Resumo:
Knowledge on how ligaments and articular surfaces guide passive motion at the human ankle joint complex is fundamental for the design of relevant surgical treatments. The dissertation presents a possible improvement of this knowledge by a new kinematic model of the tibiotalar articulation. In this dissertation two one-DOF spatial equivalent mechanisms are presented for the simulation of the passive motion of the human ankle joint: the 5-5 fully parallel mechanism and the fully parallel spherical wrist mechanism. These mechanisms are based on the main anatomical structures of the ankle joint, namely the talus/calcaneus and the tibio/fibula bones at their interface, and the TiCaL and CaFiL ligaments. In order to show the accuracy of the models and the efficiency of the proposed procedure, these mechanisms are synthesized from experimental data and the results are compared with those obtained both during experimental sessions and with data published in the literature. Experimental results proved the efficiency of the proposed new mechanisms to simulate the ankle passive motion and, at the same time, the potentiality of the mechanism to replicate the ankle’s main anatomical structures quite well. The new mechanisms represent a powerful tool for both pre-operation planning and new prosthesis design.
Resumo:
Total ankle arthroplasty (TAA) is still not as satisfactory as total hip and total knee arthroplasty. For the TAA to be considered a valuable alternative to ankle arthrodesis, an effective range of ankle mobility must be recovered. The disappointing clinical results of the current generation of TAA are mostly related to poor understanding of the structures guiding ankle joint mobility. A new design (BOX Ankle) has been developed, uniquely able to restore physiologic ankle mobility and a natural relationship between the implanted components and the retained ligaments. For the first time the shapes of the tibial and talar components in the sagittal plane were designed to be compatible with the demonstrated ligament isometric rotation. This resulted in an unique motion at the replaced ankle where natural sliding as well as rolling motion occurs while at the same time full conformity is maintained between the three components throughout the flexion arc. According to prior research, the design features a spherical convex tibial component, a talar component with radius of curvature in the sagittal plane longer than that of the natural talus, and a fully conforming meniscal component. After computer-based modelling and preliminary observations in several trial implantation in specimens, 126 patients were implanted in the period July 2003 – December 2008. 75 patients with at least 6 months follow-up are here reported. Mean age was 62,6 years (range 22 – 80), mean follow-up 20,2 months. The AOFAS clinical score systems were used to assess patient outcome. Radiographs at maximal dorsiflexion and maximal plantar flexion confirmed the meniscalbearing component moves anteriorly during dorsiflexion and posteriorly during plantarflexion. Frontal and lateral radiographs in the patients, show good alignment of the components, and no signs of radiolucency or loosening. The mean AOFAS score was observed to go from 41 pre-op to 74,6 at 6 month follow-up, with further improvement at the following follow-up. These early results reveal satisfactory clinical scores, with good recovery of range of motion and reduction of pain. Radiographic assessment reveals good osteointegration. All these preliminary results confirm biomechanical studies and the validity of this novel ligamentcompatible prosthesis design. Surely it will be important to re-evaluate these patients later.
Resumo:
Background. The surgical treatment of dysfunctional hips is a severe condition for the patient and a costly therapy for the public health. Hip resurfacing techniques seem to hold the promise of various advantages over traditional THR, with particular attention to young and active patients. Although the lesson provided in the past by many branches of engineering is that success in designing competitive products can be achieved only by predicting the possible scenario of failure, to date the understanding of the implant quality is poorly pre-clinically addressed. Thus revision is the only delayed and reliable end point for assessment. The aim of the present work was to model the musculoskeletal system so as to develop a protocol for predicting failure of hip resurfacing prosthesis. Methods. Preliminary studies validated the technique for the generation of subject specific finite element (FE) models of long bones from Computed Thomography data. The proposed protocol consisted in the numerical analysis of the prosthesis biomechanics by deterministic and statistic studies so as to assess the risk of biomechanical failure on the different operative conditions the implant might face in a population of interest during various activities of daily living. Physiological conditions were defined including the variability of the anatomy, bone densitometry, surgery uncertainties and published boundary conditions at the hip. The protocol was tested by analysing a successful design on the market and a new prototype of a resurfacing prosthesis. Results. The intrinsic accuracy of models on bone stress predictions (RMSE < 10%) was aligned to the current state of the art in this field. The accuracy of prediction on the bone-prosthesis contact mechanics was also excellent (< 0.001 mm). The sensitivity of models prediction to uncertainties on modelling parameter was found below 8.4%. The analysis of the successful design resulted in a very good agreement with published retrospective studies. The geometry optimisation of the new prototype lead to a final design with a low risk of failure. The statistical analysis confirmed the minimal risk of the optimised design over the entire population of interest. The performances of the optimised design showed a significant improvement with respect to the first prototype (+35%). Limitations. On the authors opinion the major limitation of this study is on boundary conditions. The muscular forces and the hip joint reaction were derived from the few data available in the literature, which can be considered significant but hardly representative of the entire variability of boundary conditions the implant might face over the patients population. This moved the focus of the research on modelling the musculoskeletal system; the ongoing activity is to develop subject-specific musculoskeletal models of the lower limb from medical images. Conclusions. The developed protocol was able to accurately predict known clinical outcomes when applied to a well-established device and, to support the design optimisation phase providing important information on critical characteristics of the patients when applied to a new prosthesis. The presented approach does have a relevant generality that would allow the extension of the protocol to a large set of orthopaedic scenarios with minor changes. Hence, a failure mode analysis criterion can be considered a suitable tool in developing new orthopaedic devices.