13 resultados para Monolithic Coupler
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
Computer aided design of Monolithic Microwave Integrated Circuits (MMICs) depends critically on active device models that are accurate, computationally efficient, and easily extracted from measurements or device simulators. Empirical models of active electron devices, which are based on actual device measurements, do not provide a detailed description of the electron device physics. However they are numerically efficient and quite accurate. These characteristics make them very suitable for MMIC design in the framework of commercially available CAD tools. In the empirical model formulation it is very important to separate linear memory effects (parasitic effects) from the nonlinear effects (intrinsic effects). Thus an empirical active device model is generally described by an extrinsic linear part which accounts for the parasitic passive structures connecting the nonlinear intrinsic electron device to the external world. An important task circuit designers deal with is evaluating the ultimate potential of a device for specific applications. In fact once the technology has been selected, the designer would choose the best device for the particular application and the best device for the different blocks composing the overall MMIC. Thus in order to accurately reproducing the behaviour of different-in-size devices, good scalability properties of the model are necessarily required. Another important aspect of empirical modelling of electron devices is the mathematical (or equivalent circuit) description of the nonlinearities inherently associated with the intrinsic device. Once the model has been defined, the proper measurements for the characterization of the device are performed in order to identify the model. Hence, the correct measurement of the device nonlinear characteristics (in the device characterization phase) and their reconstruction (in the identification or even simulation phase) are two of the more important aspects of empirical modelling. This thesis presents an original contribution to nonlinear electron device empirical modelling treating the issues of model scalability and reconstruction of the device nonlinear characteristics. The scalability of an empirical model strictly depends on the scalability of the linear extrinsic parasitic network, which should possibly maintain the link between technological process parameters and the corresponding device electrical response. Since lumped parasitic networks, together with simple linear scaling rules, cannot provide accurate scalable models, either complicate technology-dependent scaling rules or computationally inefficient distributed models are available in literature. This thesis shows how the above mentioned problems can be avoided through the use of commercially available electromagnetic (EM) simulators. They enable the actual device geometry and material stratification, as well as losses in the dielectrics and electrodes, to be taken into account for any given device structure and size, providing an accurate description of the parasitic effects which occur in the device passive structure. It is shown how the electron device behaviour can be described as an equivalent two-port intrinsic nonlinear block connected to a linear distributed four-port passive parasitic network, which is identified by means of the EM simulation of the device layout, allowing for better frequency extrapolation and scalability properties than conventional empirical models. Concerning the issue of the reconstruction of the nonlinear electron device characteristics, a data approximation algorithm has been developed for the exploitation in the framework of empirical table look-up nonlinear models. Such an approach is based on the strong analogy between timedomain signal reconstruction from a set of samples and the continuous approximation of device nonlinear characteristics on the basis of a finite grid of measurements. According to this criterion, nonlinear empirical device modelling can be carried out by using, in the sampled voltage domain, typical methods of the time-domain sampling theory.
Resumo:
Finite element techniques for solving the problem of fluid-structure interaction of an elastic solid material in a laminar incompressible viscous flow are described. The mathematical problem consists of the Navier-Stokes equations in the Arbitrary Lagrangian-Eulerian formulation coupled with a non-linear structure model, considering the problem as one continuum. The coupling between the structure and the fluid is enforced inside a monolithic framework which computes simultaneously for the fluid and the structure unknowns within a unique solver. We used the well-known Crouzeix-Raviart finite element pair for discretization in space and the method of lines for discretization in time. A stability result using the Backward-Euler time-stepping scheme for both fluid and solid part and the finite element method for the space discretization has been proved. The resulting linear system has been solved by multilevel domain decomposition techniques. Our strategy is to solve several local subproblems over subdomain patches using the Schur-complement or GMRES smoother within a multigrid iterative solver. For validation and evaluation of the accuracy of the proposed methodology, we present corresponding results for a set of two FSI benchmark configurations which describe the self-induced elastic deformation of a beam attached to a cylinder in a laminar channel flow, allowing stationary as well as periodically oscillating deformations, and for a benchmark proposed by COMSOL multiphysics where a narrow vertical structure attached to the bottom wall of a channel bends under the force due to both viscous drag and pressure. Then, as an example of fluid-structure interaction in biomedical problems, we considered the academic numerical test which consists in simulating the pressure wave propagation through a straight compliant vessel. All the tests show the applicability and the numerical efficiency of our approach to both two-dimensional and three-dimensional problems.
Resumo:
We have realized a Data Acquisition chain for the use and characterization of APSEL4D, a 32 x 128 Monolithic Active Pixel Sensor, developed as a prototype for frontier experiments in high energy particle physics. In particular a transition board was realized for the conversion between the chip and the FPGA voltage levels and for the signal quality enhancing. A Xilinx Spartan-3 FPGA was used for real time data processing, for the chip control and the communication with a Personal Computer through a 2.0 USB port. For this purpose a firmware code, developed in VHDL language, was written. Finally a Graphical User Interface for the online system monitoring, hit display and chip control, based on windows and widgets, was realized developing a C++ code and using Qt and Qwt dedicated libraries. APSEL4D and the full acquisition chain were characterized for the first time with the electron beam of the transmission electron microscope and with 55Fe and 90Sr radioactive sources. In addition, a beam test was performed at the T9 station of the CERN PS, where hadrons of momentum of 12 GeV/c are available. The very high time resolution of APSEL4D (up to 2.5 Mfps, but used at 6 kfps) was fundamental in realizing a single electron Young experiment using nanometric double slits obtained by a FIB technique. On high statistical samples, it was possible to observe the interference and diffractions of single isolated electrons traveling inside a transmission electron microscope. For the first time, the information on the distribution of the arrival time of the single electrons has been extracted.
