11 resultados para contaminants of emerging concern (CECs)

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pharmaceuticals are useful tools to prevent and treat human and animal diseases. Following administration, a significant fraction of pharmaceuticals is excreted unaltered into faeces and urine and may enter the aquatic ecosystem and agricultural soil through irrigation with recycled water, constituting a significant source of emerging contaminants into the environment. Understanding major factors influencing their environmental fate is consequently needed to value the risk, reduce contamination, and set up bioremediation technologies. The antiviral drug Tamiflu (oseltamivir carboxylate, OC) has received recent attention due to the potential use as a first line defence against H5N1 and H1N1 influenza viruses. Research has shown that OC is not removed during conventional wastewater treatments, thus having the potential to enter surface water bodies. A series of laboratory experiments investigated the fate and the removal of OC in surface water systems in Italy and Japan and in a municipal wastewater treatment plant. A preliminary laboratory study investigated the persistence of the active antiviral drug in water samples from an irrigation canal in northern Italy (Canale Emiliano Romagnolo). After an initial rapid decrease, OC concentration slowly decreased during the remaining incubation period. Approximately 65% of the initial OC amount remained in water at the end of the 36-day incubation period. A negligible amount of OC was lost both from sterilized water and from sterilized water/sediment samples, suggesting a significant role of microbial degradation. Stimulating microbial processes by the addition of sediments resulted in reduced OC persistence. Presence of OC (1.5 μg mL-1) did not significantly affect the metabolic potential of the water microbial population, that was estimated by glyphosate and metolachlor mineralization. In contrast, OC caused an initial transient decrease in the size of the indigenous microbial population of water samples. A second laboratory study focused on basic processes governing the environmental fate of OC in surface water from two contrasting aquatic ecosystems of northern Italy, the River Po and the Venice Lagoon. Results of this study confirmed the potential of OC to persist in surface water. However, the addition of 5% of sediments resulted in rapid OC degradation. The estimated half-life of OC in water/sediment of the River Po was 15 days. After three weeks of incubation at 20 °C, more than 8% of 14C-OC evolved as 14CO2 from water/sediment samples of the River Po and Venice Lagoon. OC was moderately retained onto coarse sediments from the two sites. In water/sediment samples of the River Po and Venice Lagoon treated with 14C-OC, more than 30% of the 14C-residues remained water-extractable after three weeks of incubation. The low affinity of OC to sediments suggests that the presence of sediments would not reduce its bioavailability to microbial degradation. Another series of laboratory experiments investigated the fate and the removal of OC in two surface water ecosystems of Japan and in the municipal wastewater treatment plant of the city of Bologna, in Northern Italy. The persistence of OC in surface water ranged from non-detectable degradation to a half-life of 53 days. After 40 days, less than 3% of radiolabeled OC evolved as 14CO2. The presence of sediments (5%) led to a significant increase of OC degradation and of mineralization rates. A more intense mineralization was observed in samples of the wastewater treatment plant when applying a long incubation period (40 days). More precisely, 76% and 37% of the initial radioactivity applied as 14C-OC was recovered as 14CO2 from samples of the biological tank and effluent water, respectively. Two bacterial strains growing on OC as sole carbon source were isolated and used for its removal from synthetic medium and environmental samples, including surface water and wastewater. Inoculation of water and wastewater samples with the two OC-degrading strains showed that mineralization of OC was significantly higher in both inoculated water and wastewater, than in uninoculated controls. Denaturing gradient gel electrophoresis and quantitative PCR analysis showed that OC would not affect the microbial population of surface water and wastewater. The capacity of the ligninolytic fungus Phanerochaete chrysosporium to degrade a wide variety of environmentally persistent xenobiotics has been largely reported in literature. In a series of laboratory experiments, the efficiency of a formulation using P. chrysosporium was evaluated for the removal of selected pharmaceuticals from wastewater samples. Addition of the fungus to samples of the wastewater treatment plant of Bologna significantly increased (P < 0.05) the removal of OC and three antibiotics, erythromycin, sulfamethoxazole, and ciprofloxacin. Similar effects were also observed in effluent water. OC was the most persistent of the four pharmaceuticals. After 30 days of incubation, approximately two times more OC was removed in bioremediated samples than in controls. The highest removal efficiency of the formulation was observed with the antibiotic ciprofloxacin. The studies included environmental aspects of soil