9 resultados para Transcutaneous Ultrasonography
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
Ultrasonography (US) is an essential imaging tool for identifying abnormalities of the liver parenchyma, biliary tract and vascular system. US has replaced radiography as the initial imaging procedure in screening for liver disease in small animals. There are few reports of the use of conventional and helical computed tomography (CT) to assess canine or feline parenchymal and neoplastic liver disease and biliary disorders. In human medicine the development of multidetector- row helical computed tomography (MDCT), with its superior spatial and temporal resolution, has resulted in improved detection and characterization of diffuse and focal liver lesions. The increased availability of MDCT in veterinary practice provides incentive to develop MDCT protocols for liver imaging in small animals. The purpose of this study is to assess the rule of MDCT in the characterization of hepatobiliary diseases in small animals; and to compare this method with conventional US. Candidates for this prospective study were 175 consecutive patients (dogs and cats) referred for evaluation of hepatobiliary disease. The patients underwent liver US and MDCT. Percutaneous needle biopsy was performed on all liver lesions or alterations encountered. As for gallbladder, histopatological evaluation was obtained from cholecystectomy specimens. Ultrasonographic findings in this study agreed well with those of previous reports. A protocol for dual-phase liver MDCT in small animals has been described. MDCT findings in parenchymal disorders of the liver, hepatic neoplasia and biliary disorders are here first described in dogs and cats and compared with the corresponding features in human medicine. The ability of MDCT in detection and characterization of hepatobiliary diseases in small animals is overall superior to conventional US. Ultrasonography and MDCT scanning, however, play complementary rules in the evaluation of these diseases. Many conditions have distinctive imaging features that may permit diagnosis. In most instances biopsy is required for definitive diagnosis.
Resumo:
INTRODUCTION – In human medicine, diabetes mellitus (DM), hypertension, proteinuria and nephropathy are often associated although it is still not clear whether hypertension is the consequence or the cause of nephropathy and albuminuria. Microalbuminuria, in humans, is an early and sensitive marker which permits timely and effective therapy in the early phase of renal damage. Conversely, in dogs, these relationships were not fully investigated, even though hypertension has been associated with many diseases (Bodey and Michell, 1996). In a previous study, 20% of diabetic dogs were found proteinuric based on a U:P/C > 1 and 46% were hypertensive; this latter finding is similar to the prevalence of hypertension in diabetic people (40-80%) (Struble et al., 1998). In the same canine study, hypertension was also positively correlated with the duration of the disease, as is the case in human beings. Hypertension was also found to be a common complication of hypercortisolism (HC) in dogs, with a prevalence which varies from 50 (Goy-Thollot et al., 2002) to 80% (Danese and Aron, 1994).The aim of our study was to evaluate the urinary albumin to creatinine ratio (U:A/C) in dogs affected by Diabetes Mellitus and HC in order to ascertain if, as in human beings, it could represent an early and more sensitive marker of renal damage than U:P/C. Furthermore, the relationship between proteinuria and hypertension in DM and HC was also investigated. MATERIALS AND METHODS – Twenty dogs with DM, 14 with HC and 21 healthy dogs (control group) were included in the prospective case-control study. Inclusion criteria were hyperglycaemia, glicosuria and serum fructosamine above the reference range for DM dogs and a positive ACTH stimulation test and/or low-dose dexamethasone test and consistent findings of HC on abdominal ultrasonography in HC dogs. Dogs were excluded if affected by urinary tract infections and if the serum creatinine or urea values were above the reference range. At the moment of inclusion, an appropriate therapy had already been instituted less than 1 month earlier in 12 diabetic dogs. The control dogs were considered healthy based on clinical exam and clinicopathological