108 resultados para diagnosi

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hepatitis E is an infectious viral disease with clinical and morphological features of acute hepatitis. The aetiological agent is the Hepatitis E virus (HEV). The disease represents an important Public Health problem in developing countries where is frequently epidemic and primarily transmitted by fecal-oral route. In the last few years, a certain number of sporadic cases have been also described in industrialized countries, Italy included. A swine HEV was first identified in 1997 and is now considered an ubiquitous virus. Human and swine strains from the same geographical region have shown to have a high level of nucleotidic omology and in experimental infections, the possibility of interspecific transmission of swine strains to humans and of human strains to non-human primates has been demonstrated. Furthermore, some seroepidemiological studies have demonstrated that people working in contact with swine have a higher risk to get infected than normal blood donors. Recently, cases of HEV hepatitis have been directly associated to the ingestion of uncooked tissues from pigs, wild boar or deer and today the disease is considered an emerging zoonosis. The aims of this thesis were: evaluate HEV prevalence in Italian swine herds (both in fattening and in breeding animals); investigate the possibility of finding HEV in livers used for human consumption; investigate if there is any correlation between HEV infection and the presence of macroscopical lesions; investigate HEV prevalence in a demographic managed wild boar population; phylogenetically analyse viral strains identified. During an internship period at Veterinary Laboratories Agency (Weybridge, UK), furthermore, swine samples at different stages of production and slurry lagoons have been analysed. Six swine herds located in North Italy have been sampled at different stage of production. The overall prevalence resulted 42%, and both breeding and fattening animals were positive for HEV infection. A longitudinal study has been conducted in a herd across all stages of production until the slaughtering age. Livers have been collected from the animals at the abattoir and 11.8% of them were positive for HEV infection. No correlations have been identified between HEV infection and macroscopical lesions in pigs affected by different pathological conditions. Of 86 wild boars tested 22 (25%) were positive for HEV. Of the swine tested in UK 21,5 % and 2 of the 9 slurry lagoons (22,2%) were positive for HEV infection. All the strains identified belonged to genotype 3 and showed high percentages of nucleotidic identity with humans and swine strains identified in Europe. The high prevalence detected in these studies confirms the widespread diffusion of HEV in swine populations in Italy and in UK. Phylogenetical analysis of identified strains, similar to those identified in autochthonous human hepatitis E cases of the same geographical area, confirm the hypothesis that pigs can be a font of zoonotical infection. The finding that a fraction of the livers inserted in the food chain are positive for HEV infection it’s of some concern for Public Health. The finding of a high HEV prevalence in all examined farms, together with the observation that infection may be sub-clinical and affect animals at slaughtering age, raise concern because of the possible risk of transmission of HEV to humans by either direct contact with infected pigs, indirect contact with environment and working instruments contaminated with pig feces, or ingestion of contaminated undercooked meat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increasingly stringent exhaust emission limits and higher fuel economy are the main drivers of the engine development process. As a consequence, the complexity of the propulsion units and its subsystems increase, due to the extensive use of sensors and actuators needed to obtain a precise control over the combustion phase. Since engine calibration process consumes most of the development time, new tools and methodologies are needed to shorten the development time and increase the performance attainable. Real time combustion analysis, based on the in-cylinder pressure signal, can significantly improve the calibration of the engine control strategies and the development of new algorithms, giving instantaneous feedback on the engine behavior. A complete combustion analysis and diagnosis system has been developed, capable of evaluating the most important indicators about the combustion process, such as indicated mean effective pressure, heat release, mass fraction burned and knock indexes. Such a tool is built on top of a flexible, modular and affordable hardware platform, capable of satisfying the requirements needed for accuracy and precision, but also enabling the use directly on-board the vehicle, due to its small form factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