contamination with two emerging veterinary contaminants, such as doramectin and oxibendazole, wich are common parasitic treatments in cattle farms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The running innovation processes of the microwave transistor technologies, used in the implementation of microwave circuits, have to be supported by the study and development of proper design methodologies which, depending on the applications, will fully exploit the technology potentialities. After the choice of the technology to be used in the particular application, the circuit designer has few degrees of freedom when carrying out his design; in the most cases, due to the technological constrains, all the foundries develop and provide customized processes optimized for a specific performance such as power, low-noise, linearity, broadband etc. For these reasons circuit design is always a “compromise”, an investigation for the best solution to reach a trade off between the desired performances. This approach becomes crucial in the design of microwave systems to be used in satellite applications; the tight space constraints impose to reach the best performances under proper electrical and thermal de-rated conditions, respect to the maximum ratings provided by the used technology, in order to ensure adequate levels of reliability. In particular this work is about one of the most critical components in the front-end of a satellite antenna, the High Power Amplifier (HPA). The HPA is the main power dissipation source and so the element which mostly engrave on space, weight and cost of telecommunication apparatus; it is clear from the above reasons that design strategies addressing optimization of power density, efficiency and reliability are of major concern. Many transactions and publications demonstrate different methods for the design of power amplifiers, highlighting the availability to obtain very good levels of output power, efficiency and gain. Starting from existing knowledge, the target of the research activities summarized in this dissertation was to develop a design methodology capable optimize power amplifier performances complying all the constraints imposed by the space applications, tacking into account the thermal behaviour in the same manner of the power and the efficiency. After a reminder of the existing theories about the power amplifier design, in the first section of this work, the effectiveness of the methodology based on the accurate control of the dynamic Load Line and her shaping will be described, explaining all steps in the design of two different kinds of high power amplifiers. Considering the trade-off between the main performances and reliability issues as the target of the design activity, we will demonstrate that the expected results could be obtained working on the characteristics of the Load Line at the intrinsic terminals of the selected active device. The methodology proposed in this first part is based on the assumption that designer has the availability of an accurate electrical model of the device; the variety of publications about this argument demonstrates that it is so difficult to carry out a CAD model capable to taking into account all the non-ideal phenomena which occur when the amplifier operates at such high frequency and power levels. For that, especially for the emerging technology of Gallium Nitride (GaN), in the second section a new approach for power amplifier design will be described, basing on the experimental characterization of the intrinsic Load Line by means of a low frequency high power measurements bench. Thanks to the possibility to develop my Ph.D. in an academic spin-off, MEC – Microwave Electronics for Communications, the results of this activity has been applied to important research programs requested by space agencies, with the aim support the technological transfer from universities to industrial world and to promote a science-based entrepreneurship. For these reasons the proposed design methodology will be explained basing on many experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le sostanze perfluoralchiliche (PFAS), composti fluorurati ampiamente utilizzati negli ultimi anni in diverse applicazioni industriali e commerciali, sono ritrovati diffusamente nell’ambiente e in diverse specie animali. Recentemente i PFAS hanno destato preoccupazione anche per la salute umana. Il rischio di esposizione è principalmente legato alla dieta (i prodotti ittici sembrano essere gli alimenti più contaminati). Lo scopo di questo lavoro è stato quello di valutare la presenza del perfluorottanosulfonato (PFOS) e dell’acido perfluorottanoico (PFOA), in diverse matrici alimentari: latte vaccino commercialmente disponibile in Italia, latte materno italiano, diverse specie di pesce commercialmente disponibili in Italia e 140 branzini di diverse aree (principalmente Mediterraneo). I campioni di latte sono stati trattati con estrazione liquido-liquido seguita da due fasi di purificazione mediante cartucce SPE prima dell’iniezione nell’UPLC-MS/MS. L’analisi del latte vaccino ha evidenziato una contaminazione diffusa di PFOS, ma a basse concentrazioni (fino a 97 ng/L), mentre il PFOA è stato ritrovato raramente. In questo studio, in grado di individuare anche i livelli delle ultra-tracce, sono state osservate nel latte materno concentrazioni di 15-288 ng/L per il PFOS e di 24-241 ng/LPFOA. Le concentrazioni e le frequenze più alte, per entrambi i PFAS, sono stati ritrovate in campioni di latte forniti da donne primipare, suggerendo un rischio di esposizione per i primogeniti. Il metodo utilizzato per i campioni di pesce era basato su un’estrazione con solvente organico seguita da due fasi di purificazione: una con i sali e una con fase solida dispersiva. L’estratto, analizzato in UPLC-MS/MS, ha confermato la contaminazione di questa matrice a livelli significativi, ma anche l’alta variabilità delle concentrazioni misurate. Il monitoraggio monospecie ha mostrato una contaminazione rilevante (PFOS 11,1- > 10000 ng/L; PFOA < 9-487 ng/L), soprattutto nei branzini pescati, rispetto a quelli allevati.