11 resultados para endoscopic sinus surgery
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.
Resumo:
Introduction The “eversion” technique for carotid endarterectomy (e-CEA), that involves the transection of the internal carotid artery at the carotid bulb and its eversion over the atherosclerotic plaque, has been associated with an increased risk of postoperative hypertension possibly due to a direct iatrogenic damage to the carotid sinus fibers. The aim of this study is to assess the long-term effect of the e-CEA on arterial baroreflex and peripheral chemoreflex function in humans. Methods A retrospective review was conducted on a prospectively compiled computerized database of 3128 CEAs performed on 2617 patients at our Center between January 2001 and March 2006. During this period, a total of 292 patients who had bilateral carotid stenosis ≥70% at the time of the first admission underwent staged bilateral CEAs. Of these, 93 patients had staged bilateral e-CEAs, 126 staged bilateral s- CEAs and 73 had different procedures on each carotid. CEAs were performed with either the eversion or the standard technique with routine Dacron patching in all cases. The study inclusion criteria were bilateral CEA with the same technique on both sides and an uneventful postoperative course after both procedures. We decided to enroll patients submitted to bilateral e-CEA to eliminate the background noise from contralateral carotid sinus fibers. Exclusion criteria were: age >70 years, diabetes mellitus, chronic pulmonary disease, symptomatic ischemic cardiac disease or medical therapy with b-blockers, cardiac arrhythmia, permanent neurologic deficits or an abnormal preoperative cerebral CT scan, carotid restenosis and previous neck or chest surgery or irradiation. Young and aged-matched healthy subjects were also recruited as controls. Patients were assessed by the 4 standard cardiovascular reflex tests, including Lying-to-standing, Orthostatic hypotension, Deep breathing, and Valsalva Maneuver. Indirect autonomic parameters were assessed with a non-invasive approach based on spectral analysis of EKG RR interval, systolic arterial pressure, and respiration variability, performed with an ad hoc software. From the analysis of these parameters the software provides the estimates of spontaneous baroreflex sensitivity (BRS). The ventilatory response to hypoxia was assessed in patients and controls by means of classic rebreathing tests. Results A total of 29 patients (16 males, age 62.4±8.0 years) were enrolled. Overall, 13 patients had undergone bilateral e-CEA (44.8%) and 16 bilateral s-CEA (55.2%) with a mean interval between the procedures of 62±56 days. No patient showed signs or symptoms of autonomic dysfunction, including labile hypertension, tachycardia, palpitations, headache, inappropriate diaphoresis, pallor or flushing. The results of standard cardiovascular autonomic tests showed no evidence of autonomic dysfunction in any of the enrolled patients. At spectral analysis, a residual baroreflex performance was shown in both patient groups, though reduced, as expected, compared to young controls. Notably, baroreflex function was better maintained in e-CEA, compared to standard CEA. (BRS at rest: young controls 19.93 ± 2.45 msec/mmHg; age-matched controls 7.75 ± 1.24; e-CEA 13.85 ± 5.14; s-CEA 4.93 ± 1.15; ANOVA P=0.001; BRS at stand: young controls 7.83 ± 0.66; age-matched controls 3.71 ± 0.35; e-CEA 7.04 ± 1.99; s-CEA 3.57 ± 1.20; ANOVA P=0.001). In all subjects ventilation (VÝ E) and oximetry data fitted a linear regression model with r values > 0.8. Oneway analysis of variance showed a significantly higher slope both for ΔVE/ΔSaO2 in controls compared with both patient groups which were not different from each other (-1.37 ± 0.33 compared with -0.33±0.08 and -0.29 ±0.13 l/min/%SaO2, p<0.05, Fig.). Similar results were observed for and ΔVE/ΔPetO2 (-0.20 ± 0.1 versus -0.01 ± 0.0 and -0.07 ± 0.02 l/min/mmHg, p<0.05). A regression model using treatment, age, baseline FiCO2 and minimum SaO2 achieved showed only treatment as a significant factor in explaining the variance in minute ventilation (R2= 25%). Conclusions Overall, we demonstrated that bilateral e-CEA does not imply a carotid sinus denervation. As a result of some expected degree of iatrogenic damage, such performance was lower than that of controls. Interestingly though, baroreflex performance appeared better maintained in e-CEA than in s-CEA. This may be related to the changes in the elastic properties of the carotid sinus vascular wall, as the patch is more rigid than the endarterectomized carotid wall that remains in the e-CEA. These data confirmed the safety of CEA irrespective of the surgical technique and have relevant clinical implication in the assessment of the frequent hemodynamic disturbances associated with carotid angioplasty stenting.
