9 resultados para Third-order correlation

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 2D Unconstrained Third Order Shear Deformation Theory (UTSDT) is presented for the evaluation of tangential and normal stresses in moderately thick functionally graded conical and cylindrical shells subjected to mechanical loadings. Several types of graded materials are investigated. The functionally graded material consists of ceramic and metallic constituents. A four parameter power law function is used. The UTSDT allows the presence of a finite transverse shear stress at the top and bottom surfaces of the graded shell. In addition, the initial curvature effect included in the formulation leads to the generalization of the present theory (GUTSDT). The Generalized Differential Quadrature (GDQ) method is used to discretize the derivatives in the governing equations, the external boundary conditions and the compatibility conditions. Transverse and normal stresses are also calculated by integrating the three dimensional equations of equilibrium in the thickness direction. In this way, the six components of the stress tensor at a point of the conical or cylindrical shell or panel can be given. The initial curvature effect and the role of the power law functions are shown for a wide range of functionally conical and cylindrical shells under various loading and boundary conditions. Finally, numerical examples of the available literature are worked out.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We observed 82 healthy subjects, from both sexes, aged between 19 and 77 years. All subjects performed two different tests: for being scientifically acknowledged, the first one was used as a reference and it was a stress test (CPX). During the entire test, heart rate and gas exchange were recorded continuously; the second, the actual object of this study, was a submaximal test (TOP). Only heart rate was recorded continuously. The main purpose was to determinate an index of physical fitness as result of TOP. CPX test allowed us to individuate anaerobic threshold. We used an incremental protocol of 10/20 Watt/min, different by age. For our TOP test we used an RHC400 UPRIGHT BIKE, by Air Machine. Each subject was monitored for heart frequency. After 2 minutes of resting period there was a first step: 3 minutes of pedalling at a constant rate of 60 RPM, (40 watts for elder subjects and 60 watts for the younger ones). Then, the subject was allowed to rest for a recovery phase of 5 minutes. Third and last step consisted of 3 minutes of pedalling again at 60 RPM but now set to 60 watts for elder subjects and 80 watts for the young subjects. Finally another five minutes of recovery. A good correlation was found between TOP and CPX results especially between punctua l heart rate reserve (HRR’) and anaerobic threshold parameters such as Watt, VO2, VCO2 . HRR’ was obtained by subtracting maximal heart rate during TOP from maximal theoretic heart rate (206,9-(0,67*age)). Data were analyzed through cluster analysis in order to obtain 3 homogeneous groups. The first group contains the least fit subjects (inactive, women, elderly). The other groups contain the “average fit” and the fittest subjects (active, men, younger). Concordance between test resulted in 83,23%. Afterwards, a linear combinations of the most relevant variables gave us a formula to classify people in the correct group. The most relevant result is that this submaximal test is able to discriminate subjects with different physical condition and to provide information (index) about physical fitness through HRR’. Compared to a traditional incremental stress test, the very low load of TOP, short duration and extended resting period, make this new method suitable to very different people. To better define the TOP index, it is necessary to enlarge our subject sample especially by diversifying the age range.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Extensive literature outlined that the quality of the mother-foetus relationship is considered the main feature with regard to the quality of postnatal mother-infant interaction and also to the child’s psychical development. Nowadays the relationship between the pregnant woman and her foetus is viewed as the central factor of the somatic dialogue between the functioning of the maternal and the foetal organisms. This dialogue is responsible for the physic development of the child, as well as of its psychosomatic structure. Therefore the research area has necessarily had to extend to the analysis of psychological processes concerning: the pregnancy, the couple that is bound by parenthood, the influence of intergenerational dynamics. In fact, the formation of maternal identity, as well as that of the relationship between the woman and the foetus, refers to the pregnant woman’s relationship with her parents, especially with her mother. The same pregnancy, considered as a psychosomatic event, is directly influenced by relational, affective and social factors, particularly by the quality of the interiorized parental relations and the quality of the current relationships (such as that with her partner and with her family of origin). Some studies have begun to investigate the relationship between the pregnant woman and the foetus in term of “prenatal attachment” and its relationship with socio-demographic, psychological e psychopathological aspects (such as pre and post partum depression), but the research area is still largely unexplored. The present longitudinal research aimed to investigate the quality of the pregnant womanfoetus