6 resultados para computed tomography scan

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ultrasonography (US) is an essential imaging tool for identifying abnormalities of the liver parenchyma, biliary tract and vascular system. US has replaced radiography as the initial imaging procedure in screening for liver disease in small animals. There are few reports of the use of conventional and helical computed tomography (CT) to assess canine or feline parenchymal and neoplastic liver disease and biliary disorders. In human medicine the development of multidetector- row helical computed tomography (MDCT), with its superior spatial and temporal resolution, has resulted in improved detection and characterization of diffuse and focal liver lesions. The increased availability of MDCT in veterinary practice provides incentive to develop MDCT protocols for liver imaging in small animals. The purpose of this study is to assess the rule of MDCT in the characterization of hepatobiliary diseases in small animals; and to compare this method with conventional US. Candidates for this prospective study were 175 consecutive patients (dogs and cats) referred for evaluation of hepatobiliary disease. The patients underwent liver US and MDCT. Percutaneous needle biopsy was performed on all liver lesions or alterations encountered. As for gallbladder, histopatological evaluation was obtained from cholecystectomy specimens. Ultrasonographic findings in this study agreed well with those of previous reports. A protocol for dual-phase liver MDCT in small animals has been described. MDCT findings in parenchymal disorders of the liver, hepatic neoplasia and biliary disorders are here first described in dogs and cats and compared with the corresponding features in human medicine. The ability of MDCT in detection and characterization of hepatobiliary diseases in small animals is overall superior to conventional US. Ultrasonography and MDCT scanning, however, play complementary rules in the evaluation of these diseases. Many conditions have distinctive imaging features that may permit diagnosis. In most instances biopsy is required for definitive diagnosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multidetector row computed tomography over the last decade is commonly used in veterinary medicine. This new technology has an increased spatial and temporal resolution, could evaluate wider scanning range in shorter scanning time, providing an advanced imaging modality. Computed tomography angiographic studies are commonly used in veterinary medicine in order to evaluate vascular structures of the abdomen and the thorax. Pulmonary pathology in feline patients is a very common condition and usually is further evaluating with computed tomography. Up to date few references of the normal computed tomographic aspects of the feline thorax are reported. In this study a computed tomographic pulmonary angiography (CTPA) protocol is reported in normal cats and is compared with the up to date anatomical references. A CTPA protocol using a 64 MDCT in our study achieved high resolution images of the pulmonary arteries, pulmonary veins and bronchial lumen till the level of minor segmental branches. Feline pulmonary bronchial parenchyma demonstrates an architecture of mixed type with a monopedial model observed in the most anatomical parts and the dichotomic aspect is seen at the accessory lobe. The arterial and venous architecture is similar to the bronchial. Statistical analysis demonstrates the linear correlation of tracheal diameter to the felines weight. Vascular variations were noticed. The pulmonary venous system enters into the left atrium through three ostia (left cranial ostia: consisted of the anastomosis of the cranial and caudal portion of the left cranial pulmonary vein; right ostia: consisted of the anastomosis of the right cranial and middle pulmonary vein; and the caudal ostia: consisted of the anastomosis of the right and left caudal pulmonary vein). In conclusion CTPA is applicable in feline patients and provides an excellent imaging of the pulmonary arterial, venous and bronchial system till the level of minor segmental branches.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The main problem connected to cone beam computed tomography (CT) systems for industrial applications employing 450 kV X-ray tubes is the high amount of scattered radiation which is added to the primary radiation (signal). This stray radiation leads to a significant degradation of the image quality. A better understanding of the scattering and methods to reduce its effects are therefore necessary to improve the image quality. Several studies have been carried out in the medical field at lower energies, whereas studies in industrial CT, especially for energies up to 450 kV, are lacking. Moreover, the studies reported in literature do not consider the scattered radiation generated by the CT system structure and the walls of the X-ray room (environmental scatter). In order to investigate the scattering on CT projections a GEANT4-based Monte Carlo (MC) model was developed. The model, which has been validated against experimental data, has enabled the calculation of the scattering including the environmental scatter, the optimization of an anti-scatter grid suitable for the CT system, and the optimization of the hardware components of the CT system. The investigation of multiple scattering in the CT projections showed that its contribution is 2.3 times the one of primary radiation for certain objects. The results of the environmental scatter showed that it is the major component of the scattering for aluminum box objects of front size 70 x 70 mm2 and that it strongly depends on the thickness of the object and therefore on the projection. For that reason, its correction is one of the key factors for achieving high quality images. The anti-scatter grid optimized by means of the developed MC model was found to reduce the scatter-toprimary ratio in the reconstructed images by 20 %. The object and environmental scatter calculated by means of the simulation were used to improve the scatter correction algorithm which could be patented by Empa. The results showed that the cupping effect in the corrected image is strongly reduced. The developed CT simulation is a powerful tool to optimize the design of the CT system and to evaluate the contribution of the scattered radiation to the image. Besides, it has offered a basis for a new scatter correction approach by which it has been possible to achieve images with the same spatial resolution as state-of-the-art well collimated fan-beam CT with a gain in the reconstruction time of a factor 10. This result has a high economic impact in non-destructive testing and evaluation, and reverse engineering.