4 resultados para Shield-emblem

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several activities were conducted during my PhD activity. For the NEMO experiment a collaboration between the INFN/University groups of Catania and Bologna led to the development and production of a mixed signal acquisition board for the Nemo Km3 telescope. The research concerned the feasibility study for a different acquisition technique quite far from that adopted in the NEMO Phase 1 telescope. The DAQ board that we realized exploits the LIRA06 front-end chip for the analog acquisition of anodic an dynodic sources of a PMT (Photo-Multiplier Tube). The low-power analog acquisition allows to sample contemporaneously multiple channels of the PMT at different gain factors in order to increase the signal response linearity over a wider dynamic range. Also the auto triggering and self-event-classification features help to improve the acquisition performance and the knowledge on the neutrino event. A fully functional interface towards the first level data concentrator, the Floor Control Module, has been integrated as well on the board, and a specific firmware has been realized to comply with the present communication protocols. This stage of the project foresees the use of an FPGA, a high speed configurable device, to provide the board with a flexible digital logic control core. After the validation of the whole front-end architecture this feature would be probably integrated in a common mixed-signal ASIC (Application Specific Integrated Circuit). The volatile nature of the configuration memory of the FPGA implied the integration of a flash ISP (In System Programming) memory and a smart architecture for a safe remote reconfiguration of it. All the integrated features of the board have been tested. At the Catania laboratory the behavior of the LIRA chip has been investigated in the digital environment of the DAQ board and we succeeded in driving the acquisition with the FPGA. The PMT pulses generated with an arbitrary waveform generator were correctly triggered and acquired by the analog chip, and successively they were digitized by the on board ADC under the supervision of the FPGA. For the communication towards the data concentrator a test bench has been realized in Bologna where, thanks to a lending of the Roma University and INFN, a full readout chain equivalent to that present in the NEMO phase-1 was installed. These tests showed a good behavior of the digital electronic that was able to receive and to execute command imparted by the PC console and to answer back with a reply. The remotely configurable logic behaved well too and demonstrated, at least in principle, the validity of this technique. A new prototype board is now under development at the Catania laboratory as an evolution of the one described above. This board is going to be deployed within the NEMO Phase-2 tower in one of its floors dedicated to new front-end proposals. This board will integrate a new analog acquisition chip called SAS (Smart Auto-triggering Sampler) introducing thus a new analog front-end but inheriting most of the digital logic present in the current DAQ board discussed in this thesis. For what concern the activity on high-resolution vertex detectors, I worked within the SLIM5 collaboration for the characterization of a MAPS (Monolithic Active Pixel Sensor) device called APSEL-4D. The mentioned chip is a matrix of 4096 active pixel sensors with deep N-well implantations meant for charge collection and to shield the analog electronics from digital noise. The chip integrates the full-custom sensors matrix and the sparsifification/readout logic realized with standard-cells in STM CMOS technology 130 nm. For the chip characterization a test-beam has been set up on the 12 GeV PS (Proton Synchrotron) line facility at CERN of Geneva (CH). The collaboration prepared a silicon strip telescope and a DAQ system (hardware and software) for data acquisition and control of the telescope that allowed to store about 90 million events in 7 equivalent days of live-time of the beam. My activities concerned basically the realization of a firmware interface towards and from the MAPS chip in order to integrate it on the general DAQ system. Thereafter I worked on the DAQ software to implement on it a proper Slow Control interface of the APSEL4D. Several APSEL4D chips with different thinning have been tested during the test beam. Those with 100 and 300 um presented an overall efficiency of about 90% imparting a threshold of 450 electrons. The test-beam allowed to estimate also the resolution of the pixel sensor providing good results consistent with the pitch/sqrt(12) formula. The MAPS intrinsic resolution has been extracted from the width of the residual plot taking into account the multiple scattering effect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This PhD thesis discusses the rationale for design and use of synthetic oligosaccharides for the development of glycoconjugate vaccines and the role of physicochemical methods in the characterization of these vaccines. The study