relationship by the prenatal attachment index, the quality of the interiorized relationship with woman’s parents, the level of alexithymic features and maternity social support, in relation with the modulation of the physiology of delivery and of postpartum, as well as of the physical development of the child. A consecutive sample of 62 Italian primipara women without any kind of pathologies, participated in the longitudinal study. In the first phase of this study (third trimester of the pregnancy), it has investigated the psychological processes connected to the affective investment of the pregnant women towards the unborn baby (by Prenatal Attachment Inventory), the mothers’ interiorized relationship with their own parents (by Parental Bonding Instrument), the social and affective support from their partner and their family of origin are able to supply (by Maternity Social Support Scale), and the level of alexithymia (by 20-Toronto Alexithymia Scale). In the second phase of this study, some data concerning the childbirth course carried out from a “deliverygram” (such as labour, induction durations and modalities of delivery) and data relative to the newborns state of well-being (such as Apgar and pH indexes). Finally, in the third phase of the study women have been telephoned a month after the childbirth. The semistructured interview investigated the following areas: the memory concerning the delivery, the return to home, the first interactions between the mother and the newborn, the breastfeeding, the biological rhythms achieved from newborns. From the data analysis a sample with a good level of prenatal attachment and of support social and a good capability to mental functioning emerged. An interesting result is that the most of the women have a great percentage of “affectionless control style” with both parents, but data is not sufficient to interpret this result. Moreover, considering the data relative to the delivery, medical and welfare procedures, that have been necessary, are coherent with the Italian mean, while the percentage of the caesarean section (12.9%) is inferior to the national percentage (30%). The 29% of vaginal partum has got epidural analgesia, which explains the high number (37%) of obstetrician operations (such as Kristeller). The data relative to the newborn (22 male, 40 female) indicates a good state of well-being because Apgar and pH indexes are superior to 7 at first and fifth minutes. Concerning the prenatal phase, correlation analysis showed that: the prenatal attachment scores positively correlated with the expected social support and negatively correlated with the “externally oriented thinking” dimension of alexithymia; the maternity social support negatively correlated with total alexithymia score, particularly with the “externally oriented thinking” dimension, and negatively correlated with maternal control of parental bonding. Concerning the delivery data, there are many correlations (after all obvious) among themselves. The most important are that the labour duration negatively correlated with the newborn’s index state of well-being. Finally, concerning the data from the postpartum phase the women’ assessments relative to the partum negatively correlated with the duration of the delivery and positively correlated with the assessment relative to the return to home and the interaction with the newborn. Moreover the length of permanence in the hospital negatively correlated with women’s assessments relative to the return to home that, in turn, positively correlated with the quality of breastfeeding, the interaction between the mother and the newborn and the biological regulation of the child. Finally, the women’ assessments relative to breastfeeding positively correlated with the mother-child interactions and the biological rhythms of children. From the correlation analysis between the variables of the prenatal phase and the data relative to the delivery, emerged that the prenatal attachment scores positively correlated with the dilatation stage scores and with the newborn’s Apgar index at first minute, the paternal care dimension of parental bonding positively correlated with the lengths of the various periods of childbirth like so the paternal control dimension with placental stage. Moreover, emerged that the expected social support positively correlated with the lengths of the various periods of childbirth and that the global alexithymia scores, particularly “difficulty to describe emotions” dimension, negatively correlated with total childbirth scores. From the correlation analysis between the variables of the prenatal phase and variable of the postpartum phase emerged that the total alexithymia scores positively correlated with the time elapsed from the childbirth to the breastfeeding of the child, the difficulty to describe emotions dimension of the alexithymia negatively correlated with the quality of the breastfeeding, the “externally oriented thinking” dimension of the alexithymia negatively correlated with mother-child interactions, and finally the paternal control dimension of the parental bonding negatively correlated with the time elapsed from the child to the breastfeeding of the child. Finally, from the analysis of the correlation between the data of the partum and the women’s assessments of the postpartum phase, emerged the negative correlation between the woman’s assessment relative to the delivery and the quantitative of obstetrician operations and the lengths of the various periods of childbirth, the positive correlation between the women’s assessment about the length of delivery periods and the real lengths of the same ones, the positive relation between woman’s assessment relative to the delivery and the Apgar index of children. In conclusion, there is a remarkable relation between the quality of the relationship the woman establishes with the foetus that influences the course of the pregnancy and the delivery that, in turn, influences the postpartum outcome, particularly relative to the mother-children relationship. Such data should be confirmed by heterogeneous populations in order to identify vulnerable women and to project focused intervention.