Resumo:
This PhD thesis has been proposed to validate and then apply innovative analytical methodologies for the determination of compounds with harmful impact on human health, such as biogenic amines and ochratoxin A in wines. Therefore, the influence of production technology (pH, amino acids precursor and use of different malolactic starters) on biogenic amines content in wines was evaluated. An HPLC method for simultaneous determination of amino acids and amines with precolumnderivatization with 9-Fluorenyl-methoxycarbonyl chloride (FMOC-Cl) and UV detection was developed. Initially, the influence of pH, time of derivatization, gradient profile were studied. In order to improve the separation of amino acids and amines and reduce the time of analysis, it was decided to study the influence of different flows and the use of different columns in the chromatographic method. Firstly, a C18 Luna column was used and later two monolithic columns Chromolith in series. It appeared to be suitable for an easy, precise and accurate determination of a relatively large number of amino acids and amines in wines. This method was then applied on different wines produced in the Emilia Romagna region. The investigation permitted to discriminate between red and white wines. Amino acids content is related to the winemaking process. Biogenic amines content in these wines does not represent a possible toxicological problem for human health. The results of the study of influence of technologies and wine composition demonstrated that pH of wines and amino acids content are the most important factors. Particularly wines with pH > 3,5 show higher concentration of biogenic amines than wines with lower pH. The enrichment of wines by nutrients also influences the content of some biogenic amines that are higher in wines added with amino acids precursors. In this study, amino acids and biogenic amines are not statistically affected by strain of lactic acid bacteria inoculated as a starter for malolactic fermentation. An evaluation of different clean-up (SPE-MycoSep; IACs and LLE) and determination methods (HPLC and ELISA) of ochratoxin A was carried out. The results obtained proved that the SPE clean-up are reliable at the same level while the LLE procedures shows lowest recovery. The ELISA method gave a lower determination and a low reproducibility than HPLC method.
Resumo:
Negli ultimi anni, un crescente numero di studiosi ha focalizzato la propria attenzione sullo sviluppo di strategie che permettessero di caratterizzare le proprietà ADMET dei farmaci in via di sviluppo, il più rapidamente possibile. Questa tendenza origina dalla consapevolezza che circa la metà dei farmaci in via di sviluppo non viene commercializzato perché ha carenze nelle caratteristiche ADME, e che almeno la metà delle molecole che riescono ad essere commercializzate, hanno comunque qualche problema tossicologico o ADME [1]. Infatti, poco importa quanto una molecola possa essere attiva o specifica: perché possa diventare farmaco è necessario che venga ben assorbita, distribuita nell’organismo, metabolizzata non troppo rapidamente, ne troppo lentamente e completamente eliminata. Inoltre la molecola e i suoi metaboliti non dovrebbero essere tossici per l’organismo. Quindi è chiaro come una rapida determinazione dei parametri ADMET in fasi precoci dello sviluppo del farmaco, consenta di risparmiare tempo e denaro, permettendo di selezionare da subito i composti più promettenti e di lasciar perdere quelli con caratteristiche negative. Questa tesi si colloca in questo contesto, e mostra l’applicazione di una tecnica semplice, la biocromatografia, per caratterizzare rapidamente il legame di librerie di composti alla sieroalbumina umana (HSA). Inoltre mostra l’utilizzo di un’altra tecnica indipendente, il dicroismo circolare, che permette di studiare gli stessi sistemi farmaco-proteina, in soluzione, dando informazioni supplementari riguardo alla stereochimica del processo di legame. La HSA è la proteina più abbondante presente nel sangue. Questa proteina funziona da carrier per un gran numero di molecole, sia endogene, come ad esempio bilirubina, tiroxina, ormoni steroidei, acidi grassi, che xenobiotici. Inoltre aumenta la solubilità di molecole lipofile poco solubili in ambiente acquoso, come ad esempio i tassani. Il legame alla HSA è generalmente stereoselettivo e ad avviene a livello di siti di legame ad alta affinità. Inoltre è ben noto che la competizione tra farmaci o tra un farmaco e metaboliti endogeni, possa variare in maniera significativa la loro frazione libera, modificandone l’attività e la tossicità. Per queste sue proprietà la HSA può influenzare sia le proprietà farmacocinetiche che farmacodinamiche dei farmaci. Non è inusuale che un intero progetto di sviluppo di un farmaco possa venire abbandonato a causa di un’affinità troppo elevata alla HSA, o a un tempo di emivita troppo corto, o a una scarsa distribuzione dovuta ad un debole legame alla HSA. Dal punto di vista farmacocinetico, quindi, la HSA è la proteina di trasporto del plasma