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hepatitis E is an infectious viral disease with clinical and morphological features of acute hepatitis. The aetiological agent is the Hepatitis E virus (HEV). The disease represents an important Public Health problem in developing countries where is frequently epidemic and primarily transmitted by fecal-oral route. In the last few years, a certain number of sporadic cases have been also described in industrialized countries, Italy included. A swine HEV was first identified in 1997 and is now considered an ubiquitous virus. Human and swine strains from the same geographical region have shown to have a high level of nucleotidic omology and in experimental infections, the possibility of interspecific transmission of swine strains to humans and of human strains to non-human primates has been demonstrated. Furthermore, some seroepidemiological studies have demonstrated that people working in contact with swine have a higher risk to get infected than normal blood donors. Recently, cases of HEV hepatitis have been directly associated to the ingestion of uncooked tissues from pigs, wild boar or deer and today the disease is considered an emerging zoonosis. The aims of this thesis were: evaluate HEV prevalence in Italian swine herds (both in fattening and in breeding animals); investigate the possibility of finding HEV in livers used for human consumption; investigate if there is any correlation between HEV infection and the presence of macroscopical lesions; investigate HEV prevalence in a demographic managed wild boar population; phylogenetically analyse viral strains identified. During an internship period at Veterinary Laboratories Agency (Weybridge, UK), furthermore, swine samples at different stages of production and slurry lagoons have been analysed. Six swine herds located in North Italy have been sampled at different stage of production. The overall prevalence resulted 42%, and both breeding and fattening animals were positive for HEV infection. A longitudinal study has been conducted in a herd across all stages of production until the slaughtering age. Livers have been collected from the animals at the abattoir and 11.8% of them were positive for HEV infection. No correlations have been identified between HEV infection and macroscopical lesions in pigs affected by different pathological conditions. Of 86 wild boars tested 22 (25%) were positive for HEV. Of the swine tested in UK 21,5 % and 2 of the 9 slurry lagoons (22,2%) were positive for HEV infection. All the strains identified belonged to genotype 3 and showed high percentages of nucleotidic identity with humans and swine strains identified in Europe. The high prevalence detected in these studies confirms the widespread diffusion of HEV in swine populations in Italy and in UK. Phylogenetical analysis of identified strains, similar to those identified in autochthonous human hepatitis E cases of the same geographical area, confirm the hypothesis that pigs can be a font of zoonotical infection. The finding that a fraction of the livers inserted in the food chain are positive for HEV infection it’s of some concern for Public Health. The finding of a high HEV prevalence in all examined farms, together with the observation that infection may be sub-clinical and affect animals at slaughtering age, raise concern because of the possible risk of transmission of HEV to humans by either direct contact with infected pigs, indirect contact with environment and working instruments contaminated with pig feces, or ingestion of contaminated undercooked meat.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In such territories where food production is mostly scattered in several small / medium size or even domestic farms, a lot of heterogeneous residues are produced yearly, since farmers usually carry out different activities in their properties. The amount and composition of farm residues, therefore, widely change during year, according to the single production process periodically achieved. Coupling high efficiency micro-cogeneration energy units with easy handling biomass conversion equipments, suitable to treat different materials, would provide many important advantages to the farmers and to the community as well, so that the increase in feedstock flexibility of gasification units is nowadays seen as a further paramount step towards their wide spreading in rural areas and as a real necessity for their utilization at small scale. Two main research topics were thought to be of