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today’s pet food industry is growing rapidly, with pet owners demanding high-quality diets for their pets. The primary role of diet is to provide enough nutrients to meet metabolic requirements, while giving the consumer a feeling of well-being. Diet nutrient composition and digestibility are of crucial importance for health and well being of animals. A recent strategy to improve the quality of food is the use of “nutraceuticals” or “Functional foods”. At the moment, probiotics and prebiotics are among the most studied and frequently used functional food compounds in pet foods. The present thesis reported results from three different studies. The first study aimed to develop a simple laboratory method to predict pet foods digestibility. The developed method was based on the two-step multi-enzymatic incubation assay described by Vervaeke et al. (1989), with some modification in order to better represent the digestive physiology of dogs. A trial was then conducted to compare in vivo digestibility of pet-foods and in vitro digestibility using the newly developed method. Correlation coefficients showed a close correlation between digestibility data of total dry matter and crude protein obtained with in vivo and in vitro methods (0.9976 and 0.9957, respectively). Ether extract presented a lower correlation coefficient, although close to 1 (0.9098). Based on the present results, the new method could be considered as an alternative system of evaluation of dog foods digestibility, reducing the need for using experimental animals in digestibility trials. The second parte of the study aimed to isolate from dog faeces a Lactobacillus strain capable of exert a probiotic effect on dog intestinal microflora. A L. animalis strain was isolated from the faeces of 17 adult healthy dogs..The isolated strain was first studied in vitro when it was added to a canine faecal inoculum (at a final concentration of 6 Log CFU/mL) that was incubated in anaerobic serum bottles and syringes which simulated the large intestine of dogs. Samples of fermentation fluid were collected at 0, 4, 8, and 24 hours for analysis (ammonia, SCFA, pH, lactobacilli, enterococci, coliforms, clostridia). Consequently, the L. animalis strain was fed to nine dogs having lactobacilli counts lower than 4.5 Log CFU per g of faeces. The study indicated that the L animalis strain was able to survive gastrointestinal passage and transitorily colonize the dog intestine. Both in vitro and in vivo results showed that the L. animalis strain positively influenced composition and metabolism of the intestinal microflora of dogs. The third trail investigated in vitro the effects of several non-digestible oligosaccharides (NDO) on dog intestinal microflora composition and metabolism. Substrates were fermented using a canine faecal inoculum that was incubated in anaerobic serum bottles and syringes. Substrates were added at the final concentration of 1g/L (inulin, FOS, pectin, lactitol, gluconic acid) or 4g/L (chicory). Samples of fermentation fluid were collected at 0, 6, and 24 hours for analysis (ammonia, SCFA, pH, lactobacilli, enterococci, coliforms). Gas production was measured throughout the 24 h of the study. Among the tested NDO lactitol showed the best prebiotic properties. In fact, it reduced coliforms and increased lactobacilli counts, enhanced microbial fermentation and promoted the production of SCFA while decreasing BCFA. All the substrates that were investigated showed one or more positive effects on dog faecal microflora metabolism or composition. Further studies (in particular in vivo studies with dogs) will be needed to confirm the prebiotic properties of lactitol and evaluate its optimal level of inclusion in the diet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The treatment of the Cerebral Palsy (CP) is considered as the “core problem” for the whole field of the pediatric rehabilitation. The reason why this pathology has such a primary role, can be ascribed to two main aspects. First of all CP is the form of disability most frequent in childhood (one new case per 500 birth alive, (1)), secondarily the functional recovery of the “spastic” child is, historically, the clinical field in which the majority of the therapeutic methods and techniques (physiotherapy, orthotic, pharmacologic, orthopedic-surgical, neurosurgical) were first applied and tested. The currently accepted definition of CP – Group of disorders of the development of movement and posture causing activity limitation (2) – is the result of a recent update by the World Health Organization to the language of the International Classification of Functioning Disability and Health, from the original proposal of Ingram – A persistent but not unchangeable disorder of posture and movement – dated 1955 (3). This definition considers CP as a permanent ailment, i.e. a “fixed” condition, that however can be modified both functionally and structurally by means of child