“Naturally occurring cancers in pet dogs and humans share many features, including histological appearance, tumour genetics, molecular targets, biological behaviour and response to conventional therapies. Studying dogs with cancer is likely to provide a valuable perspective that is distinct from that generated by the study of human or rodent cancers alone. The value of this opportunity has been increasingly recognized in the field of cancer research for the identification of cancer-associated genes, the study of environmental risk factors, understanding tumour biology and progression, and, perhaps most importantly, the evaluation and development of novel cancer therapeutics”.(Paoloni and Khanna, 2008) In last years, the author has investigated some molecular features of cancer in dogs. The Thesis is articulated in two main sections. In section 1, the preliminary results of a research project aimed at investigating the role of somatic mutations of Ataxia-Telangiectasia mutated (ATM) gene in predisposing to cancer in boxer dogs, are presented. The canine boxer breed may be considered an unique opportunity to disclose the role of ATM somatic mutation since boxer dogs are known to be dramatically susceptible to cancer and since they may be considered a closed gene pool. Furthermore, dogs share with human the some environment. Overall, the abovementioned features could be considered extremely useful for our purposes. In the section 2, the results of our studies aimed at setting up accurate and sensitive molecular assays for diagnosing and assessing minimal residual disease in lymphoproliferative disorders of dogs, are presented. The results of those molecular assay may be directly translated in the field of Veterinary practice as well as the may be used to improve our objective evaluation of new investigational drugs effectiveness in canine cancer trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: One major problem in counselling couples with a prenatal diagnosis of a correctable fetal anomaly is the ability to exclude associated malformations that may modify the prognosis. Our aim was to assess the precision of fetal sonography in identifying isolated malformations. METHODS: We retrospectively reviewed the prenatal and postnatal records of our center for cases with a prenatal diagnosis of an isolated fetal anomaly in the period 2002-2007. RESULTS: The antenatal diagnosis of an isolated malformation was made in 284 cases. In one of this cases the anomaly disappeared in utero. Of the remaining cases, the prenatal diagnosis was confirmed after birth in 251 (88.7%). In 8 fetuses (7 with a suspected coarctation of the aorta, 1 with ventricular septal defect) the prenatal diagnosis was not confirmed. In 24 fetuses (8.5%) additional malformations were detected at postnatal or post-mortem. In 16 of these cases the anomalies were mild or would not have changed the prognosis. In 8 cases (2.8%) severe anomalies were present (1 hypoplasia of the corpus callosum with ventriculomegaly, 1 tracheal agenesis, 3 cases with multiple anomalies, 1 Opitz Syndrome, 1 with CHARGE Syndrome, 1 COFS Syndrome). Two of these infants died. CONCLUSIONS: the prenatal diagnosis of an isolated fetal anomaly is highly reliable. However, the probability that additional malformations will go undetected albeit small remains tangible. In our experience, it was 2.8%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’ecografia è la metodica diagnostica più utilizzata come screening e follow-up nei pazienti epatopatici con o senza lesioni focali e questo grazie alle sue peculiari caratteristiche, che sono date dall’essere real-time, maneggevole, priva di radiazioni ionizzanti e con bassi costi. Tuttavia tale metodica se confrontata con la TC o la RMN, può avere importanti limiti, quali l’impossibilità di visualizzare piccole lesioni localizzate in aree anatomicamente “difficili” o in pazienti obesi, che sono già state identificate con altre tecniche, come la TC o la RMN. Per superare queste limitazioni sono stati introdotti dei sistemi di “fusione d’immagine” che consentono di sincronizzare in tempo reale una metodica real time con bassa risoluzione spaziale come l’ecografia ed una statica ad alta risoluzione come la TC o la RMN. Ciò si ottiene creando attorno al paziente un piccolo campo elettromagnetico costituito da un generatore e da un rilevatore applicato al trasduttore ecografico ed introducendo in un computer abbinato all’ecografo il “volume rendering” dell’addome del paziente ottenuto mediante TC multistrato o RM. Il preciso “ appaiamento spaziale “ delle due metodiche si ottiene individuando in entrambe lo stesso piano assiale di riferimento e almeno 3-4 punti anatomici interni. Tale sistema di fusione d’immagine potrebbe essere molto utile in campo epatologico nella diagnostica non invasiva del piccolo epatocarcinoma, che secondo le ultime linee guida, nei noduli di dimensioni fra 1 e 2 cm, richiede una concordanza