findings. All dogs underwent urine sample collection by cystocentesis and systemic blood pressure measurement by means of either an oscillometric device (BP-88 Next, Colin Corporation, Japan) or by Doppler ultrasonic traducer (Minidop ES-100VX, Hadeco, Japan). The choice of method depended on the dog’s body weight: Doppler ultrasonography was employed in dogs < 20 kg of body weight and the oscillometric method in the other subjects. Dogs were considered hypertensive whenever systemic blood pressure was found ≥ 160 mmHg. The urine was assayed for U:P/C and U:A/C (Gentilini et al., 2005). The data between groups were compared using the Mann-Whitney U test. The reference ranges for U:P/C and U:A/C had already been established by our laboratory as 0.6 and 0.05, respectively. U:P/C and U:A/C findings were correlated to systemic blood pressure and Spearman R correlation coefficients were calculated. In all cases, p < 0.05 was considered statistically significant. RESULTS – The mean ± sd urinary albumin concentration in the three groups was 1.79 mg/dl ± 2.18; 20.02 mg/dl ± 43.25; 52.02 mg/dl ± 98.27, in healthy, diabetic and hypercortisolemic dogs, respectively. The urine albumin concentration differed significantly between healthy and diabetic dogs (p = 0.008) and between healthy and HC dogs (p = 0.011). U:A/C values ranged from 0.00 to 0.34 (mean ± sd 0.02 ± 0.07), 0.00 to 6.72 (mean ± sd 0.62 ± 1.52) and 0.00 to 5.52 (mean ± sd 1.27 ± 1.70) in the control, DM and HC groups, respectively; U:P/C values ranged from 0.1 to 0.6 (mean ± sd 0.17 ± 0.15) 0.1 to 6.6 (mean ± sd 0.93 ± 1.15) and 0.2 to 7.1 (mean ± sd 1.90 ± 2.11) in the control, DM and HC groups, respectively. In diabetic dogs, U:A/C was above the reference range in 11 out of 20 dogs (55%). Among these, 5/20 (25%) showed an increase only in the U:A/C ratio while, in 6/20 (30%), both the U:P/C and the U:A/C were abnormal. Among the latter, 4 dogs had already undergone therapy. In subjects affected with HC, U:P/C and U:A/C were both increased in 10/14 (71%) while in 2/14 (14%) only U:A/C was above the reference range. Overall, by comparing U:P/C and U:A/C in the various groups, a significant increase in protein excretion in disease-affected animals compared to healthy dogs was found. Blood pressure (BP) in diabetic subjects ranged from 88 to 203 mmHg (mean ± sd 143 ± 33 mmHg) and 7/20 (35%) dogs were found to be hypertensive. In HC dogs, BP ranged from 116 to 200 mmHg (mean ± sd 167 ± 26 mmHg) and 9/14 (64%) dogs were hypertensive. Blood pressure and proteinuria were not significantly correlated. Furthermore, in the DM group, U:P/C and U:A/C were both increased in 3 hypertensive dogs and 2 normotensive dogs while the only increase of U:A/C was observed in 2 hypertensive and 3 normotensive dogs. In the HC group, the U:P/C and the U:A/C were both increased in 6 hypertensive and 2 normotensive dogs; the U:A/C was the sole increased parameter in 1 hypertensive dog and in 1 dog with normal pressure. DISCUSSION AND CONCLUSION- The findings of this study suggest that, in dogs affected by DM and HC, an increase in U:P/C, U:A/C and systemic hypertension is frequently present. Remarkably, some dogs affected by both DM and HC showed an U:A/C but not U:P/C above the reference range. In diabetic dogs, albuminuria was observed in 25% of the subjects, suggesting the possibility that this parameter could be employed for detecting renal damage at an early phase when common semiquantiative tests and even U:P/C fall inside the reference range. In HC dogs, a higher number of subjects with overt proteinuria was found while only 14% presented an increase only in the U:A/C. This fact, associated with a greater number of hypertensive dogs having HC rather than DM, could suggest a greater influence on renal function by the mechanisms involved in hypertension secondary to hypercortisolemia. Furthermore, it is possible that, in HC dogs, the diagnosis was more delayed than in DM dogs. However, the lack of a statistically significant correlation between hypertension and increased protein excretion as well as the apparently random distribution of proteinuric subjects in normotensive and hypertensive cases, imply that other factors besides hypertension are involved in causing proteinuria. Longitudinal studies are needed to further investigate the relationship between hypertension and proteinuria.