Resumo:
Introduction. Craniopharyngioma (CF) is a malformation of the hypothalamicpituitary region and it is the most common nonglial cerebral tumor in children with an high overall survival rate. In some case severe endocrinologic and metabolic sequelae may occur during follow up. 50% of patients (pts), in particular those with radical removal of suprasellar lesions, develop intractable hyperphagia and morbid obesity, with dyslypidemia and high cardiovascular risk. We studied the auxological and metabolic features of a series of 29 patients (18 males) treated at a mean age of 7,6 years, followed up in our Centre from 1973 to 2008 with a mean follow up of 8,3 years. Patients features at the onset. 62% of pts showed as first symptoms of disease visual impairment and neurological disturbancies (headache); 34% growth arrest; 24% signs of raised intracranial pressure and 7% diabetes insipidus. Diagnosis. Diagnosis of CF was reached finally by TC or MRI scans which showed endo-suprasellar lesion in 23 cases and endosellar tumour in 6 cases. Treatment and outcome. 25/29 pts underwent surgical removal of CF (19 by transcranial approach and 6 by endoscopic surgery); 4 pts underwent stereotactic surgery as first line therapy. 3 pts underwent local irradiation with yttrium-90, 5 pts post surgery radiotherapy. 45% of pts needed more than one treatment procedure. Results. After CF treatment all patients suffered from 3 or more pituitary hormone deficiencies and diabetes insipidus. They underwent promptly substitutive therapy with corticosteroids, l-thyroxine and desmopressin. In 28/29 pts we found growth hormone (GH) deficiency. 20/28 pts started GH substitutive therapy and 15 pts reached final height(FH) near target height(TH). 8 pts were not GH treated for good growth velocity, even without GH, or for tumour residual. They reached in 2 cases FH over TH showing the already known phenomenon of growth without GH. 38% of patients showed BMI SDS >2 SDS at last assessment, in particular pts not GH treated (BMI 2,5 SDS) are more obese than GH treated (BMI 1,2 SDS). Lipid panel of 16 examined pts showed significative differencies among GH treated (9 pts) and not treated (7 pts) with better profile in GH treated ones for Total Cholesterol/C-HDL and C-LDL/C-HDL. We examined intima media thickness of common carotid arteries in 11 pts. 3/4 not GH treated pts showed ultrasonographic abnormalities: calcifications in 2 and plaque in 1 case. Of them 1 pt was only 12,6 years old and already showed hypothalamic obesity with hyperphagia, high HOMA index and dyslipidemia. In the GH treated group (7) we found calcifications in 1 case and a plaque in another one. GH therapy was started in the young pt with carotid calcifications, with good improvement within 6 months of treatment. 5/29 pts showed hypothalamic obesity, related to hypothalamic damage (type of surgical treatment, endo-suprasellar primitive lesion, recurrences). 48% of patients recurred during follow up ( mean time from treatment: 3 years) and underwent, in some cases up to 4 transcranial surgical treatments. GH seems not to increase recurrence rate since 40% of GH treated recurred vs 66,6% of not GH treated pts. Discussion. Our data show the extereme difficulties that occur during follow up of craniopharyngioma treated patients. GH therapy should be offered to all patients even with good growth velocity after CF treatment, to avoid dislypidemia and reduce cardiovascular risk. The optimal therapy is not completely understood and whether gross tumor removal or partial surgery is the best option remains to be decided only on one patient tumour features and hypothalamic involvement. In conclusion the gold standard treatment of CF remains complete tumour removal, when feasible, or partial resection to preserve hypothalamic function in endosuprasellar large neoplasms.