main concern at this purpose, and they were therefore discussed in this work: the investigation of fuels properties impact on gasification process development and the technical feasibility of small scale gasification units integration with cogeneration systems. According to these two main aspects, the present work was thus divided in two main parts. The first one is focused on the biomass gasification process, that was investigated in its theoretical aspects and then analytically modelled in order to simulate thermo-chemical conversion of different biomass fuels, such as wood (park waste wood and softwood), wheat straw, sewage sludge and refuse derived fuels. The main idea is to correlate the results of reactor design procedures with the physical properties of biomasses and the corresponding working conditions of gasifiers (temperature profile, above all), in order to point out the main differences which prevent the use of the same conversion unit for different materials. At this scope, a gasification kinetic free model was initially developed in Excel sheets, considering different values of air to biomass ratio and the downdraft gasification technology as particular examined application. The differences in syngas production and working conditions (process temperatures, above all) among the considered fuels were tried to be connected to some biomass properties, such elementary composition, ash and water contents. The novelty of this analytical approach was the use of kinetic constants ratio in order to determine oxygen distribution among the different oxidation reactions (regarding volatile matter only) while equilibrium of water gas shift reaction was considered in gasification zone, by which the energy and mass balances involved in the process algorithm were linked together, as well. Moreover, the main advantage of this analytical tool is the easiness by which the input data corresponding to the particular biomass materials can be inserted into the model, so that a rapid evaluation on their own thermo-chemical conversion properties is possible to be obtained, mainly based on their chemical composition A good conformity of the model results with the other literature and experimental data was detected for almost all the considered materials (except for refuse derived fuels, because of their unfitting chemical composition with the model assumptions). Successively, a dimensioning procedure for open core downdraft gasifiers was set up, by the analysis on the fundamental thermo-physical and thermo-chemical mechanisms which are supposed to regulate the main solid conversion steps involved in the gasification process. Gasification units were schematically subdivided in four reaction zones, respectively corresponding to biomass heating, solids drying, pyrolysis and char gasification processes, and the time required for the full development of each of these steps was correlated to the kinetics rates (for pyrolysis and char gasification processes only) and to the heat and mass transfer phenomena from gas to solid phase. On the basis of this analysis and according to the kinetic free model results and biomass physical properties (particles size, above all) it was achieved that for all the considered materials char gasification step is kinetically limited and therefore temperature is the main working parameter controlling this step. Solids drying is mainly regulated by heat transfer from bulk gas to the inner layers of particles and the corresponding time especially depends on particle size. Biomass heating is almost totally achieved by the radiative heat transfer from the hot walls of reactor to the bed of material. For pyrolysis, instead, working temperature, particles size and the same nature of biomass (through its own pyrolysis heat) have all comparable weights on the process development, so that the corresponding time can be differently depending on one of these factors according to the particular fuel is gasified and the particular conditions are established inside the gasifier. The same analysis also led to the estimation of reaction zone volumes for each biomass fuel, so as a comparison among the dimensions of the differently fed gasification units was finally accomplished. Each biomass material showed a different volumes distribution, so that any dimensioned gasification unit does not seem to be suitable for more than one biomass species. Nevertheless, since reactors diameters were found out quite similar for all the examined materials, it could be envisaged to design a single units for all of them by adopting the largest diameter and by combining together the maximum heights of each reaction zone, as they were calculated for the different biomasses. A total height of gasifier as around 2400mm would be obtained in this case. Besides, by arranging air injecting nozzles at different levels along the reactor, gasification zone could be properly set up according to the particular material is in turn gasified. Finally, since gasification and pyrolysis times were found to considerably change according to even short temperature variations, it could be also envisaged to regulate air feeding rate for each gasified material (which process temperatures depend on), so as the available reactor volumes would be suitable for the complete development of solid conversion