5 resultados para VERTEBRATE LIMB
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.
Resumo:
The ‘Continental Intercalaire’ deposits of the Tataouine basin of southern Tunisia preserve one of the most diverse Cretaceous vertebrate fauna from Africa. This research project focuses on a detailed revision of the stratigraphic distribution of mid-Cretaceous fossil beds in the Tataouine Basin and includes the description of four, newly discovered vertebrate tracksites. In the Tataouine region, macro- and microvertebrate remains are recovered from three stratigraphic intervals: the lower Douiret Formation (Barremian), the Chenini (rare) and Oum ed Diab members of the Aïn El Guettar Formation (Albian). A detailed, basin-scale revision of the stratigraphic occurrence of fossil-bearing strata indicates 1. lateral facies variability within the context of a low gradient, circalittoral to coastal-plain environment; 2. multiple and diachronous fossil beds which include elasmobranchs, actinopterygians, sarcopterygians, turtles, crocodyliforms, pterosaurs, and non-avian dinosaurs remains. Four vertebrate tracksites have been discovered in the study area: 1. the Middle Jurassic Beni Ghedir site which preserves approximately 130 tridactyl footprints distributed over an area of 200 square meters, representing the oldest evidence of a dinosaur fauna in Tunisia; 2. the late Albian Chenini tracksite, which includes poorly preserved crocodilian tracks and the dinosaur ichnospecies Apulosauripus federicianus; 3. the Cenomanian Ksar Ayaat locality, where footprints assigned to a pleurodiran turtle are exposed, and 4. the upper Cenomanian Jebel Boulouha site which presents almost 100 well-preserved tridactyl tracks referred to small-sized theropods, fossil bird tracks - ichnogenus Koreanaorins – and tracks referred to a mammalian trackmaker, representing the first report of fossil bird and mammal from the Cretaceous of continental Africa and Tunisia respectively. In addition, data collected from the Tunisian tracksites have been compared with coeval tracksites in Italy and Croatia, showing analogies in morphology and paleoenvironment of dinosaur ichnoassociations, supporting the already hypothesized subaerial connection between these areas during the mid-Cretaceous.
Resumo:
The primary aim of the research activity presented in this PhD thesis was the development of an innovative hardware and software solution for creating a unique tool for kinematics and electromyographic analysis of the human body in an ecological setting. For this purpose, innovative algorithms have been proposed regarding different aspects of inertial and magnetic data elaboration: magnetometer calibration and magnetic field mapping (Chapter 2), data calibration (Chapter 3) and sensor-fusion algorithm. Topics that may conflict with the confidentiality agreement between University of Bologna and NCS Lab will not be covered in this thesis. After developing and testing the wireless platform, research activities were focused on its clinical validation. The first clinical study aimed to evaluate the intra and interobserver reproducibility in order to evaluate three-dimensional humero-scapulo-thoracic kinematics in an outpatient setting (Chapter 4). A second study aimed to evaluate the effect of Latissimus Dorsi Tendon Transfer on shoulder kinematics and Latissimus Dorsi activation in humerus intra - extra rotations (Chapter 5). Results from both clinical studies have demonstrated the ability of the developed platform to enter into daily clinical practice, providing useful information for patients' rehabilitation.
Resumo:
The limb amputation is one of the oldest surgical procedures performed and it still represents an event that drastically changes the life of an individual. Despite the technological progress, the difficulties related to the realization and daily use of the socket remain very common. Among the different technologies adopted in the prosthetic field, this project focused on the osseointegration technique. This technique consists in implanting a stem within the medullary canal of the amputated skeletal segment that extends outside the amputation stump with a prosthesis, later connected to the metal extension. The objective of this PhD project is to treat and to evaluate selected patients with osseointegrated prosthetic implants for the treatment of lower limb amputations. Patients are recruited at the Rizzoli Orthopaedic Institute and at the Prosthesis - INAIL center of Vigorso (Budrio) during outpatient visits, while the surgical procedure is performed by the same expert surgeon in the II Orthopaedic and Traumatology Clinic of the Rizzoli Orthopaedic Institute. The project is still ongoing, to date three patients had completed both procedures, but due to various personal problems, just one of them is included in the analysis. This patient increased his percentage of prosthesis use and the level of mobility with an overall improvement of quality of live after the procedure. The osseointegration technique represents a promising alternative method of treatment for amputees who are not satisfied with their socket prosthesis. In the coming years it will continue the collection of clinical, radiographic and kinematic data of subjects undergoing this procedure in order to perform a long-term monitoring of both clinical outcomes and quality of life.