7 resultados para Radiation dose reduction

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Plasma Focus is a device designed to generate a plasma sheet between two coaxial electrodes by means of a high voltage difference. The plasma is then driven to collapse into a “pinch”, where thermonuclear conditions prevail. During the “pinch phase” charged particles are emitted, with two main components: an ion beam peaked forward and an electron beam directed backward. The electron beam emitted backward by Plasma Focus devices is being investigated as a radiation source for medical applications, using it to produce x-rays by interaction with appropriate targets (through bremsstrahlung and characteristic emission). A dedicated Plasma Focus device, named PFMA-3 (Plasma Focus for Medical Applications number 3), has been designed, put in operation and tested by the research groups of the Universities of Bologna and Ferrara. The very high dose rate (several gray per discharge, in less than 1 µs) is a peculiarity of this device that has to be investigated, as it might modify the relative biological effectiveness (RBE). Aim of this Ph.D. project was to investigate the main physical properties of the low-energy x-ray beams produced by a Plasma Focus device and their potential medical applications to IORT treatments. It was necessary to develop the optimal geometrical configuration; to evaluate the x-rays produced and their dose deposited; to estimate the energy electron spectrum produced in the “pinch phase”; to study an optimal target for the conversion of the x-rays; to conduct simulations to study the physics involved; and in order to evaluate the radio-biological features of the beam, cell holders had to be developed for both irradiations and cell growth conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tanchirasi (TNKS) è un membro della superfamiglia delle PARP (Poli ADP-Ribosio Polimerasi). TNKS è coinvolta nella stabilizzazione della subunità catalitca del complesso proteico DNA-PK (protein chinasi DNA-dipendente), la DNA-PKcs. Questa proteina è fondamentale per il corretto funzionamento del meccanismo di riparo del DNA chiamato "Saldatura Non Omologa delle Estremità" (NHEJ). La deplezione di TNKS induce una degradazione della DNA-PKcs e una maggiore sensibilità alle radiazioni ionizzanti (RI). TNKS è inoltre un regolatore negativo di axina e di conseguenza un attivatore del pathway di WNT; l'inibizione quindi di TNKS induce anche una inibizione del pathway di WNT. Alterazioni in questo signalling si riscontrano frequentemente nel Medulloblastoma (MB), il tumore cerebrale embrionale più comune dell'infanzia. La radioterapia post-operatoria risulta essere molto efficacia in questa neoplasia, ma causa gravi effetti collaterali e un terzo dei pazienti presenta radioresistenza intrinseca. Un'importante sfida per la ricerca è quindi l'aumento della radiosensibilità tumorale. In questo lavoro, abbiamo studiato gli effetti dell'inibizione farmacologica di TNKS in linee cellulari di MB umano, mediante la small molecule XAV939, potente e specifico inibitore di TNKS. Il trattamento con XAV939 induce una consistente inibizione della capacità proliferativa e clonogenica, non correlata ad un aumento della mortalità cellulare, indicando una bassa tossicità legata alla molecola. Il co-trattamento di XAV939 e RI (γ-ray, dose 2 Gy) causa una ulteriore inibizione della proliferazione cellulare e della capacità di formare colonie. Abbiamo inoltre constatato, mediante Neutral Comet Assay, una minore efficacia nel riparo del DNA in cellule irradiate trattate con XAV939, indicando un effettivo aumento della radiosensibilità in cellule di MB trattate con l'inibitore di TNKS. L'aumentata mortalità cellulare in cellule tumorali trattate con XAV939 e RI ha confermato la nostra ipotesi. Il nostro studio in vitro indica come TNKS possa essere un utile target terapeutico per rendere più efficace l'attuale terapia contro il MB.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work is to present various aspects of numerical simulation of particle and radiation transport for industrial and environmental protection applications, to enable the analysis of complex physical processes in a fast, reliable, and efficient way. In the first part we deal with speed-up of numerical simulation of neutron transport for nuclear reactor core analysis. The convergence properties of the source iteration scheme of the Method of Characteristics applied to be heterogeneous structured geometries has been enhanced by means of Boundary Projection Acceleration, enabling the study of 2D and 3D geometries with transport theory without spatial homogenization. The computational performances have been verified with the C5G7 2D and 3D benchmarks, showing a sensible reduction of iterations and CPU time. The second part is devoted to the study of temperature-dependent elastic scattering of neutrons for heavy isotopes near to the thermal zone. A numerical computation of the Doppler convolution of the elastic scattering kernel based on the gas model is presented, for a general energy dependent cross section and scattering law in the center of mass system. The range of integration has been optimized employing a numerical cutoff, allowing a faster numerical evaluation of the convolution integral. Legendre moments of the transfer kernel are subsequently obtained by direct quadrature and a numerical analysis of the convergence is presented. In the third part we focus our attention to remote sensing applications of radiative transfer employed to investigate the Earth's cryosphere. The photon transport equation is applied to simulate reflectivity of glaciers varying the age of the layer of snow or ice, its thickness, the presence or not other underlying layers, the degree of dust included in the snow, creating a framework able to decipher spectral signals collected by orbiting detectors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, the well-known MC code FLUKA was used to simulate the GE PETrace cyclotron (16.5 MeV) installed at “S. Orsola-Malpighi” University Hospital (Bologna, IT) and routinely used in the production of positron emitting radionuclides. Simulations yielded estimates of various quantities of interest, including: the effective dose distribution around the equipment; the effective number of neutron produced per incident proton and their spectral distribution; the activation of the structure of the cyclotron and the vault walls; the activation of the ambient air, in particular the production of 41Ar, the assessment of the saturation yield of radionuclides used in nuclear medicine. The simulations were validated against experimental measurements in terms of physical and transport parameters to be used at the energy range of interest in the medical field. The validated model was also extensively used in several practical applications uncluding the direct cyclotron production of non-standard radionuclides such as 99mTc, the production of medical radionuclides at TRIUMF (Vancouver, CA) TR13 cyclotron (13 MeV), the complete design of the new PET facility of “Sacro Cuore – Don Calabria” Hospital (Negrar, IT), including the ACSI TR19 (19 MeV) cyclotron, the dose field around the energy selection system (degrader) of a proton therapy cyclotron, the design of plug-doors for a new cyclotron facility, in which a 70 MeV cyclotron will be installed, and the partial decommissioning of a PET facility, including the replacement of a Scanditronix MC17 cyclotron with a new TR19 cyclotron.