6 resultados para competitive replacement

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research is focused on the relationship between some Mg2+-dependent ATPase activities of plasma- and mitochondrial membranes from tissues of cultured marine bivalve molluscs and potentially stressful environmental conditions, such as the exposure to contaminants both of natural origin (ammonia nitrogen, the main contaminant of aquaculture plants) and of anthropic source (alkyltins). The two filter-feeding bivalve species selected colonize different habitats: the common mussel Mytilus galloprovincialis binds to hard substrates and the Philippine clam Tapes philippinarum burrows into sea bottom sandy beds. The choice of typical species of coastal waters, extremely suitable for environmental studies due to their features of poor motility, resistance to transport and great filtering efficiency, may constitute a model to evaluate responses to contaminants of membrane-bound enzyme activities involved in key biochemical mechanisms, namely cell ionic regulation and mitochondrial energy production. In vitro and in vitro approaches have been pursued. In vitro assays were carried out by adding the contaminants (NH4Cl and alkyltins) directly to the ATPase reaction media. In vivo experiments were carried out by exposing mussels to various tributyl tin (TBT) concentrations under controlled conditions in aquaria. ATPase activities were determined spectrophotometrically according to the principles of the method of Fiske and Subbarow (1925). The main results obtained are detailed below. In Tapes philippinarum the interaction of NH4 +, the main form of ammonia nitrogen at physiological and seawater pHs, with the Na,K-ATPase and the ouabaininsensitive Na-ATPase was investigated in vitro on gill and mantle microsomal membranes. The proven replacement by NH4 +of K+ in the activation of the Na,KATPase and of Na+ in the activation of the ouabain-insensitive ATPase displayed similar enzyme affinity for the substituted cation. on the one hand this finding may represent one of the possible mechanisms of ammonia toxicity and, on the other, it supports the hypothesis that NH4 + can be transported across the plasma membrane through the two ATPases. In this case both microsomal ATPases may be involved and co-operate, at least under peculiar circumstances, to nitrogen excretion and ammonia detoxification mechanisms in bivalve molluscs. The two ATPase activities stimulated by NH4 + maintained their typical response to the glycoside ouabain, specific inhibitor of the Na,K-ATPase, being the Na++ NH4 +-activated ATPase even more susceptive to the inhibitor and the ouabain-insensitive ATPase activity activated indifferently by Na+ or NH4 + unaffected by up to 10-2 M ouabain. In vitro assays were carried out to evaluate the response of the two Na-dependent ATPases to organotins in clams and mussels and to investigate the interaction of TBT with mussel mitochondrial oligomycin-sensitive Mg-ATPase. Since no literature data were available, the optimal assay conditions and oligomycin sensitivity of mussel mitochondrial MgATPase were determined. In T. philippinarum the ouabain-insensitive Na-ATPase was found to be refractory to TBT both in the gills and in the mantle, whereas the Na,K-ATPase was progressively inhibited by increasing TBT doses; the enzyme inhibition was more pronounced in the gills than in the mantle. In both tissues of M. galloprovincialis the Na,K-ATPase inhibition by alkyltins decreased in the order TBT>DBT(dibutyltin)>>MBT(monobutyltin)=TeET(tetraethyltin) (no effect). Mussel Na-ATPase confirmed its refractorimess to TBT and derivatives both in the gills and in the mantle. These results indicate that the Na,K-ATPase inhibition decreases as the number of alkyl chains bound to tin decreases; however a certain polarity of the organotin molecule is required to yield Na,K-ATPase inhibition, since no enzyme inhibition occurred in the presence of tetraalkyl-substituted derivatives such as TeET . Assays carried out in the presence of the dithioerythritol (DTE) pointed out that the sulphhydrylic agent is capable to prevent the Na,K-ATPase inhibition by TBT, thus suggesting that the inhibitor may link to -SH groups of the enzyme complex.. Finally, the different effect of alkyltins on the two Na-dependent ATPases may constitute a further tool to differentiate between the two enzyme activities. These results add to the wealth of literature data describing different responses of the two enzyme activities to endogenous and exogenous modulators . Mussel mitochondrial Mg-ATPase was also found to be in vitro inhibited by TBT both in the gills and in the mantle: the enzyme inhibition followed non competitive kinetics. The failed effect of DTE pointed out that in this case the interaction of TBT with the enzyme complex is probably different from that with the Na,K-ATPase. The results are consistent with literature data showing that alkyltin may interact with enzyme structures with different mechanisms. Mussel exposure to different TBT sublethal doses in aquaria was carried out for 120 hours. Two samplings (after 24 and 120 hrs) were performed in order to evaluate a short-term response of gill and mantle Na,K-ATPase, ouabain-insensitive Na-ATPase and Mg-ATPase activities. The in vivo response to the contaminants of the enzyme activities under study was shown to be partially different from that pointed out in the in vitro assays. Mitochondrial Mg-ATPase activity appeared to be activated in TBTexposed mussels with respect to control ones, thus confirming the complexity of evaluating in vivo responses of the enzyme activities to contaminants, due to possible interactions of toxicants with molluscan metabolism. Concluding, the whole of data point out that microsomal and mitochondrial ATPase activities of bivalve molluscs are generally responsive to environmental contaminants and suggest that in some cases membrane-bound enzyme activities may represent the molecular target of their toxicity. Since the Na,K-ATPase, the Na-ATPase and the Mg-ATPase activities are poorly studied in marine bivalves, this research may contribute to enlarge knowledge in this quite unexplored field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the thesis I exploit an empirical analysis on firm'’s productivity. I relate the efficiency at plant level with the input market features and I suggest an estimation technique for production function that takes into account firm'’s liquidity constraints. The main results are three. When I consider services as inputs for manufacturing firm’'s production process, I find that more competition in service sector affects positively plant’s productivity and export decision. Secondly liquidity constraints are important for the calculation of firm'’s productivity because they are a second source of firm's heterogeneity. Third liquidity constraints are important for firm'’s internationalization