spontaneous evolution and treatments carried out during childhood. The lesion that causes the palsy, happens in a structurally immature brain in the pre-, peri- or post-birth period (but only during the firsts months of life). The most frequent causes of CP are: prematurity, insufficient cerebral perfusion, arterial haemorrhage, venous infarction, hypoxia caused by various origin (for example from the ingestion of amniotic liquid), malnutrition, infection and maternal or fetal poisoning. In addition to these causes, traumas and malformations have to be included. The lesion, whether focused or spread over the nervous system, impairs the whole functioning of the Central Nervous System (CNS). As a consequence, they affect the construction of the adaptive functions (4), first of all posture control, locomotion and manipulation. The palsy itself does not vary over time, however it assumes an unavoidable “evolutionary” feature when during growth the child is requested to meet new and different needs through the construction of new and different functions. It is essential to consider that clinically CP is not only a direct expression of structural impairment, that is of etiology, pathogenesis and lesion timing, but it is mainly the manifestation of the path followed by the CNS to “re”-construct the adaptive functions “despite” the presence of the damage. “Palsy” is “the form of the function that is implemented by an individual whose CNS has been damaged in order to satisfy the demands coming from the environment” (4). Therefore it is only possible to establish general relations between lesion site, nature and size, and palsy and recovery processes. It is quite common to observe that children with very similar neuroimaging can have very different clinical manifestations of CP and, on the other hand, children with very similar motor behaviors can have completely different lesion histories. A very clear example of this is represented by hemiplegic forms, which show bilateral hemispheric lesions in a high percentage of cases. The first section of this thesis is aimed at guiding the interpretation of CP. First of all the issue of the detection of the palsy is treated from historical viewpoint. Consequently, an extended analysis of the current definition of CP, as internationally accepted, is provided. The definition is then outlined in terms of a space dimension and then of a time dimension, hence it is highlighted where this definition is unacceptably lacking. The last part of the first section further stresses the importance of shifting from the traditional concept of CP as a palsy of development (defect analysis) towards the notion of development of palsy, i.e., as the product of the relationship that the individual however tries to dynamically build with the surrounding environment (resource semeiotics) starting and growing from a different availability of resources, needs, dreams, rights and duties (4). In the scientific and clinic community no common classification system of CP has so far been universally accepted. Besides, no standard operative method or technique have been acknowledged to effectively assess the different disabilities and impairments exhibited by children with CP. CP is still “an artificial concept, comprising several causes and clinical syndromes that have been grouped together for a convenience of management” (5). The lack of standard and common protocols able to effectively diagnose the palsy, and as a consequence to establish specific treatments and prognosis, is mainly because of the difficulty to elevate this field to a level based on scientific evidence. A solution aimed at overcoming the current incomplete treatment of CP children is represented by the clinical systematic adoption of objective tools able to measure motor defects and movement impairments. A widespread application of reliable instruments and techniques able to objectively evaluate both the form of the palsy (diagnosis) and the efficacy of the treatments provided (prognosis), constitutes a valuable method able to validate care protocols, establish the efficacy of classification systems and assess the validity of definitions. Since the ‘80s, instruments specifically oriented to the analysis of the human movement have been advantageously designed and applied in the context of CP with the aim of measuring motor deficits and, especially, gait deviations. The gait analysis (GA) technique has been increasingly used over the years to assess, analyze, classify, and support the process of clinical decisions making, allowing for a complete investigation of gait with an increased temporal and spatial resolution. GA has provided a basis for improving the outcome of surgical and nonsurgical treatments and for introducing a new modus operandi in the identification of defects and functional adaptations to the musculoskeletal disorders. Historically, the first laboratories set up for gait analysis developed their own protocol (set of procedures for data collection and for data reduction) independently, according to performances of the technologies available at that time. In particular, the stereophotogrammetric systems mainly based on optoelectronic technology, soon became a gold-standard for motion analysis. They have been successfully applied especially for scientific purposes. Nowadays the optoelectronic systems have significantly improved their performances in term of spatial and temporal resolution, however many laboratories continue to use the protocols designed on the technology available in the ‘70s and now out-of-date. Furthermore, these protocols