in each case, without even changing fluid dynamics behaviour of the unit as well as air/biomass ratio in noticeable measure. The second part of this work dealt with the gas cleaning systems to be adopted downstream the gasifiers in order to run high efficiency CHP units (i.e. internal engines and micro-turbines). Especially in the case multi–fuel gasifiers are assumed to be used, weightier gas cleaning lines need to be envisaged in order to reach the standard gas quality degree required to fuel cogeneration units. Indeed, as the more heterogeneous feed to the gasification unit, several contaminant species can simultaneously be present in the exit gas stream and, as a consequence, suitable gas cleaning systems have to be designed. In this work, an overall study on gas cleaning lines assessment is carried out. Differently from the other research efforts carried out in the same field, the main scope is to define general arrangements for gas cleaning lines suitable to remove several contaminants from the gas stream, independently on the feedstock material and the energy plant size The gas contaminant species taken into account in this analysis were: particulate, tars, sulphur (in H2S form), alkali metals, nitrogen (in NH3 form) and acid gases (in HCl form). For each of these species, alternative cleaning devices were designed according to three different plant sizes, respectively corresponding with 8Nm3/h, 125Nm3/h and 350Nm3/h gas flows. Their performances were examined on the basis of their optimal working conditions (efficiency, temperature and pressure drops, above all) and their own consumption of energy and materials. Successively, the designed units were combined together in different overall gas cleaning line arrangements, paths, by following some technical constraints which were mainly determined from the same performance analysis on the cleaning units and from the presumable synergic effects by contaminants on the right working of some of them (filters clogging, catalysts deactivation, etc.). One of the main issues to be stated in paths design accomplishment was the tars removal from the gas stream, preventing filters plugging and/or line pipes clogging At this scope, a catalytic tars cracking unit was envisaged as the only solution to be adopted, and, therefore, a catalytic material which is able to work at relatively low temperatures was chosen. Nevertheless, a rapid drop in tars cracking efficiency was also estimated for this same material, so that an high frequency of catalysts regeneration and a consequent relevant air consumption for this operation were calculated in all of the cases. Other difficulties had to be overcome in the abatement of alkali metals, which condense at temperatures lower than tars, but they also need to be removed in the first sections of gas cleaning line in order to avoid corrosion of materials. In this case a dry scrubber technology was envisaged, by using the same fine particles filter units and by choosing for them corrosion resistant materials, like ceramic ones. Besides these two solutions which seem to be unavoidable in gas cleaning line design, high temperature gas cleaning lines were not possible to be achieved for the two larger plant sizes, as well. Indeed, as the use of temperature control devices was precluded in the adopted design procedure, ammonia partial oxidation units (as the only considered methods for the abatement of ammonia at high temperature) were not suitable for the large scale units, because of the high increase of reactors temperature by the exothermic reactions involved in the process. In spite of these limitations, yet, overall arrangements for each considered plant size were finally designed, so that the possibility to clean the gas up to the required standard degree was technically demonstrated, even in the case several contaminants are simultaneously present in the gas stream. Moreover, all the possible paths defined for the different plant sizes were compared each others on the basis of some defined operational parameters, among which total pressure drops, total energy losses, number of units and secondary materials consumption. On the basis of this analysis, dry gas cleaning methods proved preferable to the ones including water scrubber technology in al of the cases, especially because of the high water consumption provided by water scrubber units in ammonia adsorption process. This result is yet connected to the possibility to use activated carbon units for ammonia removal and Nahcolite adsorber for chloride acid. The very high efficiency of this latter material is also remarkable. Finally, as an estimation of the overall energy loss pertaining the gas cleaning process, the total enthalpy losses estimated for the three plant sizes were compared with the respective gas streams energy contents, these latter obtained on the basis of low heating value of gas only. This overall study on gas cleaning systems is thus proposed as an analytical tool by which different gas cleaning line configurations can be evaluated, according to the particular practical application they are adopted for and the size of cogeneration unit they are connected to.