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Il presente studio rappresenta la prima applicazione della tecnica CEUS in alcune delle più diffuse specie non convenzionali, nonché la prima nei rettili. In particolare è stata investigata la perfusione di fegato e milza in 10 conigli, 10 furetti e il fegato in 8 iguane. Per quanto riguarda i mammiferi, la tecnica è risultata di facile attuazione e i risultati ottenuti erano equiparabili a quelli documentati per i piccoli animali. Maggiore variabilità si è messa in evidenza a livello splenico in entrambe le specie e nel coniglio rispetto al furetto. Nelle iguane è stata necessaria una modifica del protocollo a seguito dei tempi più lunghi delle fasi di wash in e di wash out. Le curve ottenute erano caratterizzate da picchi più bassi e TTP più lunghi, con wash out incompleto anche dopo 10 minuti di indagine. Nelle iguane l’indagine del fegato è stata approfondita grazie all’esecuzione di TC dinamiche con MDC, studio pioneristico per quanto riguarda la medicina dei rettili. L’esecuzione è avvenuta senza problemi in anestesia generale. Diffusione del MDC e conseguenti variazione di HU a livello aortico e epatico sono state considerate contemporaneamente, con costruzione di curve HU-tempo piuttosto ripetibili, entrambe caratterizzate da un wash in rapido, un picco, particolarmente alto a livello aortico, e da una fase di wash out più lento, anche qui incompleto dopo i 600 secondi di indagine. Una certa variabilità è stata notata in tre individui, risultato attendibile conseguentemente alla forte dipendenza da fattori intriseci ed estrinseci del metabolismo e della funzionalità epatica dei rettili. L’intero protocollo è stato applicato in un furetto e due iguane patologiche, al fine di evidenziare le potenzialità cliniche delle tecniche. Sebbene il numero esiguo di casi non permetta di trarre conclusioni a questo riguardo, l’ultimo capitolo della tesi vuole essere uno spunto per studi futuri.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduzione: L’indicazione alla rivascolarizzazione carotidea è comunemente posta in base alla percentuale di stenosi, alla presenza di sintomi neurologici ed alle condizioni cliniche del paziente. Una placca ad elevato potenziale embolico viene definita “vulnerabile”; la sua caratterizzazione, tuttavia, non è universalmente accettata ai fini della rivascolarizzazione. Lo scopo dello studio è indagare il ruolo del mezzo di contrasto ecografico (CEUS) nell’identificazione della placca carotidea vulnerabile. Materiali e Metodi: I pazienti sottoposti a endoarterectomia carotidea, sono stati valutati mediante TC cerebrale preoperatoria e CEUS. Le microbolle di contrasto rilevate nella placca, indicative di neovascolarizzazione, sono state quantificate in dB-E ed istologicamente valutate per cinque caratteristiche: (densità dei microvasi, spessore del cappuccio fibroso, estensione delle calcificazioni, infiltrato infiammatorio e core lipidico) il valore da 1 a 5, ottenuto in cieco, indica in grado di vulnerabilità della placca. L'ANOVA test, il test di Fisher e t Student sono stati usati per correlare le caratteristiche dei pazienti ed istologiche col valore di dB-E. Risultati: Di 22 pazienti (range 2-7.8, media 4.85 ±1.9 SD) vi era un numero più alto di sintomatici (7.40 ± 0.5) rispetto agli asintomatici (3.5 ± 1.4) (p = 0.002). Un più alto valore di dB-E si associava con la presenza di un sottile cappuccino fibroso (<200 µm, 5.96±1.5 vs. 3 ± 1,p = 0.01) ed un maggiore infiltrato infiammatorio (3.2 ± 0.9 vs. 6.4 ± 1.2, p = 0.03). Placche con vulnerabilità 5 si associavano ad un valore più alto di dB-E rispetto alle placche con vulnerabilità 1 (7.6 ± 0.2 vs. 2.5 ± 0.6, rispettivamente, p=0.001). Preoperatoriamente, le lesioni emboliche ipsilaterali alla TC, correlavano con un più alto valore di dB-E (5.96±1.5 vs. 3.0±1.0, p=0.01). Conclusioni: Il valore di dB-E alla CEUS indica l’estensione della neovascolarizzazione della placca carotidea e può essere utilizzato come marker di vulnerabilità della placca.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective The objective of this study was to develop a clinical nomogram to predict gallium-68 prostate-specific membrane antigen positron emission tomography/computed tomography (68Ga-PSMA-11-PET/CT) positivity in different clinical settings of PSA failure. Materials and methods Seven hundred three (n = 703) prostate cancer (PCa) patients with confirmed PSA failure after radical therapy were enrolled. Patients were stratified according to different clinical settings (first-time biochemical recurrence [BCR]: group 1; BCR after salvage therapy: group 2; biochemical persistence after radical prostatectomy [BCP]: group 3; advanced stage PCa before second-line systemic therapies: group 4). First, we assessed 68Ga-PSMA-11-PET/CT positivity rate. Second, multivariable logistic regression analyses were used to determine predictors of positive scan. Third, regression-based coefficients were used to develop a nomogram predicting positive 68Ga-PSMA-11-PET/CT result and 200 bootstrap resamples were used for internal validation. Fourth, receiver operating characteristic (ROC) analysis was used to identify the most informative nomogram’s derived cut-off. Decision curve analysis (DCA) was implemented to quantify nomogram’s clinical benefit. Results 68Ga-PSMA-11-PET/CT overall positivity rate was 51.2%, while it was 40.3% in group 1, 54% in group 2, 60.5% in group 3, and 86.9% in group 4 (p < 0.001). At multivariable analyses, ISUP grade, PSA, PSA doubling time, and clinical setting were independent predictors of a positive scan (all p ≤ 0.04). A nomogram based on covariates included in the multivariate model demonstrated a bootstrap-corrected accuracy of 82%. The nomogram-derived best cut-off value was 40%. In DCA, the nomogram revealed clinical net benefit of > 10%. Conclusions This novel nomogram proved its good accuracy in predicting a positive scan, with values ≥ 40% providing the most informative cut-off in counselling patients to 68Ga-PSMA-11-PET/CT. This tool might be important as a guide to clinicians in the best use of PSMA-based PET imaging.