3 resultados para RECALIBRATION

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Human brain is provided with a flexible audio-visual system, which interprets and guides responses to external events according to spatial alignment, temporal synchronization and effectiveness of unimodal signals. The aim of the present thesis was to explore the possibility that such a system might represent the neural correlate of sensory compensation after a damage to one sensory pathway. To this purpose, three experimental studies have been conducted, which addressed the immediate, short-term and long-term effects of audio-visual integration on patients with Visual Field Defect (VFD). Experiment 1 investigated whether the integration of stimuli from different modalities (cross-modal) and from the same modality (within-modal) have a different, immediate effect on localization behaviour. Patients had to localize modality-specific stimuli (visual or auditory), cross-modal stimulus pairs (visual-auditory) and within-modal stimulus pairs (visual-visual). Results showed that cross-modal stimuli evoked a greater improvement than within modal stimuli, consistent with a Bayesian explanation. Moreover, even when visual processing was impaired, cross-modal stimuli improved performance in an optimal fashion. These findings support the hypothesis that the improvement derived from multisensory integration is not attributable to simple target redundancy, and prove that optimal integration of cross-modal signals occurs in processing stage which are not consciously accessible. Experiment 2 examined the possibility to induce a short term improvement of localization performance without an explicit knowledge of visual stimulus. Patients with VFD and patients with neglect had to localize weak sounds before and after a brief exposure to a passive cross-modal stimulation, which comprised spatially disparate or spatially coincident audio-visual stimuli. After exposure to spatially disparate stimuli in the affected field, only patients with neglect exhibited a shifts of auditory localization toward the visual attractor (the so called Ventriloquism After-Effect). In contrast, after adaptation to spatially coincident stimuli, both neglect and hemianopic patients exhibited a significant improvement of auditory localization, proving the occurrence of After Effect for multisensory enhancement. These results suggest the presence of two distinct recalibration mechanisms, each mediated by a different neural route: a geniculo-striate circuit and a colliculus-extrastriate circuit respectively. Finally, Experiment 3 verified whether a systematic audio-visual stimulation could exert a long-lasting effect on patients’ oculomotor behaviour. Eye movements responses during a visual search task and a reading task were studied before and after visual (control) or audio-visual (experimental) training, in a group of twelve patients with VFD and twelve controls subjects. Results showed that prior to treatment, patients’ performance was significantly different from that of controls in relation to fixations and saccade parameters; after audiovisual training, all patients reported an improvement in ocular exploration characterized by fewer fixations and refixations, quicker and larger saccades, and reduced scanpath length. Similarly, reading parameters were significantly affected by the training, with respect to specific impairments observed in left and right hemisphere–damaged patients. The present findings provide evidence that a systematic audio-visual stimulation may encourage a more organized pattern of visual exploration with long lasting effects. In conclusion, results from these studies clearly demonstrate that the beneficial effects of audio-visual integration can be retained in absence of explicit processing of visual stimulus. Surprisingly, an improvement of spatial orienting can be obtained not only when a on-line response is required, but also after either a brief or a long adaptation to audio-visual stimulus pairs, so suggesting the maintenance of mechanisms subserving cross-modal perceptual learning after a damage to geniculo-striate pathway. The colliculus-extrastriate pathway, which is spared in patients with VFD, seems to play a pivotal role in this sensory compensation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective of this work was to investigate the impact of different hybridization concepts and levels of hybridization on fuel economy of a standard road vehicle where both conventional and non-conventional hybrid architectures are treated exactly in the same way from the point of view of overall energy flow optimization. Hybrid component models were developed and presented in detail as well as the simulations results mainly for NEDC cycle. The analysis was performed on four different parallel hybrid powertrain concepts: Hybrid Electric Vehicle (HEV), High Speed Flywheel Hybrid Vehicle (HSF-HV), Hydraulic Hybrid Vehicle (HHV) and Pneumatic Hybrid Vehicle (PHV). In order to perform equitable analysis of different hybrid systems, comparison was performed also on the basis of the same usable system energy storage capacity (i.e. 625kJ for HEV, HSF and the HHV) but in the case of pneumatic hybrid systems maximal storage capacity was limited by the size of the systems in order to comply with the packaging requirements of the vehicle. The simulations were performed within the IAV Gmbh - VeLoDyn software simulator based on Matlab / Simulink software package. Advanced cycle independent control strategy (ECMS) was implemented into the hybrid supervisory control unit in order to solve power management problem for all hybrid powertrain solutions. In order to maintain State of Charge within desired boundaries during different cycles and to facilitate easy implementation and recalibration of the control strategy for very different hybrid systems, Charge Sustaining Algorithm was added into the ECMS framework. Also, a Variable Shift Pattern VSP-ECMS algorithm was proposed as an extension of ECMS capabilities so as to include gear selection into the determination of minimal (energy) cost function of the hybrid system. Further, cycle-based energetic analysis was performed in all the simulated cases, and the results have been reported in the corresponding chapters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis aimed at addressing some of the issues that, at the state of the art, avoid the P300-based brain computer interface (BCI) systems to move from research laboratories to end users’ home. An innovative asynchronous classifier has been defined and validated. It relies on the introduction of a set of thresholds in the classifier, and such thresholds have been assessed considering the distributions of score values relating to target, non-target stimuli and epochs of voluntary no-control. With the asynchronous classifier, a P300-based BCI system can adapt its speed to the current state of the user and can automatically suspend the control when the user diverts his attention from the stimulation interface. Since EEG signals are non-stationary and show inherent variability, in order to make long-term use of BCI possible, it is important to track changes in ongoing EEG activity and to adapt BCI model parameters accordingly. To this aim, the asynchronous classifier has been subsequently improved by introducing a self-calibration algorithm for the continuous and unsupervised recalibration of the subjective control parameters. Finally an index for the online monitoring of the EEG quality has been defined and validated in order to detect potential problems and system failures. This thesis ends with the description of a translational work involving end users (people with amyotrophic lateral sclerosis-ALS). Focusing on the concepts of the user centered design approach, the phases relating to the design, the development and the validation of an innovative assistive device have been described. The proposed assistive technology (AT) has been specifically designed to meet the needs of people with ALS during the different phases of the disease (i.e. the degree of motor abilities impairment). Indeed, the AT can be accessed with several input devices either conventional (mouse, touchscreen) or alterative (switches, headtracker) up to a P300-based BCI.