Resumo:
Background: Almost 10-15% of patients with active Ulcerative Colitis are refractory to conventional therapy. Infliximab is a treatment of proven efficacy in this group of patients. Aims: To evaluate the role of Inliximab in inducing and maintaining remission in patients with chronically active moderate-severe Ulcerative Colitis. Materials and methods: 53 patients were enrolled, 47 patients entered the study and were treated with a dose of 5 mg/kg. The remission was evaluated through endoscopy and clinical criteria. (Mayo Score). The primary endpoint were clinical and endoscopic remission in moderate-severe Ulcerative Colitis refractory to standard therapy, the secondary out point was the maintenance of remission in the long period. Results: 47 patients started the study, 43 completed the study, 4 dropped out for worsening disease or adverse events; 27 patients were treated with 3 infusions, 9 patients with 4 infusions, 7 patients with > o = 5 infusions. 34 /47 patients (72.3%) were responders 12 (25.5%) improved their symptoms, 22 ( 46.8%) were in remission after the treatment. Among the responders, 21/34 (61.8%) stopped the steroid therapy after 3 infusions, the others reduced the dose or maintained just topic therapy. 13/47 patients (27.7%) were non responders (p <0.001). After 3 months all 22 patients which had reached remission maintained low Mayo Score; 10/12 (83.3%) patients with clinical response maintained their low score, 2 relapsed . Conclusions: Infliximab is a valid therapy for the treatment of Ulcerative Colitis and can avoid surgery in selected patients.
Resumo:
The dramatic impact that vascular diseases have on human life quality and expectancy nowadays is the reason why both medical and scientific communities put great effort in discovering new and effective ways to fight vascular pathologies. Among the many different treatments, endovascular surgery is a minimally-invasive technique that makes use of X-ray fluoroscopy to obtain real-time images of the patient during interventions. In this context radiopaque biomaterials, i.e. materials able to absorb X-ray radiation, play a fundamental role as they are employed both to enhance visibility of devices during interventions and to protect medical staff and patients from X-ray radiations. Organic-inorganic hybrids are materials that combine characteristics of organic polymers with those of inorganic metal oxides. These materials can be synthesized via the sol-gel process and can be easily applied as thin coatings on different kinds of substrates. Good radiopacity of organic-inorganic hybrids has been recently reported suggesting that these materials might find applications in medical fields where X-ray absorption and visibility is required. The present PhD thesis aimed at developing and characterizing new radiopaque organic-inorganic hybrid materials that can find application in the vascular surgery field as coatings for the improvement of medical devices traceability as well as for the production of X-ray shielding objects and garments. Novel organic-inorganic hybrids based on different polyesters (poly-lactic acid and poly-ε-caprolactone) and polycarbonate (poly-trimethylene carbonate) as the polymeric phase and on titanium oxide as the inorganic phase were synthesized. Study of the phase interactions in these materials allowed to demonstrate that Class II hybrids (where covalent bonds exists between the two phases) can be obtained starting from any kind of polyester or polycarbonate, without the need of polymer pre-functionalization, thanks to the occurrence of transesterification reactions operated by inorganic molecules on ester and carbonate moieties. Polyester based hybrids were successfully coated via dip coating on different kinds of textiles. Coated textiles showed improved radiopacity with respect to the plain fabric while remaining soft to the touch. The hybrid was able to coat single fibers of the yarn rather than coating the yarn