Rats treated with Enalapril maleate indicates that the observed differences in central autonomic control are the result of the hypertension per se. This work supports the view that the study of cardiovascular regulation in sleep provides fundamental insight on the pathophysiology of hypertension, and may thus contribute to the understanding of this disease, which is a major health problem in European countries (Wolf-Maier et al., 2003) with its burden of cardiac, vascular, and renal complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human movement analysis (HMA) aims to measure the abilities of a subject to stand or to walk. In the field of HMA, tests are daily performed in research laboratories, hospitals and clinics, aiming to diagnose a disease, distinguish between disease entities, monitor the progress of a treatment and predict the outcome of an intervention [Brand and Crowninshield, 1981; Brand, 1987; Baker, 2006]. To achieve these purposes, clinicians and researchers use measurement devices, like force platforms, stereophotogrammetric systems, accelerometers, baropodometric insoles, etc. This thesis focus on the force platform (FP) and in particular on the quality assessment of the FP data. The principal objective of our work was the design and the experimental validation of a portable system for the in situ calibration of FPs. The thesis is structured as follows: Chapter 1. Description of the physical principles used for the functioning of a FP: how these principles are used to create force transducers, such as strain gauges and piezoelectrics transducers. Then, description of the two category of FPs, three- and six-component, the signals acquisition (hardware structure), and the signals calibration. Finally, a brief description of the use of FPs in HMA, for balance or gait analysis. Chapter 2. Description of the inverse dynamics, the most common method used in the field of HMA. This method uses the signals measured by a FP to estimate kinetic quantities, such as joint forces and moments. The measures of these variables can not be taken directly, unless very invasive techniques; consequently these variables can only be estimated using indirect techniques, as the inverse dynamics. Finally, a brief description of the sources of error, present in the gait analysis. Chapter 3. State of the art in the FP calibration. The selected literature is divided in sections, each section describes: systems for the periodic control of the FP accuracy; systems for the error reduction in the FP signals; systems and procedures for the construction of a FP. In particular is detailed described a calibration system designed by our group, based on the theoretical method proposed by ?. This system was the “starting point” for the new system presented in this thesis. Chapter 4. Description of the new system, divided in its parts: 1) the algorithm; 2) the device; and 3) the calibration procedure, for the correct performing of the calibration process. The algorithm characteristics were optimized by a simulation approach, the results are here presented. In addiction, the different versions of the device are described. Chapter 5. Experimental validation of the new system, achieved by testing it on 4 commercial FPs. The effectiveness of the calibration was verified by measuring, before and after calibration, the accuracy of the FPs in measuring the center of pressure of an applied force. The new system can estimate local and global calibration matrices; by local and global calibration matrices, the non–linearity of the FPs was quantified and locally compensated. Further, a non–linear calibration is proposed. This calibration compensates the non– linear effect in the FP functioning, due to the bending of its upper plate. The experimental results are presented. Chapter 6. Influence of the FP calibration on the estimation of kinetic quantities, with the inverse dynamics approach. Chapter 7. The conclusions of this thesis are presented: need of a calibration of FPs and consequential enhancement in the kinetic data quality. Appendix: Calibration of the LC used in the presented system. Different calibration set–up of a 3D force transducer are presented, and is proposed the optimal set–up, with particular attention to the compensation of non–linearities. The optimal set–up is verified by experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La tesi si è consolidata nell’analisi dell’impatto dei social networks nella costruzione dello spazio pubblico, nella sfera di osservazione che è la rete e il web2.0. Osservando che il paradigma della società civile si sia modificato. Ridefinendo immagini e immaginari e forme di autorappresentazione sui new media (Castells, 2010). Nel presupposto che lo spazio pubblico “non è mai una realtà precostituita” (Innerarity, 2008) ma si muove all’interno di reti che generano e garantiscono socievolezza. Nell’obiettivo di capire cosa è spazio pubblico. Civic engagement che si rafforza in spazi simbolici (Sassen, 2008), nodi d’incontro significativi. Ivi cittadini-consumatori avanzano corresponsabilmente le proprie istanze per la debacle nei governi.. Cultura partecipativa che prende mossa da un nuovo senso civico mediato che si esprime nelle “virtù” del consumo critico. Portando la politica sul mercato. Cultura civica autoattualizzata alla ricerca di soluzioni