nel comportamento contrastografico della lesione in almeno due tecniche d’immagine. Lo scopo del nostro lavoro è stato pertanto quello di valutare, in pazienti epatopatici, il contributo che tale sistema può dare nell’identificazione e caratterizzazione di lesioni inferiori a 20 mm, che erano già state identificate alla TC o alla RMN come noduli sospetti per HCC, ma che non erano stati visualizzati in ecografia convenzionale. L’eventuale re-identificazione con l’ecografia convenzionale dei noduli sospetti per essere HCC, può permettere di evitare, alla luce dei criteri diagnostici non invasivi un’ ulteriore tecnica d’immagine ed eventualmente la biopsia. Pazienti e Metodi: 17 pazienti cirrotici (12 Maschi; 5 Femmine), con età media di 68.9 +/- 6.2 (SD) anni, in cui la TC e la RMN con mezzo di contrasto avevano identificato 20 nuove lesioni focali epatiche, inferiori a 20 mm (13,6 +/- 3,6 mm), sospette per essere epatocarcinomi (HCC), ma non identificate all’ecografia basale (eseguita in cieco rispetto alla TC o alla RMN) sono stati sottoposti ad ecografia senza e con mezzo di contrasto, focalizzata su una zona bersaglio identificata tramite il sistema di fusione d’immagini, che visualizza simultaneamente le immagini della TC e della RMN ricostruite in modalità bidimensionale ( 2D), tridimensionale ( 3 D) e real-time. La diagnosi finale era stata stabilita attraverso la presenza di una concordanza diagnostica, secondo le linee guida internazionali o attraverso un follow-up nei casi di discordanza. Risultati: Una diagnosi non invasiva di HCC è stata raggiunta in 15/20 lesioni, inizialmente sospettate di essere HCC. Il sistema di fusione ha identificato e mostrato un comportamento contrastografico tipico in 12/15 noduli di HCC ( 80%) mentre 3/15 HCC (20%) non sono stati identificati con il sistema di fusione d’immagine. Le rimanenti 5/20 lesioni non sono state visualizzate attraverso i sistemi di fusione d’immagine ed infine giudicate come falsi positivi della TC e della RMN, poiché sono scomparse nei successivi mesi di follow-up e rispettivamente dopo tre, sei, nove, dodici e quindici mesi. Conclusioni: I nostri risultati preliminari mostrano che la combinazione del sistema di fusione dell’immagine associata all’ecografia senza e con mezzo di contrasto (CEUS), migliora il potenziale dell’ecografia nell’identificazione e caratterizzazione dell’HCC su fegato cirrotico, permettendo il raggiungimento di una diagnosi, secondo criteri non invasivi e slatentizzazndo casi di falsi positivi della TC e della RMN.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduzione La diagnosi di HCC con le tecniche di immagine ed in particolare con CEUS su fegato cirrotico secondo le ultime linee guida prevede un comportamento contrastografico di ipervascolarizzazione nella fase arteriosa e wash-out nella fase tardiva. CEUS è ormai una metodica accettata per la diagnosi ma il wash out nella fase tardiva presenta notevoli difficoltà nel determinare il comportamento contrastografico in quanto valutato soggettivamente su display, infatti il giudizio di tale fase dipende molto dall’operatore e non è rarissimo che nascono discordanza tra operatori anche per piccole differenze. Recentemente è stato proposto un nuovo software(SonoLiver, Bracco, Italy) in grado di quantificare la perfusione delle lesione durante CEUS. Pertanto lo scopo di questo studio pilota è quello di valutare l’impatto di SonoLiver nel rilevare caratteristiche contrastografiche tipiche dell’HCC e valutare la riproducibilità tra due operatori. Pazienti e metodi: Sono stati presi in considerazione 20 noduli (di dimensioni tra 12-95 mm) con diagnosi di HCC in 20 pazienti con cirrosi . La CEUS è stata valutata dapprima ad occhio nudo su display e successivamente con le curve ottenute con DVP da parte di due operatori diversi in cieco, dopo un periodo di formazione adeguata. Sono state quindi analizzate le performance di ciascuna metodica sia in termini di variabilità tra i due operatori che la variabilità tra CEUS ad occhio nudo e CEUS con SonoLiver dello stesso operatore. Risultati:Operatore 1 ha rilevato ipervascolarizzazione in fase arteriosa in 17 su 20 pazienti con valutazione ad occhio nudo su schermo e su 19/20 con le curve ottenute con DVP (+10% sensibilità) mentre operatore 2 ha rilevato ipervascolarizzazione in fase arteriosa19/20 pazienti sia con valutazione ad occhio nudo che con le curve DVP. Nella fase tardiva il wash-out è stato rilevato in 7/20 ad occhio nudo e 10/20 pazienti con le curve DVP (sensibilità aumenta da 35% a 50%) mentre operatore 2 ha rilevato rispettivamente 8/20 e 11/20 (sensibilità aumenta da 40% a 55%). La riproducibilità tra i due operatori rimane invariata con la valutazione di Sonoliver sia nella fase arteriosa che nella fase tardiva. Conclusione:La quantificazione perfusionale con SonoLiver sembra essere uno strumento promettente nella diagnosi di HCC su fegato cirrotico, aumentando aspetti tipici contrastografici.