as a whole. Openings between yarns were maintained and therefore fabric breathability was preserved. Such coatings are promising for the production of light-weight garments for X-ray protection of medical staff during interventional fluoroscopy, which will help preventing pathologies that stem from chronic X-ray exposure. A means to increase the protection capacity of hybrid-coated fabrics was also investigated and implemented in this thesis. By synthesizing the hybrid in the presence of a suspension of radiopaque tantalum nanoparticles, PDMS-titania hybrid materials with tunable radiopacity were developed and were successfully applied as coatings. A solution for enhancing medical device radiopacity was also successfully investigated. High metal radiopacity was associated with good mechanical and protective properties of organic-inorganic hybrids in the form of a double-layer coating. Tantalum was employed as the constituent of the first layer deposited on sample substrates by means of a sputtering technique. The second layer was composed of a hybrid whose constituents are well-known biocompatible organic and inorganic components, such as the two polymers PCL and PDMS, and titanium oxide, respectively. The metallic layer conferred to the substrate good X-ray visibility. A correlation between radiopacity and coating thickness derived during this study allows to tailor radiopacity simply by controlling the metal layer sputtering deposition time. The applied metal deposition technique also permits easy shaping of the radiopaque layer, allowing production of radiopaque markers for medical devices that can be unambiguously identified by surgeons during implantation and in subsequent radiological investigations. Synthesized PCL-titania and PDMS-titania hybrids strongly adhered to substrates and show good biocompatibility as highlighted by cytotoxicity tests. The PDMS-titania hybrid coating was also characterized by high flexibility that allows it to stand large substrate deformations without detaching nor cracking, thus being suitable for application on flexible medical devices.
Resumo:
A Micro-opto-mechanical systems (MOMS) based technology for the fabrication of ultrasonic probes on optical fiber is presented. Thanks to the high miniaturization level reached, the realization of an ultrasonic system constituted by ultrasonic generating and detecting elements, suitable for minimally invasive applications or Non Destructive Evaluation (NDE) of materials at high resolution, is demonstrated. The ultrasonic generation is realized by irradiating a highly absorbing carbon film patterned on silicon micromachined structures with a nanosecond pulsed laser source, generating a mechanical shock wave due to the thermal expansion of the film induced by optical energy conversion into heat. The short duration of the pulsed laser, together with an appropriate emitter design, assure high frequency and wide band ultrasonic generation. The acoustic detection is also realized on a MOMS device using an interferometric receiver, fabricated with a Fabry-Perot optical cavity realized by means of a patterned SU-8 and two Al metallization levels. In order to detect the ultrasonic waves, the cavity is interrogated by a laser beam measuring the reflected power with a photodiode. Various issues related to the design and fabrication of these acoustic probes are investigated in this thesis. First, theoretical models are developed to characterize the opto-acoustic behavior of the devices and estimate their expected acoustic performances. Tests structures are realized to derive the relevant physical parameters of the materials constituting the MOMS devices and determine the conditions theoretically assuring the best acoustic emission and detection performances. Moreover, by exploiting the models and the theoretical results, prototypes of acoustic probes are designed and their fabrication process developed by means of an extended experimental activity.