alle crisi degli ultimi anni. Potere di una comunicazione che riduce il mondo ad un “villaggio globale” e mettono in relazione i pubblici connessi in spazi e tempi differenti, dando origine ad azioni collettive come nel caso degli Indignados, di Occupy Wall Street o di Rai per una notte. Emerge un (ri)pensare la citizenship secondo due paradigmi (Bennett,2008): l’uno orientato al governo attraverso i partiti, modello “Dutiful Citizenship”; l’altro, modello “Self Actualizing Citizenship” per cui i pubblici attivi seguono news ed eventi, percepiscono un minor obbligo nel governo, il voto è meno significativo per (s)fiducia nei media e nei politici. Mercato e società civile si muovono per il bene comune e una nuova “felicità”. La partecipazione si costituisce in consumerismo politico all’interno di reti in cui si sviluppano azioni individuali attraverso il social networking e scelte di consumo responsabile. Partendo dall’etnografia digitale, si è definito il modello “4 C”: Conoscenza > Coadesione > Co-partecipazione > Corresposabilità (azioni collettive) > Cultura-bility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evaluation of the farmers’ communities’ approach to the Slow Food vision, their perception of the Slow Food role in supporting their activity and their appreciation and expectations from participating in the event of Mother Earth were studied. The Unified Theory of Acceptance and Use of Technology (UTAUT) model was adopted in an agro-food sector context. A survey was conducted, 120 questionnaires from farmers attending the Mother Earth in Turin in 2010 were collected. The descriptive statistical analysis showed that both Slow Food membership and participation to Mother Earth Meeting were much appreciated for the support provided to their business and the contribution to a more sustainable and fair development. A positive social, environmental and psychological impact on farmers also resulted. Results showed also an interesting perspective on the possible universality of the Slow Food and Mother Earth values. Farmers declared that Slow Food is supporting them by preserving the biodiversity and orienting them to the use of local resources and reducing the chemical inputs. Many farmers mentioned the language/culture and administration/bureaucratic issues as an obstacle to be a member in the movement and to participate to the event. Participation to Mother Earth gives an opportunity to exchange information with other farmers’ communities and to participate to seminars and debates, helpful for their business development. The absolute majority of positive answers associated to the farmers’ willingness to relate to Slow Food and participate to the next Mother Earth editions negatively influenced the UTAUT model results. A factor analysis showed that the variables associated to the UTAUT model constructs Performance Expectancy and Effort Expectancy were consistent, able to explain the construct variability, and their measurement reliable. Their inclusion in a simplest Technology Acceptance Model could be considered in future researches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite several clinical tests that have been developed to qualitatively describe complex motor tasks by functional testing, these methods often depend on clinicians' interpretation, experience and training, which make the assessment results inconsistent, without the precision required to objectively assess the effect of the rehabilitative intervention. A more detailed characterization is required to fully capture the various aspects of motor control and performance during complex movements of lower and upper limbs. The need for cost-effective and clinically applicable instrumented tests would enable quantitative assessment of performance on a subject-specific basis, overcoming the limitations due to the lack of objectiveness related to individual judgment, and possibly disclosing subtle alterations that are not clearly visible to the observer. Postural motion measurements at additional locations, such as lower and upper limbs and trunk, may be necessary in order to obtain information about the inter-segmental coordination during different functional tests involved in clinical practice. With these considerations in mind, this Thesis aims: i) to suggest a novel quantitative assessment tool for the kinematics and dynamics evaluation of a multi-link kinematic chain during several functional motor tasks (i.e. squat, sit-to-stand, postural sway), using one single-axis accelerometer per segment, ii) to present a novel quantitative technique for the upper limb joint kinematics estimation, considering a 3-link kinematic chain during the Fugl-Meyer Motor Assessment and using one inertial measurement unit per segment. The suggested methods could have several positive feedbacks from clinical practice. The use of objective biomechanical measurements, provided by inertial sensor-based technique, may help clinicians to: i) objectively track changes in motor ability, ii) provide timely feedback about the effectiveness of administered rehabilitation interventions, iii) enable intervention strategies to be modified or changed if found to be ineffective, and iv) speed up the experimental sessions when several subjects are asked to perform different functional tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