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Italia, il contesto legislativo e l’ambiente competitivo dei Confidi è profondamente mutato negli ultimi anni a seguito dell’emanazione di due nuove normative: la “Legge Quadro” sui Confidi e la nuova regolamentazione del capitale di vigilanza nelle banche (c.d. "Basilea 2"). la Legge Quadro impone ai Confidi di adottare uno dei seguenti status societari: i) ente iscritto all’albo di cui all’art. 106 del Testo Unico Bancario (TUB); ii) ente iscritto all’albo di cui all’art. 107 del Testo Unico Bancario; iii) banca cooperativa di garanzia collettiva dei fidi. Fermi restando i requisiti soggettivi sui garanti ammessi da Basilea 2, la modalità tecnica finora utilizzata dai Confidi non risponde ai requisiti oggettivi. Il pensiero strategico si enuclea nelle seguenti domande: A) qual è la missione del Confidi (perché esistono i Confidi)? B) Quali prodotti e servizi dovrebbero offrire per raggiungere la loro missione? C) Quale modello organizzativo e di governance si conforma meglio per l'offerta dei prodotti e servizi individuati come necessari per il raggiungimento della missione? Le riflessioni condotte nell’ambito di un quadro di riferimento delineato dal ruolo delle garanzie nel mercato del credito bancario, dalle “Nuove disposizioni di vigilanza prudenziale per le banche”, dalla “Legge Quadro” sui e, infine, dall’assetto istituzionale ed operativo dei Confidi si riassumono nelle seguenti deduzioni: Proposizione I: segmentare la domanda prima di adeguare l’offerta; Proposizione II: le operazioni tranched cover sono un'alternativa relativamente efficiente per l'operatività dei Confidi, anche per quelli non vigilati; Proposizione III: solo i Confidi‐banca hanno la necessità di dotarsi di un rating esterno; Proposizione IV: le banche sono nuovi Clienti dei Confidi: offrire servizi di outsourcing (remunerati), ma non impieghi di capitale; Proposizione V: le aggregazioni inter settoriali nel medesimo territorio sono da preferirsi alle aggregazioni inter territoriali fra Confidi del medesimo settore. Alle future ricerche è affidato il compito di verificare: quali opzioni strategiche nel concreato siano state applicate; quali siano state le determinati di tali scelte; il grado di soddisfacimento dei bisogni degli stakeholder dei Confidi; misurare i benefici conseguiti nell'efficienza allocativa del credito.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is dedicated to the analysis of non-linear pricing in oligopoly. Non-linear pricing is a fairly predominant practice in most real markets, mostly characterized by some amount of competition. The sophistication of pricing practices has increased in the latest decades due to the technological advances that have allowed companies to gather more and more data on consumers preferences. The first essay of the thesis highlights the main characteristics of oligopolistic non-linear pricing. Non-linear pricing is a special case of price discrimination. The theory of price discrimination has to be modified in presence of oligopoly: in particular, a crucial role is played by the competitive externality that implies that product differentiation is closely related to the possibility of discriminating. The essay reviews the theory of competitive non-linear pricing by starting from its foundations, mechanism design under common agency. The different approaches to model non-linear pricing are then reviewed. In particular, the difference between price and quantity competition is highlighted. Finally, the close link between non-linear pricing and the recent developments in the theory of vertical differentiation is explored. The second essay shows how the effects of non-linear pricing are determined by the relationship between the demand and the technological structure of the market. The chapter focuses on a model in which firms supply a homogeneous product in two different sizes. Information about consumers' reservation prices is incomplete and the production technology is characterized by size economies. The model provides insights on the size of the products that one finds in the market. Four equilibrium regions are identified depending on the relative intensity of size economies with respect to consumers' evaluation of the good. Regions for which the product is supplied in a single unit or in several different sizes or in only a very large one. Both the private and social desirability of non-linear pricing varies across different equilibrium regions. The third essay considers the broadband internet market. Non discriminatory issues seem the core of the recent debate on the opportunity or not of regulating the internet. One of the main questions posed is whether the telecom companies, owning the networks constituting the internet, should be allowed to offer quality-contingent contracts to content providers. The aim of this essay is to analyze the issue through a stylized two-sided market model of the web that highlights the effects of such a discrimination over quality, prices and participation to the internet of providers and final users. An overall welfare comparison is proposed, concluding that the final effects of regulation crucially depend on both the technology and preferences of agents.