3 resultados para bioelectrical impedance analysis

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phase 1: To validate Near-Infrared Reflectance Analysis (NIRA) as a fast, reliable and suitable method for routine evaluation of human milk’s nitrogen and fat content. Phase 2: To determine whether fat content, protein content and osmolality of HM before and after fortification may affect gastroesophageal reflux (GER) in symptomatic preterm infants. Patients and Methods: Phase 1: 124 samples of expressed human milk (55 from preterm mothers and 69 from term mothers) were used to validate NIRA against traditional methods (Gerber method for fat and Kjeldhal method for nitrogen). Phase 2: GER was evaluated in 17 symptomatic preterm newborns fed naïve and fortified HM by combined pH/intraluminal-impedance monitoring (pH-MII). HM fat and protein content was analysed by a Near-Infrared-Reflectance-Analysis (NIRA). HM osmolality was tested before and after fortification. GER indexes measured before and after fortification were compared, and were also related with HM fat and protein content and osmolality before and after fortification. Results: Phase 1: · A strong agreement was found between traditional methods’ and NIRA’s results (expressed as g/100 g of milk), both for fat and nitrogen content in term (mean fat content: NIRA=2.76; Gerber=2.76; mean nitrogen content: NIRA=1.88; Kjeldhal =1.92) and preterm (mean fat content: NIRA=3.56; Kjeldhal=3.52; mean nitrogen content: NIRA=1.91; Kjeldhal =1.89) mother’s milk. · Nitrogen content of the milk samples, measured by NIRA, ranged from 1.18 to 2.71 g/100 g of milk in preterm milk and from 1.48 to 2.47 in term milk; fat content ranged from 1.27 to 6.23 g/100 g of milk in preterm milk and from 1.01 to 6.01 g/100 g of milk in term milk. Phase 2: · An inverse correlation was found between naïve HM protein content and acid reflux index (RIpH: p=0.041, rho=-0.501). · After fortification, osmolality often exceeded the values recommended for infant feeds; furthermore, a statistically significant (p<.05) increase in non acid reflux indexes was observed. Conclusions: NIRA can be used as a fast, reliable and suitable tool for routine monitoring of macronutrient content of human milk. Protein content of naïve HM may influence acid GER in preterm infants. A standard fortification of HM may worsen non acid GER indexes and, due to the extreme variability in HM composition, may overcome both recommended protein intake and HM osmolality. Thus, an individualized fortification, based on the analysis of the composition of naïve HM, could optimize both nutrient intake and feeding tolerance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monitoring foetal health is a very important task in clinical practice to appropriately plan pregnancy management and delivery. In the third trimester of pregnancy, ultrasound cardiotocography is the most employed diagnostic technique: foetal heart rate and uterine contractions signals are simultaneously recorded and analysed in order to ascertain foetal health. Because ultrasound cardiotocography interpretation still lacks of complete reliability, new parameters and methods of interpretation, or alternative methodologies, are necessary to further support physicians’ decisions. To this aim, in this thesis, foetal phonocardiography and electrocardiography are considered as different techniques. Further, variability of foetal heart rate is thoroughly studied. Frequency components and their modifications can be analysed by applying a time-frequency approach, for a distinct understanding of the spectral components and their change over time related to foetal reactions to internal and external stimuli (such as uterine contractions). Such modifications of the power spectrum can be a sign of autonomic nervous system reactions and therefore represent additional, objective information about foetal reactivity and health. However, some limits of ultrasonic cardiotocography still remain, such as in long-term foetal surveillance, which is often recommendable mainly in risky pregnancies. In these cases, the fully non-invasive acoustic recording, foetal phonocardiography, through maternal abdomen, represents a valuable alternative to the ultrasonic cardiotocography. Unfortunately, the so recorded foetal heart sound signal is heavily loaded by noise, thus the determination of the foetal heart rate raises serious signal processing issues. A new algorithm for foetal heart rate estimation from foetal phonocardiographic recordings is presented in this thesis. Different filtering and enhancement techniques, to enhance the first foetal heart sounds, were applied, so that different signal processing techniques were implemented, evaluated and compared, by identifying the strategy characterized on average by the best results. In particular, phonocardiographic signals were recorded simultaneously to ultrasonic cardiotocographic signals in order to compare the two foetal heart rate series (the one estimated by the developed algorithm and the other provided by cardiotocographic device). The algorithm performances were tested on phonocardiographic signals recorded on pregnant women, showing reliable foetal heart rate signals, very close to the ultrasound cardiotocographic recordings, considered as reference. The algorithm was also tested by using a foetal phonocardiographic recording simulator developed and presented in this research thesis. The target was to provide a software for simulating recordings relative to different foetal conditions and recordings situations and to use it as a test tool for comparing and assessing different foetal heart rate extraction algorithms. Since there are few studies about foetal heart sounds time characteristics and frequency content and the available literature is poor and not rigorous in this area, a data collection pilot study was also conducted with the purpose of specifically characterising both foetal and maternal heart sounds. Finally, in this thesis, the use of foetal phonocardiographic and electrocardiographic methodology and their combination, are presented in order to detect foetal heart rate and other functioning anomalies. The developed methodologies, suitable for longer-term assessment, were able to detect heart beat events correctly, such as first and second heart sounds and QRS waves. The detection of such events provides reliable measures of foetal heart rate, potentially information about measurement of the systolic time intervals and foetus circulatory impedance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Analysis of the peak-to-peak output current ripple amplitude for multiphase and multilevel inverters is presented in this PhD thesis. The current ripple is calculated on the basis of the alternating voltage component, and peak-to-peak value is defined by the current slopes and application times of the voltage levels in a switching period. Detailed analytical expressions of peak-to-peak current ripple distribution over a fundamental period are given as function of the modulation index. For all the cases, reference is made to centered and symmetrical switching patterns, generated either by carrier-based or space vector PWM. Starting from the definition and the analysis of the output current ripple in three-phase two-level inverters, the theoretical developments have been extended to the case of multiphase inverters, with emphasis on the five- and seven-phase inverters. The instantaneous current ripple is introduced for a generic balanced multiphase loads consisting of series RL impedance and ac back emf (RLE). Simplified and effective expressions to account for the maximum of the output current ripple have been defined. The peak-to-peak current ripple diagrams are presented and discussed. The analysis of the output current ripple has been extended also to multilevel inverters, specifically three-phase three-level inverters. Also in this case, the current ripple analysis is carried out for a balanced three-phase system consisting of series RL impedance and ac back emf (RLE), representing both motor loads and grid-connected applications. The peak-to-peak current ripple diagrams are presented and discussed. In addition, simulation and experimental results are carried out to prove the validity of the analytical developments in all the cases. The cases with different phase numbers and with different number of levels are compared among them, and some useful conclusions have been pointed out. Furthermore, some application examples are given.