Resumo:
Evaluation of carotid artery intima-media thickness in patients affected by psoriasis Psoriasis is associated with an increased risk of atherosclerosis. This study compared subclinical atherosclerosis, evaluating intima-media thickness the of the carotid in psoriasis vulgaris patients and healthy controls using high-resolution ultrasonography and the correlation of this parameter with other cardiovascular risk factors, like insulin resistance and dyslipidemia, METHODS: We will study 40 psoriasis patients, asymptomatic for cardiovascular diseases, and 40 healthy controls matched for age and sex. Intima-media thickness of the common carotid arteries will be measured ultrasonographically. Diabetes mellitus, hypertension, renal failure, a history of cardiovascular or cerebrovascular disease will be exclusion criteria. Subjects who are receiving lipid-lowering therapy, antihypertensive or anti-aggregant drugs, nitrates or long-term systemic steroids will be also excluded. Objective of this study is the evaluation of carotid artery intima-media thickness and its correlation with other blood cardiovascular risk factors in patients affected by psoriasis but asinptomatic for coronary comparing this data with the healthy control subjects. Considering that the presence of psoriasis is an independent risk factor for subclinical atherosclerosis, we want to consider this method of evaluation of cardiovascular risk and to control this risk to prevent IMA.
Resumo:
Cerebellar malformation are increasingly diagnosed in utero. To assess the effectiveness of ultrasound and fetal magnetic resonance in the antenatal prediction of long term neurodevelopmental delay. STUDY DESIGN: We collected 105 cases of cerebellum malformation in the period 2000-2010 in Bologna and Bari University. Classification included cystic anomalies of posterior fossa and cerebellar hypoplasia. RESULTS: The greater group included Blake’s pouch cysts and mega cisterna magna cases (58/105). These cases seemed to have a good prognosis with a good outcome both in association with other anomalies and isolated. In cases of Dandy Walker malformation, vermis hypoplasia and cerebellum hypoplasia there were few survivors, so it was so difficult to outline some conclusion for child outcome. Despite great neuroimaging advances, in our study, ultrasound and MR reached a similar sensitivity (62-63%) for the diagnosis of posterior fossa anomalies, but the number of MR was lower compared with ultrasonography. CONCLUSION: Ultrasonography remains the screening method of choice for evaluation of cerebellum anatomy but probably MR imaging can improve some details expecially in the third trimester. Despite the data on Dandy Walker, vermis hypoplasia and cerebellum hypoplasia were conflicting and uncertain, for Blake and mega cisterna magna we can considered a rather good outcome.
Resumo:
Scopo dello studio: Stabilire se cambiamenti della perfusione di una lesione target di epatocarcinoma (HCC), valutati quantitativamente mediante ecografia con contrasto (CE-US) alla settimana 2 e 4 di terapia con sorafenib, possono predire la progressione di malattia alla settimana 8, valutata con la tomografia computerizzata o la risonanza magnetica con mezzo di contrasto (TC-RM) usando i criteri RECIST/RECIST modificati (response evaluation criteria in solid tumors). Pazienti e metodi: Il comitato etico ha approvato lo studio ed i pazienti hanno fornito un consenso informato scritto prima dell’arruolamento. Lo studio è stato effettuato su un campione di soggetti con epatocarcinoma avanzato o non suscettibile di trattamento curativo, in monoterapia con sorafenib. La valutazione della risposta tumorale è stata effettuata con TC o RM a 2 mesi usando i criteri RECIST/RECIST modificati. La CE-US è stata effettuata entro 1 settimana prima dell’inizio del trattamento con sorafenib e durante la terapia alla settimana 2, 4, 8, 16 e 32. I parametri quantitativi funzionali sono stati ottenuti impiegando un software dedicato. I cambiamenti dei valori dei parametri suddetti tra il tempo zero ed i punti temporali successivi sono stati confrontati con la risposta tumorale basata sui criteri RECIST/RECIST modificati. Risultati: La riduzione dei valori dei parametri relativi alla perfusione tumorale, in particolare di WiAUC e PE (parametri correlati con il volume ematico), al T2/T4 (settimana 2, 4), predice la risposta tumorale a 2 mesi, valutata secondo i criteri RECIST e RECIST modificati, risultata indicativa di malattia stabile (responders). Conclusione: L’ecografia con contrasto può essere impiegata per quantificare i cambiamenti della vascolarizzazione tumorale già alla settimana 2, 4 dopo la somministrazione di sorafenib nei pazienti con HCC. Questi precoci cambiamenti della perfusione tumorale possono essere predittivi della risposta tumorale a 2 mesi e possono avere un potenziale nella valutazione precoce dell'efficacia della terapia antiangiogenica nell’epatocarcinoma.
