4 resultados para PV inverter

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new conversion structure for three-phase grid-connected photovoltaic (PV) generation plants is presented and discussed in this Thesis. The conversion scheme is based on two insulated PV arrays, each one feeding the dc bus of a standard 2-level three-phase voltage source inverter (VSI). Inverters are connected to the grid by a traditional three-phase transformer having open-end windings at inverters side and either star or delta connection at the grid side. The resulting conversion structure is able to perform as a multilevel VSI, equivalent to a 3-level inverter, doubling the power capability of a single VSI with given voltage and current ratings. Different modulation schemes able to generate proper multilevel voltage waveforms have been discussed and compared. They include known algorithms, some their developments, and new original approaches. The goal was to share the grid power with a given ratio between the two VSI within each cycle period of the PWM, being the PWM pattern suitable for the implementation in industrial DSPs. It has been shown that an extension of the modulation methods for standard two-level inverter can provide a elegant solution for dual two-level inverter. An original control method has been introduced to regulate the dc-link voltages of each VSI, according to the voltage reference given by a single MPPT controller. A particular MPPT algorithm has been successfully tested, based on the comparison of the operating points of the two PV arrays. The small deliberately introduced difference between two operating dc voltages leads towards the MPP in a fast and accurate manner. Either simulation or experimental tests, or even both, always accompanied theoretical developments. For the simulation, the Simulink tool of Matlab has been adopted, whereas the experiments have been carried out by a full-scale low-voltage prototype of the whole PV generation system. All the research work was done at the Lab of the Department of Electrical Engineering, University of Bologna.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research work carried out in focusing a novel multiphase-multilevel ac motor drive system much suitable for low-voltage high-current power applications. In specific, six-phase asymmetrical induction motor with open-end stator winding configuration, fed from four standard two-level three-phase voltage source inverters (VSIs). Proposed synchronous reference frame control algorithm shares the total dc source power among the 4 VSIs in each switching cycle with three degree of freedom. Precisely, first degree of freedom concerns with the current sharing between two three-phase stator windings. Based on modified multilevel space vector pulse width modulation shares the voltage between each single VSIs of two three-phase stator windings with second and third degree of freedom, having proper multilevel output waveforms. Complete model of whole ac motor drive based on three-phase space vector decomposition approach was developed in PLECS - numerical simulation software working in MATLAB environment. Proposed synchronous reference control algorithm was framed in MATLAB with modified multilevel space vector pulse width modulator. The effectiveness of the entire ac motor drives system was tested. Simulation results are given in detail to show symmetrical and asymmetrical, power sharing conditions. Furthermore, the three degree of freedom are exploited to investigate fault tolerant capabilities in post-fault conditions. Complete set of simulation results are provided when one, two and three VSIs are faulty. Hardware prototype model of quad-inverter was implemented with two passive three-phase open-winding loads using two TMS320F2812 DSP controllers. Developed McBSP (multi-channel buffered serial port) communication algorithm able to control the four VSIs for PWM communication and synchronization. Open-loop control scheme based on inverse three-phase decomposition approach was developed to control entire quad-inverter configuration and tested with balanced and unbalanced operating conditions with simplified PWM techniques. Both simulation and experimental results are always in good agreement with theoretical developments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Il cancro batterico dell’actinidia causato da Pseudomonas syringae pv.actinidiae (Psa) suscita grande interesse a livello globale a partire dal 2008. La malattia è comparsa in Giappone e in due anni ha avuto una diffusione epidemica in tutte le aree di coltivazione mondiale di actinidia. Gravi perdite economiche hanno attirato l’attenzione internazionale su questa problematica e grandi sforzi sono stati rivolti allo studio di questo patosistema ancora poco conosciuto. E’ emerso infatti che il patogeno può rimanere in fase latente per lunghi periodi senza causare sintomi caratteristici nelle piante infette, e che dalla comparsa dei sintomi la pianta muore nell’arco di un paio d’anni. Il monitoraggio ed il controllo della situazione è perciò di fondamentale importanza ed è ancora più importante prevenire la comparsa di nuovi focolai di infezione. A questo proposito sarebbe opportuno l’impiego di materiale vegetale di propagazione non infetto, ma in molti casi questo diventa difficile, dal momento che il materiale impiegato è generalmente quello asintomatico, non analizzato precedentemente per la presenza del patogeno. Negli ultimi anni sono state perciò messe a punto molte tecniche molecolari per l’identificazione di Psa direttamente da materiale vegetale. L’obiettivo di questo lavoro è stato quello di studiare l’epidemiologia di Psa in piante adulte infette e di verificare l’efficacia di metodi di diagnosi precoce per prevenire la malattia. A tale scopo il lavoro sperimentale è stato suddiviso in diverse fasi: i) studio della localizzazione, traslocazione e sopravvivenza di Psa nelle piante, a seguito di inoculazione in piante adulte di actinidia di ceppi marcati Psa::gfp; ii) studio della capacità di Psa di essere mantenuto in germogli di actinidia attraverso sette generazioni di micropropagazione dopo l’inoculazione delle piante madri con lo stesso ceppo marcato Psa::gfp; iii) studio ed applicazioni di un nuovo metodo di diagnosi precoce di Psa basato sull’analisi molecolare del “pianto”.