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Organotin compounds are worldwide diffused environmental contaminants, mainly as consequence of their extensive past use as biocides in antifouling paints. In spite of law restrictions, due to unwanted effects, organotin still persist in waters, being poorly degraded, easily resuspended from sediments and bioaccumulated in exposed organisms. The widespread toxicity and the possible threat to humans, likely to be organotin-exposed through contaminated seafood, make organotin interactions with biomolecules an intriguing biochemical topic, apart from a matter of ecotoxicological concern. Among organotins, tributyltin (TBT) is long known as the most dangerous and abundant chemical species in the Mediterranean Sea. Due to its amphiphilic nature, provided by three lipophilic arms and an electrophilic tin core, TBT can be easily incorporated in biomembranes and affect their functionality. Accordingly, it is known as a membrane-active toxicant and a mitochondrial poison. Up to now the molecular action modes of TBT are still partially unclear and poorly explored in bivalve mollusks, even if the latter play a not neglectable role in the marine trophic chain and efficiently accumulate organotins. The bivalve mollusk Mytilus galloprovincialis, selected for all experiments, is widely cultivated in the Mediterranean and currently used in ecotoxicological studies. Most work of this thesis was devoted to TBT effects on mussel mitochondria, but other possible targets of TBT were also considered. A great deal of literature points out TBT as endocrine disrupter and the masculinization of female marine gastropods, the so-called imposex, currently signals environmental organotin contamination. The hormonal status of TBT-exposed mussels and the possible interaction between hormones and contaminants in modulating microsomal hydroxilases, involved in steroid hormone and organotin detoxification, were the research topics in the period spent in Barcelona (Marco Polo fellowship). The variegated experimental approach, which consisted of two exposure experiments and in vitro tests, and the choice of selected tissues of M. galloprovincialis, the midgut gland for mitochondrial and microsomal preparations for subsequent laboratory assays and the gonads for the endocrine evaluations, aimed at drawing a clarifying pattern on the molecular mechanisms involved in organotin toxicity. TBT was promptly incorporated in midgut gland mitochondria of adult mussels exposed to 0.5 and 1.0 μg/L TBT, and partially degraded to DBT. TBT incorporation was accompanied by a decrease in the mitochondrial oligomycin-sensitive Mg-ATPase activity, while the coexistent oligomycin-insensitive fraction was unaffected. Mitochondrial fatty acids showed a clear rise in n-3 polyunsaturated fatty acids after 120 hr of TBT exposure, mainly referable to an increase in 22:6 level. TBT was also shown to inhibit the ATP hydrolytic activity of the mitochondrial F1FO complex in vitro and to promote an apparent loss of oligomycin sensitivity at higher than 1.0 μM concentration. The complex dose-dependent profile of the inhibition curve lead to the hypothesis of multiple TBT binding sites. At lower than 1.0 μM TBT concentrations the non competitive enzyme inhibition by TBT was ascribed to the non covalent binding of TBT to FO subunit. On the other hand the observed drop in oligomycin sensitivity at higher than 1.0 μM TBT could be related to the onset of covalent bonds involving thiolic groups on the enzyme structure, apparently reached only at high TBT levels. The mitochondrial respiratory complexes were in vitro affected by TBT, apart from the cytocrome c oxidase which was apparently refractory to the contaminant. The most striking inhibitory effect was shown on complex I, and ascribed to possible covalent bonds of TBT with –SH groups on the enzyme complexes. This mechanism, shouldered by the progressive decrease of free cystein residues in the presence of increasing TBT concentrations, suggests that the onset of covalent tin-sulphur bonds in distinct protein structures may constitute the molecular basis of widespread TBT effects on mitochondrial complexes. Energy production disturbances, in turn affecting energy consuming mechanisms, could be involved in other cellular changes. Mussels exposed to a wide range of TBT concentrations (20 - 200 and 2000 ng/L respectively) did not show any change in testosterone and estrogen levels in mature gonads. Most hormones were in the non-biologically active esterified form both in control and in TBT-treated mussels. Probably the endocrine status of sexually mature mussels could be refractory even to high TBT doses. In mussel digestive gland the high biological variability of microsomal 7-benzyloxy-4-trifluoromethylcoumarin-O-Debenzyloxylase (BFCOD) activity, taken as a measure of CYP3A-like efficiency, probably concealed any enzyme response to TBT exposure. On the other hand the TBT-driven enhancement of BFCOD activity in vitro was once again ascribed to covalent binding to thiol groups which, in this case, would stimulate the enzyme activity. In mussels from Barcelona harbour, a highly contaminated site, the enzyme showed a decreased affinity for the 7-benzyloxy-4-trifluoromethylcoumarin (BCF) substrate with respect to mussel sampled from Ebro Delta, a non-polluted marine site. Contaminant exposure may thus alter the kinetic features of enzymes involved in detoxification