Resumo:
Lung ultrasound use is increasing in respiratory medicine thanks to its development in the latest years. Actually it allows to study diseases of the chest wall (traumas, infections, neoplasms), diaphragm (paralysis, ipokinesis), pleura (effusions, pneumothorax, thickenings, neoplasms) and lung parenchyma (consolidations, interstitial syndromes, peripheral lesions). One of the most useful application of chest ultrasound is the evaluation of effusions. However, no standardized approach for ultrasound-guided thoracenthesis is available. Our study showed that our usual ultrasonographic landmark (“V-point”) could be a standard site to perform thoracenthesis: in 45 thoracenthesis no pneumothorax occurred, drainage was always successful at first attempt. Values of maximum thickness at V-point and drained fluid volume showed a significative correlation. Proteins concentration of ultrasound patterns of effusions (anechoic, ipoechoic, moving echoic spots, dense moving spots, hyperechoic) were compared to those of the macroscopic features of fluids showing connection between light-yellow fluid and echoic moving spots pattern and between ipoechoic/dense moving spots and cloudy-yellow/serum-haematic fluids. These observations suggest that ultrasound could predict chemical-physical features of effusions. Lung ultrasound provides useful information about many disease of the lung, but actually there is not useful in obstructive bronchial diseases. Analysing diaphragmatic kinetics using M-mode through transhepatic scan we described a similarity between diaphragm excursion during an expiratory forced maneuver and the volume/time curve of spirometry. This allowed us to identify the M-mode Index of Obstruction (MIO), an ultrasound-analogue of FEV1/VC. We observed MIO values of normal subjects (9) and obstructed patients (9) comparing the two groups. FEV1/VC and MIO showed a significant correlation suggesting that MIO may be affected by airways obstruction; MIO values were significatively different between normal and obstructed so that it could identify an obstructive syndrome. The data show that it is possible to suspect the presence of obstructive syndrome of the airways using ultrasonography of the diaphragm.
Resumo:
Obiettivi. L’ecografia con mezzo di contrasto (CEUS) può fornire informazioni sulla microvascolarizzazione della parete intestinale nella malattia di Crohn. L’infiammazione della parete intestinale non sembra essere correlata alla quantità di parete vascolarizzata (studi di pattern di vascolarizzazione, SVP) ma all’intensità del flusso di parete in un determinato periodo di tempo (studi di intensità-tempo, SIT). Scopo dello studio è valutare se gli studi SVP e/o SIT mediante CEUS siano in grado di mostrare il reale grado d’infiammazione della parete vascolare e se possano predire l’attività di malattia a 3 mesi. Materiali e metodi: 30 pazienti con malattia di Crohn venivano sottoposti a SVP e SIT mediante CEUS e venivano rivisti dopo 3 mesi. L’eCografia era eseguita con uno strumento dedicato con un software particolare per il calcolo delle curve intensità-tempo e con l’ausilio di un mezzo di contrasto (Sonovue). L’analisi quantitativa consisteva nella misura dell’area sotto la curva (AUC) (con cut-off tra malattia attiva e inattiva di 15) e di un intensità media (IM) con un cut-off di 10. Tutti gli esami venivano registrati e analizzati in modo digitale. Risultati: A T0: CDAI era inferiore a 150 in 22 pazienti e superiore a 150 in 8 pazienti; a T3: CDAI era inferiore a 150 in 19 pazienti e superiore a 150 in 11 pazienti. A T0 sia la CEUS SPV che la SIT evidenziavano bassa specificità, accuratezza diagnostica e valore predittivo negativo; a T3 la CEUS SVP mostrava bassa sensibilità e accuratezza diagnostica rispetto alla SIT che era in grado, in tutti i casi tranne uno, di predire l’attività clinica di malattia a tre mesi. Conclusioni: in questo studio, la CEUS-SIT ha mostrato buona accuratezza diagnostica nel predire l’attività clinica di malattia nel follow-up a breve termine di pazienti con malattia di Crohn.