are not coherent both for the biomechanical models and for the adopted collection procedures. In spite of these differences, GA data are shared, exchanged and interpreted irrespectively to the adopted protocol without a full awareness to what extent these protocols are compatible and comparable with each other. Following the extraordinary advances in computer science and electronics, new systems for GA no longer based on optoelectronic technology, are now becoming available. They are the Inertial and Magnetic Measurement Systems (IMMSs), based on miniature MEMS (Microelectromechanical systems) inertial sensor technology. These systems are cost effective, wearable and fully portable motion analysis systems, these features gives IMMSs the potential to be used both outside specialized laboratories and to consecutive collect series of tens of gait cycles. The recognition and selection of the most representative gait cycle is then easier and more reliable especially in CP children, considering their relevant gait cycle variability. The second section of this thesis is focused on GA. In particular, it is firstly aimed at examining the differences among five most representative GA protocols in order to assess the state of the art with respect to the inter-protocol variability. The design of a new protocol is then proposed and presented with the aim of achieving gait analysis on CP children by means of IMMS. The protocol, named ‘Outwalk’, contains original and innovative solutions oriented at obtaining joint kinematic with calibration procedures extremely comfortable for the patients. The results of a first in-vivo validation of Outwalk on healthy subjects are then provided. In particular, this study was carried out by comparing Outwalk used in combination with an IMMS with respect to a reference protocol and an optoelectronic system. In order to set a more accurate and precise comparison of the systems and the protocols, ad hoc methods were designed and an original formulation of the statistical parameter coefficient of multiple correlation was developed and effectively applied. On the basis of the experimental design proposed for the validation on healthy subjects, a first assessment of Outwalk, together with an IMMS, was also carried out on CP children. The third section of this thesis is dedicated to the treatment of walking in CP children. Commonly prescribed treatments in addressing gait abnormalities in CP children include physical therapy, surgery (orthopedic and rhizotomy), and orthoses. The orthotic approach is conservative, being reversible, and widespread in many therapeutic regimes. Orthoses are used to improve the gait of children with CP, by preventing deformities, controlling joint position, and offering an effective lever for the ankle joint. Orthoses are prescribed for the additional aims of increasing walking speed, improving stability, preventing stumbling, and decreasing muscular fatigue. The ankle-foot orthosis (AFO), with a rigid ankle, are primarily designed to prevent equinus and other foot deformities with a positive effect also on more proximal joints. However, AFOs prevent the natural excursion of the tibio-tarsic joint during the second rocker, hence hampering the natural leaning progression of the whole body under the effect of the inertia (6). A new modular (submalleolar) astragalus-calcanear orthosis, named OMAC, has recently been proposed with the intention of substituting the prescription of AFOs in those CP children exhibiting a flat and valgus-pronated foot. The aim of this section is thus to present the mechanical and technical features of the OMAC by means of an accurate description of the device. In particular, the integral document of the deposited Italian patent, is provided. A preliminary validation of OMAC with respect to AFO is also reported as resulted from an experimental campaign on diplegic CP children, during a three month period, aimed at quantitatively assessing the benefit provided by the two orthoses on walking and at qualitatively evaluating the changes in the quality of life and motor abilities. As already stated, CP is universally considered as a persistent but not unchangeable disorder of posture and movement. Conversely to this definition, some clinicians (4) have recently pointed out that movement disorders may be primarily caused by the presence of perceptive disorders, where perception is not merely the acquisition of sensory information, but an active process aimed at guiding the execution of movements through the integration of sensory information properly representing the state of one’s body and of the environment. Children with perceptive impairments show an overall fear of moving and the onset of strongly unnatural walking schemes directly caused by the presence of perceptive system disorders. The fourth section of the thesis thus deals with accurately defining the perceptive impairment exhibited by diplegic CP children. A detailed description of the clinical signs revealing the presence of the perceptive impairment, and a classification scheme of the clinical aspects of perceptual disorders is provided. In the end, a functional reaching test is proposed as an instrumental test able to disclosure the perceptive impairment. References 1. Prevalence and characteristics of children with cerebral palsy in Europe. Dev Med Child Neurol. 2002 Set;44(9):633-640. 2. Bax M, Goldstein M, Rosenbaum P, Leviton A, Paneth N, Dan B, et al. Proposed definition and classification of cerebral palsy, April 2005. Dev Med Child Neurol. 2005 Ago;47(8):571-576. 