concerns two infectious diseases that represent a serious problem for the national healthcare programs: human immunodeficiency virus (HIV) and Group A Streptococcus (GAS) infections. Both pathogens possess distinctive carbohydrate structures that have been described as suitable targets for the vaccine design. The Group A Streptococcus cell membrane polysaccharide (GAS-PS) is an attractive vaccine antigen candidate based on its conserved, constant expression pattern and the ability to confer immunoprotection in a relevant mouse model. Analysis of the immunogenic response within at-risk populations suggests an inverse correlation between high anti-GAS-PS antibody titres and GAS infection cases. Recent studies show that a chemically synthesized core polysaccharide-based antigen may represent an antigenic structural determinant of the large polysaccharide. Based on GAS-PS structural analysis, the study evaluates the potential to exploit a synthetic design approach to GAS vaccine development and compares the efficiency of synthetic antigens with the long isolated GAS polysaccharide. Synthetic GAS-PS structural analogues were specifically designed and generated to explore the impact of antigen length and terminal residue composition. For the HIV-1 glycoantigens, the dense glycan shield on the surface of the envelope protein gp120 was chosen as a target. This shield masks conserved protein epitopes and facilitates virus spread via binding to glycan receptors on susceptible host cells. The broadly neutralizing monoclonal antibody 2G12 binds a cluster of high-mannose oligosaccharides on the gp120 subunit of HIV-1 Env protein. This oligomannose epitope has been a subject to the synthetic vaccine development. The cluster nature of the 2G12 epitope suggested that multivalent antigen presentation was important to develop a carbohydrate based vaccine candidate. I describe the development of neoglycoconjugates displaying clustered HIV-1 related oligomannose carbohydrates and their immunogenic properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to evaluate the pulmonary function in subjects with diagnosis of Turner Syndrome, in charge at the Syndromology Ward of the Paediatric Clinic of S.Orsola-Malpighi hospital. There are very few datas about lung function in patients with Turner syndrome’s genotype and phenotype in medical literature. Since the thorax of these subjects have peculiar anatomic shape (as “shield” or “overturned triangle”), we presupposed that these subjects could have also a peculiar respiratory function. Moreover we look for the possibility of correlation between pulmonary function and estroprogestinic replacement therapy and/or growth hormone (GH) replacement therapy. Material and methods: we studied 48 patients, with diagnosis of Turner Syndrome; they all made spirometry voluntarily and, when capable, also plethismografy. Results: - the parametres of pulmonary function are a little higher of the predicted values for age and sex but they are a little lower if they're corrected for each patient’s ideal high and weight: so we can conclude that in Turner Syndrme subjects pulmonary function is normal; -there’s not a statistically significant correlation between pulmonary function and GH therapy; -there’s not a statistically significant correlation between GH therapy’s length and pulmonary function except for Total Lung Capacity which increases with the number of years of GH therapy; - there’s not a statistically significant correlation between pulmonary function and estroprogestinic replacement herapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this thesis we describe in detail the Monte Carlo simulation (LVDG4) built to interpret the experimental data collected by LVD and to measure the muon-induced neutron yield in iron and liquid scintillator. A full Monte Carlo simulation, based on the Geant4 (v 9.3) toolkit, has been developed and validation tests have been performed. We used the LVDG4 to determine the active vetoing and the shielding power of LVD. The idea was to evaluate the feasibility to host a dark matter detector in the most internal part, called Core Facility (LVD-CF). The first conclusion is that LVD is a good moderator, but the iron supporting structure produce a great number of neutrons near the core. The second conclusions is that if LVD is used as an active veto for muons, the neutron flux in the LVD-CF is reduced by a factor 50, of the same order of magnitude of the neutron flux in the deepest laboratory of the world, Sudbury. Finally, the muon-induced neutron yield has been measured. In liquid scintillator we found $(3.2 \pm 0.2) \times 10^{-4}$ n/g/cm$^2$, in agreement with previous measurements performed at different depths and with the general trend predicted by theoretical calculations and Monte Carlo simulations. Moreover we present the first measurement, in our knowledge, of the neutron yield in iron: $(1.9 \pm 0.1) \times 10^{-3}$ n/g/cm$^2$. That measurement provides an important check for the MC of neutron production in heavy materials that are often used as shield in low background experiments.