Resumo:
Critical lower limb ischemia is a severe disease. A common approach is infrainguinal bypass. Synthetic vascular prosthesis, are good conduits in high-flow low-resistance conditions but have difficulty in their performance as small diameter vessel grafts. A new approach is the use of native decellularized vascular tissues. Cell-free vessels are expected to have improved biocompatibility when compared to synthetic and are optimal natural 3D matrix templates for driving stem cell growth and tissue assembly in vivo. Decellularization of tissues represent a promising field for regenerative medicine, with the aim to develop a methodology to obtain small-diameter allografts to be used as a natural scaffold suited for in vivo cell growth and pseudo-tissue assembly, eliminating failure caused from immune response activation. Material and methods. Umbilical cord-derived mesenchymal cells isolated from human umbilical cord tissue were expanded in advanced DMEM. Immunofluorescence and molecular characterization revealed a stem cell profile. A non-enzymatic protocol, that associate hypotonic shock and low-concentration ionic detergent, was used to decellularize vessel segments. Cells were seeded cell-free scaffolds using a compound of fibrin and thrombin and incubated in DMEM, after 4 days of static culture they were placed for 2 weeks in a flow-bioreactor, mimicking the cardiovascular pulsatile flow. After dynamic culture, samples were processed for histological, biochemical and ultrastructural analysis. Discussion. Histology showed that the dynamic culture cells initiate to penetrate the extracellular matrix scaffold and to produce components of the ECM, as collagen fibres. Sirius Red staining showed layers of immature collagen type III and ultrastructural analysis revealed 30 nm thick collagen fibres, presumably corresponding to the immature collagen. These data confirm the ability of cord-derived cells to adhere and penetrate a natural decellularized tissue and to start to assembly into new tissue. This achievement makes natural 3D matrix templates prospectively valuable candidates for clinical bypass procedures
Resumo:
The aim of this PhD thesis " Simulation Guided Navigation in cranio- maxillo- facial surgery : a new approach to Improve intraoperative three-dimensional accuracy and reproducibility during surgery ." was at the center of its attention the various applications of a method introduced by our School in 2010 and has as its theme the increase of interest of reproducibility of surgical programs through methods that in whole or in part are using intraoperative navigation. It was introduced in Orthognathic Surgery Validation a new method for the interventions carried out according to the method Simulation Guided Navigation in facial deformities ; was then analyzed the method of three-dimensional control of the osteotomies through the use of templates and cutting of plates using the method precontoured CAD -CAM and laser sintering . It was finally proceeded to introduce the method of piezonavigated surgery in the various branches of maxillofacial surgery . These studies have been subjected to validation processes and the results are presented .
Resumo:
The aim of the Research of this Ph D Project is to improve the medical management after surgery for advanced heart failure, both after left ventricular assist devices (LVAD) implantation, and after heart transplantation in the long-term. Regarding heart transplantation (HTx), the Research Project is focused on diagnostics, classification, prevention and treatment of cardiac allograft vasculopathy (CAV), and on treatment of post-HTx cancers; the results are presented in the first part of this Thesis. In particular, the main aspect investigated are the prognostic role of information derived from coronary angiography, coronary tomography and intravascular ultrasound, and the different sensitivity of these techniques in predicting outcomes and in diagnosing CAV. Moreover, the role of mTOR inhibitors on CAV prevention or treatment is investigated, both alone and in combination with different anti-CMV prevention strategies, as well as the impact of mTOR inhibitors on clinical outcomes in the long term. Regarding LVAD, the main focus is on the role of transthoracic echocardiography in the management of patients with a continuous-flow, centrifugal, intrapericardial pump (HVAD, Heartware); this section is reported in the second part of this Thesis. The main aspects investigated are the use of echocardiography in patients with HVAD device and its interaction with the information derived from pump curves' analysis in predicting aortic valve opening status, a surrogate of the condition of support provided by the LVAD.
Resumo:
Background: Piezoelectric instrumentation seems to offer 3 important advantages for cutting bone structures. Be more precise because it is produced by micro-vibrations from the cutting insert. Be safer because the ultrasonic frequency used does not affect soft tissue. Thirdly, the less invasive cutting action produces minor tissue damage and consequently probably a better healing Aim of the Study: The aim of this study is to evaluate the effectiveness of piezoelectric device capability in maxillo-facial surgery, in order to take advantage of these favourable capacity. Material and Methods: Considering the several potential application of the piezoelectric technology in Orthognathic, Oncologic and Extractive surgery, we would like to design protocols in order to verify how this new device can modify the surgical technique, the surgical time, the patients healing and its quality of life. Results: Due to the precise Piezosurgery cut, we can manage the Cad-Cam-Custom Made plates protocol in Oncologic Surgery and in Orthognatic Surgery increasing our percentage of comparison between the 3D preoperative plan and the surgical execution. We also found a better quality of life impaction in Patient who underwent and extractive surgery Conclusion: Piezosurgery device seems to be a strong surgical aid were safe and precise cut are needed and its capability to reduce the discomfort Patients need to be study in deep also in major surgery like Orthognatic and Oncologic surgery.