Resumo:
L’ecografia del tratto gastroenterico è una delle metodiche d’elezione nella valutazione diagnostica delle patologie gastrointestinali nel gatto. In questa tesi dottorale sono presentati i risultati di tre studi in cui l’ecografia convenzionale e con mezzo di contrasto è stata impiegata in gatti sani o con patologie gastroenteriche. Lo scopo del primo studio, prospettico, è stato quello di determinare lo spessore ecografico dei singoli strati di parete nell’intestino tenue in una popolazione di gatti sani. Lo strato mucoso è risultato significativamente più spesso nel duodeno e nel digiuno, per la maggiore grandezza dei villi in queste porzioni dell’intestino tenue. A livello dell’ileo, gli strati di maggior spessore sono risultati quello sottomucoso, per l’abbondante presenza di aggregati linfoidi, e quello muscolare, a causa delle caratteristiche anatomo-funzionali di sfintere che questo tratto intestinale svolge. Il secondo progetto, retrospettivo, nasce dalla collaborazione tra due centri universitari, uno italiano e uno americano, con l’obiettivo di confrontare lo spessore della tonaca muscolare intestinale in gatti affetti da Inflammatory Bowel disease (IBD) o da neoplasie intestinali. In questo studio, l’ipertrofia della tonaca muscolare (ITM) è stato maggiormente osservato in gatti con IBD rispetto a gatti con neoplasie intestinali, ma non sono state evidenziate differenze di spessore della tonaca muscolare tali da poter differenziare le due patologie. Lo scopo del terzo progetto, prospettico, è stato quello di descrivere il pattern di perfusione parietale del piccolo intestino, valutato mediante uso di mezzo di contrasto ecografico, in gatti con ITM associata a IBD. In tutti gli animali studiati, l’ITM si è associato a una modesta assunzione del mezzo di contrasto rispetto agli altri strati della parete intestinale. Questi risultati confermano che l’ITM che si osserva in gatti con IBD non è associato a significativi aumenti della vascolarizzazione di tale strato parietale.
Resumo:
Introduzione: L’indicazione alla rivascolarizzazione carotidea è comunemente posta in base alla percentuale di stenosi, alla presenza di sintomi neurologici ed alle condizioni cliniche del paziente. Una placca ad elevato potenziale embolico viene definita “vulnerabile”; la sua caratterizzazione, tuttavia, non è universalmente accettata ai fini della rivascolarizzazione. Lo scopo dello studio è indagare il ruolo del mezzo di contrasto ecografico (CEUS) nell’identificazione della placca carotidea vulnerabile. Materiali e Metodi: I pazienti sottoposti a endoarterectomia carotidea, sono stati valutati mediante TC cerebrale preoperatoria e CEUS. Le microbolle di contrasto rilevate nella placca, indicative di neovascolarizzazione, sono state quantificate in dB-E ed istologicamente valutate per cinque caratteristiche: (densità dei microvasi, spessore del cappuccio fibroso, estensione delle calcificazioni, infiltrato infiammatorio e core lipidico) il valore da 1 a 5, ottenuto in cieco, indica in grado di vulnerabilità della placca. L'ANOVA test, il test di Fisher e t Student sono stati usati per correlare le caratteristiche dei pazienti ed istologiche col valore di dB-E. Risultati: Di 22 pazienti (range 2-7.8, media 4.85 ±1.9 SD) vi era un numero più alto di sintomatici (7.40 ± 0.5) rispetto agli asintomatici (3.5 ± 1.4) (p = 0.002). Un più alto valore di dB-E si associava con la presenza di un sottile cappuccino fibroso (<200 µm, 5.96±1.5 vs. 3 ± 1,p = 0.01) ed un maggiore infiltrato infiammatorio (3.2 ± 0.9 vs. 6.4 ± 1.2, p = 0.03). Placche con vulnerabilità 5 si associavano ad un valore più alto di dB-E rispetto alle placche con vulnerabilità 1 (7.6 ± 0.2 vs. 2.5 ± 0.6, rispettivamente, p=0.001). Preoperatoriamente, le lesioni emboliche ipsilaterali alla TC, correlavano con un più alto valore di dB-E (5.96±1.5 vs. 3.0±1.0, p=0.01). Conclusioni: Il valore di dB-E alla CEUS indica l’estensione della neovascolarizzazione della placca carotidea e può essere utilizzato come marker di vulnerabilità della placca.