in the everyday clinical practice. Having this in mind, the choice of a simple setup would not be enough because, even if the setup is quick and simple, the instrumental assessment would still be in addition to the daily routine. The will to overcome this limit has led to the idea of instrumenting already existing and widely used functional tests. In this way the sensor based assessment becomes an integral part of the clinical assessment. Reliable and validated signal processing methods have been successfully implemented in Personal Health Systems based on smartphone technology. At the end of this research project there is evidence that such solution can really and easily used in clinical practice in both supervised and unsupervised settings. Smartphone based solution, together or in place of dedicated wearable sensing units, can truly become a pervasive and low-cost means for providing suitable testing solutions for quantitative movement analysis with a clear clinical value, ultimately providing enhanced balance and mobility support to an aging population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Negli anni Ottanta si assiste tanto nel vecchio quanto nel nuovo continente alla rinascita del movimento antinucleare. Mentre in Europa l’origine di questa ondata di proteste antinucleari è collegata alla “doppia decisione” NATO del 1979, negli Stati Uniti la genesi si colloca nel contesto dalla mobilitazione dei gruppi ambientalisti in seguito all’incidente alla centrale nucleare di Three Mile Island. Dopo l’elezione di Ronald Reagan, alle proteste contro le applicazioni pacifiche dell’atomo si affiancarono quelle contro la politica nucleare del Paese. La retorica di Reagan, il massiccio piano di riarmo, unitamente al rinnovato deteriorarsi delle relazioni tra USA e URSS contribuirono a diffondere nell’opinione pubblica la sensazione che l’amministrazione Reagan, almeno da un punto di vista teorico, non avesse escluso dalle sue opzioni il ricorso alle armi nucleari nel caso di un confronto con l’URSS. I timori legati a questa percezione produssero una nuova ondata di proteste che assunsero dimensioni di massa grazie alla mobilitazione provocata dalla Nuclear Weapons Freeze Campaign (NWFC). Il target della NWFC era l’ampio programma di riarmo nucleare sostenuto da Reagan, che secondo gli attivisti nucleari, in un quadro di crescenti tensioni internazionali, avrebbe fatto aumentare le possibilità di uno scontro atomico. Per evitare lo scenario dell’olocausto nucleare, la NWFC proponeva «un congelamento bilaterale e verificabile del collaudo, dell’installazione e della produzione di armi nucleari». L’idea del nuclear freeze, che era concepito come un passo per fermare la spirale del riarmo e tentare successivamente di negoziare riduzioni negli arsenali delle due superpotenze, riscosse un tale consenso nell’opinione pubblica americana da indurre l’amministrazione Reagan a formulare una risposta specifica. Durante la primavera del 1982 fu, infatti, creato un gruppo interdipartimentale ad hoc, l’Arms Control Information Policy Group, con il compito di arginare l’influenza della NWFC sull’opinione pubblica americana e formulare una risposta coerente alle critiche del movimento antinucleare.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 3D human movement analysis performed using stereophotogrammetric systems and skin markers, bone pose can only be estimated in an indirect fashion. During a movement, soft tissue deformations make the markers move with respect to the underlying bone generating soft tissue artefact (STA). STA has devastating effects on bone pose estimation and its compensation remains an open question. The aim of this PhD thesis was to contribute to the solution of this crucial issue. Modelling STA using measurable trial-specific variables is a fundamental prerequisite for its removal from marker trajectories. Two STA model architectures are proposed. Initially, a thigh marker-level artefact model is presented. STA was modelled as a linear combination of joint angles involved in the movement. This model was calibrated using ex-vivo and in-vivo STA invasive measures. The considerable number of model parameters led to defining STA approximations. Three definitions were proposed to represent STA as a series of modes: individual marker displacements, marker-cluster geometrical transformations (MCGT), and skin envelope shape variations. Modes were selected using two criteria: one based on modal energy and another on the selection of modes chosen a priori. The MCGT allows to select either rigid or non-rigid STA components. It was also empirically demonstrated that only the rigid component affects joint kinematics, regardless of the non-rigid amplitude. Therefore, a model of thigh and shank STA rigid component at cluster-level was then defined. An acceptable trade-off between STA compensation effectiveness and number of parameters can be obtained, improving joint kinematics accuracy. The obtained results lead to two main potential applications: the proposed models can generate realistic STAs for simulation purposes to compare different skeletal kinematics estimators; and, more importantly, focusing only on the STA rigid component, the model attains a satisfactory STA reconstruction with less parameters, facilitating its incorporation in an pose estimator.