3 resultados para The Power of Kangwon Province

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Treaty of Lisbon has brought remarkable changes and innovations to the European Union. As far as the Council of Ministers of the European Union (“the Council” hereinafter) is concerned, there are two significant innovations: double qualified majority voting and new rotating Presidency scheme, which are considered to make the working of the Council more efficiently, stably and consistently. With the modification relating to other key institutions, the Commission and the European Parliament, and with certain procedures being re-codified, the power of the Council varies accordingly, where the inter-institutional balance counts for more research. As the Council is one of the co-legislatures of the Union, the legislative function of it would be probably influenced, positively or negatively, by the internal innovations and the inter-institutional re-balance. Has the legislative function of the Council been reinforced or not? How could the Council better reach its functional goal designed by the Treaties’ drafter? How to evaluate the Council’s evolution after Lisbon Treaty in the light of European integration? This thesis is attempting to find the answers by analyzing two main internal innovations and inter-institutional re-balance thereinafter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to identify markers associated with production traits in the pig genome using different approaches. We focused the attention on Italian Large White pig breed using Genome Wide Association Studies (GWAS) and applying a selective genotyping approach to increase the power of the analyses. Furthermore, we searched the pig genome using Next Generation Sequencing (NSG) Ion Torrent Technology to combine selective genotyping approach and deep sequencing for SNP discovery. Other two studies were carried on with a different approach. Allele frequency changes for SNPs affecting candidate genes and at Genome Wide level were analysed to identify selection signatures driven by selection program during the last 20 years. This approach confirmed that a great number of markers may affect production traits and that they are captured by the classical selection programs. GWAS revealed 123 significant or suggestively significant SNP associated with Back Fat Thickenss and 229 associated with Average Daily Gain. 16 Copy Number Variant Regions resulted more frequent in lean or fat pigs and showed that different copies of those region could have a limited impact on fat. These often appear to be involved in food intake and behavior, beside affecting genes involved in metabolic pathways and their expression. By combining NGS sequencing with selective genotyping approach, new variants where discovered and at least 54 are worth to be analysed in association studies. The study of groups of pigs undergone to stringent selection showed that allele frequency of some loci can drastically change if they are close to traits that are interesting for selection schemes. These approaches could be, in future, integrated in genomic selection plans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research activity carried out during the PhD course in Electrical Engineering belongs to the branch of electric and electronic measurements. The main subject of the present thesis is a distributed measurement system to be installed in Medium Voltage power networks, as well as the method developed to analyze data acquired by the measurement system itself and to monitor power quality. In chapter 2 the increasing interest towards power quality in electrical systems is illustrated, by reporting the international research activity inherent to the problem and the relevant standards and guidelines emitted. The aspect of the quality of voltage provided by utilities and influenced by customers in the various points of a network came out only in recent years, in particular as a consequence of the energy market liberalization. Usually, the concept of quality of the delivered energy has been associated mostly to its continuity. Hence the reliability was the main characteristic to be ensured for power systems. Nowadays, the number and duration of interruptions are the “quality indicators” commonly perceived by most customers; for this reason, a short section is dedicated also to network reliability and its regulation. In this contest it should be noted that although the measurement system developed during the research activity belongs to the field of power quality evaluation systems, the information registered in real time by its remote stations can be used to improve the system reliability too. Given the vast scenario of power quality degrading phenomena that usually can occur in distribution networks, the study has been focused on electromagnetic transients affecting line voltages. The outcome of such a study has been the design and realization of a distributed measurement system which continuously monitor the phase signals in different points of a network, detect the occurrence of transients superposed to the fundamental steady state component and register the time of occurrence of such events. The data set is finally used to locate the source of the transient disturbance propagating along the network lines. Most of the oscillatory transients affecting line voltages are due to faults occurring in any point of the distribution system and have to be seen before protection equipment intervention. An important conclusion is that the method can improve the monitored network reliability, since the knowledge of the location of a fault allows the energy manager to reduce as much as possible both the area of the network to be disconnected for protection purposes and the time spent by technical staff to recover the abnormal condition and/or the damage. The part of the thesis presenting the results of such a study and activity is structured as follows: chapter 3 deals with the propagation of electromagnetic transients in power systems by defining characteristics and causes of the phenomena and briefly reporting the theory and approaches used to study transients propagation. Then the state of the art concerning methods to detect and locate faults in distribution networks is presented. Finally the attention is paid on the particular technique adopted for the same purpose during the thesis, and the methods developed on the basis of such approach. Chapter 4 reports the configuration of the distribution networks on which the fault location method has been applied by means of simulations as well as the results obtained case by case. In this way the performance featured by the location procedure firstly in ideal then in realistic operating conditions are tested. In chapter 5 the measurement system designed to implement the transients detection and fault location method is presented. The hardware belonging to the measurement chain of every acquisition channel in remote stations is described. Then, the global measurement system is characterized by considering the non ideal aspects of each device that can concur to the final combined uncertainty on the estimated position of the fault in the network under test. Finally, such parameter is computed according to the Guide to the Expression of Uncertainty in Measurements, by means of a numeric procedure. In the last chapter a device is described that has been designed and realized during the PhD activity aiming at substituting the commercial capacitive voltage divider belonging to the conditioning block of the measurement chain. Such a study has been carried out aiming at providing an alternative to the used transducer that could feature equivalent performance and lower cost. In this way, the economical impact of the investment associated to the whole measurement system would be significantly reduced, making the method application much more feasible.