3. Ingram TT. A study of cerebral palsy in the childhood population of Edinburgh. Arch. Dis. Child. 1955 Apr;30(150):85-98. 4. Ferrari A, Cioni G. The spastic forms of cerebral palsy : a guide to the assessment of adaptive functions. Milan: Springer; 2009. 5. Olney SJ, Wright MJ. Cerebral Palsy. Campbell S et al. Physical Therapy for Children. 2nd Ed. Philadelphia: Saunders. 2000;:533-570. 6. Desloovere K, Molenaers G, Van Gestel L, Huenaerts C, Van Campenhout A, Callewaert B, et al. How can push-off be preserved during use of an ankle foot orthosis in children with hemiplegia? A prospective controlled study. Gait Posture. 2006 Ott;24(2):142-151.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose an extension of the approach provided by Kluppelberg and Kuhn (2009) for inference on second-order structure moments. As in Kluppelberg and Kuhn (2009) we adopt a copula-based approach instead of assuming normal distribution for the variables, thus relaxing the equality in distribution assumption. A new copula-based estimator for structure moments is investigated. The methodology provided by Kluppelberg and Kuhn (2009) is also extended considering the copulas associated with the family of Eyraud-Farlie-Gumbel-Morgenstern distribution functions (Kotz, Balakrishnan, and Johnson, 2000, Equation 44.73). Finally, a comprehensive simulation study and an application to real financial data are performed in order to compare the different approaches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

III-nitride materials are very promising for high speed electronics/optical applications but still suffer in performance due to problems during high quality epitaxial growth, evolution of dislocation and defects, less understanding of fundamental physics of materials/processing of devices etc. This thesis mainly focus on GaN based heterostructures to understand the metal-semiconductor interface properties, 2DE(H)G influence on electrical and optical properties, and deep level states in GaN and InAlN, InGaN materials. The detailed electrical characterizations have been employed on Schottky diodes at GaN and InAl(Ga)N/GaN heterostructures in order to understand the metal-semiconductor interface related properties in these materials. I have observed the occurrence of Schottky barrier inhomogenity, role of dislocations in terms of leakage and creating electrically active defect states within energy gap of materials. Deep level transient spectroscopy method is employed on GaN, InAlN and InGaN materials and several defect levels have been observed related to majority and minority carriers. In fact, some defects have been found common in characteristics in ternary layers and GaN layer which indicates that those defect levels are from similar origin, most probably due to Ga/N vacancy in GaN/heterostructures. The role of structural defects, roughness has been extensively understood in terms of enhancing the reverse leakage current, suppressing the mobility in InAlN/AlN/GaN based high electron mobility transistor (HEMT) structures which are identified as key issues for GaN technology. Optical spectroscopy methods have been employed to understand materials quality, sub band and defect related transitions and compared with electrical characterizations. The observation of 2DEG sub band related absorption/emission in optical spectra have been identified and proposed for first time in nitride based polar heterostructures, which is well supported with simulation results. In addition, metal-semiconductor-metal (MSM)-InAl(Ga)N/GaN based photodetector structures have been fabricated and proposed for achieving high efficient optoelectronics devices in future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

From the late 1980s, the automation of sequencing techniques and the computer spread gave rise to a flourishing number of new molecular structures and sequences and to proliferation of new databases in which to store them. Here are presented three computational approaches able to analyse the massive amount of publicly avalilable data in order to answer to important biological questions. The first strategy studies the incorrect assignment of the first AUG codon in a messenger RNA (mRNA), due to the incomplete determination of its 5' end sequence. An extension of the mRNA 5' coding region was identified in 477 in human loci, out of all human known mRNAs analysed, using an automated expressed sequence tag (EST)-based approach. Proof-of-concept confirmation was obtained by in vitro cloning and sequencing for GNB2L1, QARS and TDP2 and the consequences for the functional studies are discussed. The second approach analyses the codon bias, the phenomenon in which distinct synonymous codons are used with different frequencies, and, following integration with a gene expression profile, estimates the total number of codons present across all the expressed mRNAs (named here "codonome value") in a given biological condition. Systematic analyses across different pathological and normal human tissues and multiple species shows a surprisingly tight correlation between the codon bias and the codonome bias. The third approach is useful to studies the expression of human autism spectrum disorder (ASD) implicated genes. ASD implicated genes sharing microRNA response elements (MREs) for the same microRNA are co-expressed in brain samples from healthy and ASD affected individuals. The different expression of a recently identified long non coding RNA which have four MREs for the same microRNA could disrupt the equilibrium in this network, but further analyses and experiments are needed.