mechanisms. Contaminants and steroid hormones were clearly shown to mutually interact in the modulation of detoxification mechanisms. The xenoestrogen 17α-ethylenyl estradiol (EE2) displayed a non-competitive mixed inhibition of CYP3A-like activity by a preferential bond to the free enzyme both in Barcelona harbour and Ebro Delta mussels. The possible interaction with co-present contaminants in Barcelona harbour mussels apparently lessened the formation of the ternary complex enzyme-EE2-BCF. The whole of data confirms TBT as membrane toxicant in mussels as in other species and stresses TBT covalent binding to protein thiols as a widespread mechanism of membrane-bound-enzyme activity modulation by the contaminant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Proper hazard identification has become progressively more difficult to achieve, as witnessed by several major accidents that took place in Europe, such as the Ammonium Nitrate explosion at Toulouse (2001) and the vapour cloud explosion at Buncefield (2005), whose accident scenarios were not considered by their site safety case. Furthermore, the rapid renewal in the industrial technology has brought about the need to upgrade hazard identification methodologies. Accident scenarios of emerging technologies, which are not still properly identified, may remain unidentified until they take place for the first time. The consideration of atypical scenarios deviating from normal expectations of unwanted events or worst case reference scenarios is thus extremely challenging. A specific method named Dynamic Procedure for Atypical Scenarios Identification (DyPASI) was developed as a complementary tool to bow-tie identification techniques. The main aim of the methodology is to provide an easier but comprehensive hazard identification of the industrial process analysed, by systematizing information from early signals of risk related to past events, near misses and inherent studies. DyPASI was validated on the two examples of new and emerging technologies: Liquefied Natural Gas regasification and Carbon Capture and Storage. The study broadened the knowledge on the related emerging risks and, at the same time, demonstrated that DyPASI is a valuable tool to obtain a complete and updated overview of potential hazards. Moreover, in order to tackle underlying accident causes of atypical events, three methods for the development of early warning indicators were assessed: the Resilience-based Early Warning Indicator (REWI) method, the Dual Assurance method and the Emerging Risk Key Performance Indicator method. REWI was found to be the most complementary and effective of the three, demonstrating that its synergy with DyPASI would be an adequate strategy to improve hazard identification methodologies towards the capture of atypical accident scenarios.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il virus dell’Epatite E (HEV) e i calicivirus (norovirus e sapovirus) causano rispettivamente epatite acuta e gastroenterite. Questi virus sono considerati agenti eziologici emergenti rappresentando un problema di sanità pubblica e di sicurezza alimentare. Per HEV, è ormai confermata la trasmissione zoonotica, e il suino è considerato il principale serbatoio asintomatico. Norovirus e sapovirus infettano sia i bambini che gli adulti. Sebbene questi virus siano stati identificati anche negli animali, la possibile trasmissione zoonotica non è stata dimostrata in modo conclusivo. Il lavoro sperimentale condotto durante il Dottorato di Ricerca è stato focalizzato sullo studio degli aspetti biologici ed epidemiologici dell’infezioni causate da HEV e da calicivirus. Per la prima volta in Italia, i risultati ottenuti hanno dimostrato la presenza del virus HEV nei fegati di suini in fase di macellazione ed hanno confermato, attraverso la ricerca di anticorpi, un’elevata esposizione degli animali al virus. Inoltre, mediante la produzione di antigeni e reattivi immunologici, sono stati messi a punto test diagnostici per la ricerca di anticorpi contro HEV nel suino e nei cinghiali. Il lavoro svolto per la ricerca di calicivirus nel suino e nel bovino ha dimostrato la circolazione dei sapovirus in popolazioni di suini asintomatici e la presenza di norovirus nei vitelli affetti da diarrea acuta.Sono stati inoltre sviluppati reattivi immunologici, utilizzando proteine del capside di norovirus umano e bovino espresse con il sistema ricombinante baculovirus. Questi hanno permesso di evidenziare la presenza di anticorpi contro norovirus umano e bovino, in sieri di veterinari professionalmente esposti. Inoltre, sono stati utilizzati per sviluppare metodi per la concentrazione dei virus da matrici a bassa concentrazione.Infine, le VLP sono state utilizzate per valutare l’attivazione del sistema immunitario umano ex vivo. I risultati hanno dimostrato che le VLP di NoV stimolano il sistema immunitario attivando risposte di tipo Th1 e Th2 .