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Proton radiation therapy is a form of external radiation that uses charged particles which have distinct physical advantages to deliver the majority of its dose in the target while minimizing the dose of radiation to normal tissues. In children who are particularly susceptible even at low and medium doses of radiation, the significant reduction of integral dose can potentially mitigate the incidence of side effects and improve quality of life. The aim of the first part of the thesis is to describe the physical and radiobiological properties of protons, the Proton Therapy Center of Trento (TCPT) active for clinical purpose since 2014, which use the most recent technique called active pencil beam scanning. The second part of the thesis describes the preliminary clinical results of 23 pediatric patients with central nervous system tumors as well as of two aggressive pediatric meningiomas treated with pencil beam scanning. All the patients were particularly well-suited candidates for proton therapy (PT) for possible benefits in terms of survival and incidence of acute and late side effects. We reported also a multicentric experience of 27 medulloblastoma patients (median age 6 years, M/F ratio 13/14) treated between 2015 and 2020 at TPTC coming from three Pediatric oncology centers: Bologna, Florence, and Ljubljana, with a focus on clinical results and toxicities related to radiotherapy (RT). Proton therapy was associated with mostly mild acute and late adverse effects and no cases of CNS necrosis or high grade of neuroradiological abnormailities. Comparable rates of survival and local control were obtained to those achievable with conventional RT. Finally, we performed a systematic review to specifically address the safety of PT for pediatric CNS patients, late side effects and clinical effectiveness after PT in this patient group.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A Plasma Focus device can confine in a small region a plasma generated during the pinch phase. When the plasma is in the pinch condition it creates an environment that produces several kinds of radiations. When the filling gas is nitrogen, a self-collimated backwardly emitted electron beam, slightly spread by the coulomb repulsion, can be considered one of the most interesting outputs. That beam can be converted into X-ray pulses able to transfer energy at an Ultra-High Dose-Rate (UH-DR), up to 1 Gy pulse-1, for clinical applications, research, or industrial purposes. The radiation fields have been studied with the PFMA-3 hosted at the University of Bologna, finding the radiation behavior at different operating conditions and working parameters for a proper tuning of this class of devices in clinical applications. The experimental outcomes have been compared with available analytical formalisms as benchmark and the scaling laws have been proposed. A set of Monte Carlo models have been built with direct and adjoint techniques for an accurate X-ray source characterization and for setting fast and reliable irradiation planning for patients. By coupling deterministic and Monte Carlo codes, a focusing lens for the charged particles has been designed for obtaining a beam suitable for applications as external radiotherapy or intra-operative radiation therapy. The radiobiological effectiveness of the UH PF DR, a FLASH source, has been evaluated by coupling different Monte Carlo codes estimating the overall level of DNA damage at the multi-cellular and tissue levels by considering the spatial variation effects as well as the radiation field characteristics. The numerical results have been correlated to the experimental outcomes. Finally, ambient dose measurements have been performed for tuning the numerical models and obtaining doses for radiation protection purposes. The PFMA-3 technology has been fully characterized toward clinical implementation and installation in a medical facility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ionizing radiations are important tools employed every day in the modern society. For example, in medicine they are routinely used for diagnostic and therapy. The large variety of applications leads to the need of novel, more efficient, low-cost ionizing radiation detectors with new functionalities. Personal dosimetry would benefit from wearable detectors able to conform to the body surfaces. Traditional semiconductors used for ionizing radiation direct detectors offer high performance but they are intrinsically stiff, brittle and require high voltages to operate. Hybrid lead-halide perovskites emerged recently as a novel class of materials for ionizing radiation detection. They combine high absorption coefficient, solution processability and high charge transport capability, enabling efficient and low-cost detection. The deposition from solution allows the fabrication of thin-film flexible devices. In this thesis, I studied the detection properties of different types of hybrid perovskites, deposited from solution in thin-film form, and tested under X-rays, gamma-rays and protons beams. I developed the first ultraflexible X-ray detector with exceptional conformability. The effect of coupling organic layers with perovskites was studied at the nanoscale giving a direct demonstration of trap passivation effect at the grain boundaries. Different perovskite formulations were deposited and tested to improve the film stability. I report about the longest aging studies on perovskite X-ray detectors showing that the addition of starch in the precursors’ solution can improve the stability in time with only a 7% decrease in sensitivity after 630 days of storage in ambient conditions. 2D perovskites were also explored as direct detector for X-rays and gamma-rays. Detection of 511 keV photons by a thin-film device is here demonstrated and was validated for monitoring a radiotracer injection. At last, a new approach has been used: a 2D/3Dmixed perovskite thin-film demonstrated to reliably detect 5 MeV protons, envisioning wearable dose monitoring during proton/hadron therapy treatments.