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, new tools in atmospheric pollutant sampling and analysis were applied in order to go deeper in source apportionment study. The project was developed mainly by the study of atmospheric emission sources in a suburban area influenced by a municipal solid waste incinerator (MSWI), a medium-sized coastal tourist town and a motorway. Two main research lines were followed. For what concerns the first line, the potentiality of the use of PM samplers coupled with a wind select sensor was assessed. Results showed that they may be a valid support in source apportionment studies. However, meteorological and territorial conditions could strongly affect the results. Moreover, new markers were investigated, particularly focusing on the processes of biomass burning. OC revealed a good biomass combustion process indicator, as well as all determined organic compounds. Among metals, lead and aluminium are well related to the biomass combustion. Surprisingly PM was not enriched of potassium during bonfire event. The second research line consists on the application of Positive Matrix factorization (PMF), a new statistical tool in data analysis. This new technique was applied to datasets which refer to different time resolution data. PMF application to atmospheric deposition fluxes identified six main sources affecting the area. The incinerator’s relative contribution seemed to be negligible. PMF analysis was then applied to PM2.5 collected with samplers coupled with a wind select sensor. The higher number of determined environmental indicators allowed to obtain more detailed results on the sources affecting the area. Vehicular traffic revealed the source of greatest concern for the study area. Also in this case, incinerator’s relative contribution seemed to be negligible. Finally, the application of PMF analysis to hourly aerosol data demonstrated that the higher the temporal resolution of the data was, the more the source profiles were close to the real one.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tractor rollover represent a primary cause of death or serious injury in agriculture and despite the mandatory Roll-Over Protective Structures (ROPS), that reduced the number of injuries, tractor accidents are still of great concern. Because of their versatility and wide use many studies on safety are concerned with the stability of tractors, but they often prefer controlled tests or laboratory tests. The evaluation of tractors working in field, instead, is a very complex issue because the rollover could be influenced by the interaction among operator, tractor and environment. Recent studies are oriented towards the evaluation of the actual working conditions developing prototypes for driver assistance and data acquisition. Currently these devices are produced and sold by manufacturers. A warning device was assessed in this study with the aim to evaluate its performance and to collect data on different variables influencing the dynamics of tractors in field by monitoring continuously the working conditions of tractors operating at the experimental farm of the Bologna University. The device consists of accelerometers, gyroscope, GSM/GPRS, GPS for geo-referencing and a transceiver for the automatic recognition of tractor-connected equipment. A microprocessor processes data and provides information, through a dedicated algorithm requiring data on the geometry of the tested tractor, on the level of risk for the operator in terms of probable loss of stability and suggests corrective measures to reduce the potential instability of the tractor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In chronic myeloid leukemia and Philadelphia-positive acute lymphoblastic leukemia patients resistant to tyrosine kinase inhibitors (TKIs), BCR-ABL kinase domain mutation status is an essential component of the therapeutic decision algorithm. The recent development of Ultra-Deep Sequencing approach (UDS) has opened the way to a more accurate characterization of the mutant clones surviving TKIs conjugating assay sensitivity and throughput. We decided to set-up and validated an UDS-based for BCR-ABL KD mutation screening in order to i) resolve qualitatively and quantitatively the complexity and the clonal structure of mutated populations surviving TKIs, ii) study the dynamic of expansion of mutated clones in relation to TKIs therapy, iii) assess whether UDS may allow more sensitive detection of emerging clones, harboring critical 2GTKIs-resistant mutations predicting for an impending relapse, earlier than SS. UDS was performed on a Roche GS Junior instrument, according to an amplicon sequencing design and protocol set up and validated in the framework of the IRON-II (Interlaboratory Robustness of Next-Generation Sequencing) International consortium.Samples from CML and Ph+ ALL patients who had developed resistance to one or multiple TKIs and collected at regular time-points during treatment were selected for this study. Our results indicate the technical feasibility, accuracy and robustness of our UDS-based BCR-ABL KD mutation screening approach. UDS was found to provide a more accurate picture of BCR-ABL KD mutation status, both in terms of presence/absence of mutations and in terms of clonal complexity and showed that BCR-ABL KD mutations detected by SS are only the “tip of iceberg”. In addition UDS may reliably pick 2GTKIs-resistant mutations earlier than SS in a significantly greater proportion of patients.The enhanced sensitivity as well as the possibility to identify low level mutations point the UDS-based approach as an ideal alternative to conventional sequencing for BCR-ABL KD mutation screening in TKIs-resistant Ph+ leukemia patients