più importante. Un gran numero di pubblicazioni dimostra l’affidabilità della tecnica biocromatografica nello studio dei fenomeni di bioriconoscimento tra proteine e piccole molecole [2-6]. Il mio lavoro si è focalizzato principalmente sull’uso della biocromatografia come metodo per valutare le caratteristiche di legame di alcune serie di composti di interesse farmaceutico alla HSA, e sul miglioramento di tale tecnica. Per ottenere una miglior comprensione dei meccanismi di legame delle molecole studiate, gli stessi sistemi farmaco-HSA sono stati studiati anche con il dicroismo circolare (CD). Inizialmente, la HSA è stata immobilizzata su una colonna di silice epossidica impaccata 50 x 4.6 mm di diametro interno, utilizzando una procedura precedentemente riportata in letteratura [7], con alcune piccole modifiche. In breve, l’immobilizzazione è stata effettuata ponendo a ricircolo, attraverso una colonna precedentemente impaccata, una soluzione di HSA in determinate condizioni di pH e forza ionica. La colonna è stata quindi caratterizzata per quanto riguarda la quantità di proteina correttamente immobilizzata, attraverso l’analisi frontale di L-triptofano [8]. Di seguito, sono stati iniettati in colonna alcune soluzioni raceme di molecole note legare la HSA in maniera enantioselettiva, per controllare che la procedura di immobilizzazione non avesse modificato le proprietà di legame della proteina. Dopo essere stata caratterizzata, la colonna è stata utilizzata per determinare la percentuale di legame di una piccola serie di inibitori della proteasi HIV (IPs), e per individuarne il sito(i) di legame. La percentuale di legame è stata calcolata attraverso il fattore di capacità (k) dei campioni. Questo parametro in fase acquosa è stato estrapolato linearmente dal grafico log k contro la percentuale (v/v) di 1-propanolo presente nella fase mobile. Solamente per due dei cinque composti analizzati è stato possibile misurare direttamente il valore di k in assenza di solvente organico. Tutti gli IPs analizzati hanno mostrato un’elevata percentuale di legame alla HSA: in particolare, il valore per ritonavir, lopinavir e saquinavir è risultato maggiore del 95%. Questi risultati sono in accordo con dati presenti in letteratura, ottenuti attraverso il biosensore ottico [9]. Inoltre, questi risultati sono coerenti con la significativa riduzione di attività inibitoria di questi composti osservata in presenza di HSA. Questa riduzione sembra essere maggiore per i composti che legano maggiormente la proteina [10]. Successivamente sono stati eseguiti degli studi di competizione tramite cromatografia zonale. Questo metodo prevede di utilizzare una soluzione a concentrazione nota di un competitore come fase mobile, mentre piccole quantità di analita vengono iniettate nella colonna funzionalizzata con HSA. I competitori sono stati selezionati in base al loro legame selettivo ad uno dei principali siti di legame sulla proteina. In particolare, sono stati utilizzati salicilato di sodio, ibuprofene e valproato di sodio come marker dei siti I, II e sito della bilirubina, rispettivamente. Questi studi hanno mostrato un legame indipendente dei PIs ai siti I e II, mentre è stata osservata una debole anticooperatività per il sito della bilirubina. Lo stesso sistema farmaco-proteina è stato infine investigato in soluzione attraverso l’uso del dicroismo circolare. In particolare, è stato monitorata la variazione del segnale CD indotto di un complesso equimolare [HSA]/[bilirubina], a seguito dell’aggiunta di aliquote di ritonavir, scelto come rappresentante della serie. I risultati confermano la lieve anticooperatività per il sito della bilirubina osservato precedentemente negli studi biocromatografici. Successivamente, lo stesso protocollo descritto precedentemente è stato applicato a una colonna di silice epossidica monolitica 50 x 4.6 mm, per valutare l’affidabilità del supporto monolitico per applicazioni biocromatografiche. Il supporto monolitico monolitico ha mostrato buone caratteristiche cromatografiche in termini di contropressione, efficienza e stabilità, oltre che affidabilità nella determinazione dei parametri di legame alla HSA. Questa colonna è stata utilizzata per la determinazione della percentuale di legame alla HSA di una serie di poliamminochinoni sviluppati nell’ambito di una ricerca sulla malattia di Alzheimer. Tutti i composti hanno mostrato una percentuale di legame superiore al 95%. Inoltre, è stata osservata una correlazione tra percentuale di legame è caratteristiche della catena laterale (lunghezza e numero di gruppi amminici). Successivamente sono stati effettuati studi di competizione dei composti in esame tramite il dicroismo circolare in cui è stato evidenziato un effetto anticooperativo dei poliamminochinoni ai siti I e II, mentre rispetto al sito della bilirubina il legame si è dimostrato indipendente. Le conoscenze acquisite con il supporto monolitico precedentemente descritto, sono state applicate a una colonna di silice epossidica più corta (10 x 4.6 mm). Il metodo di determinazione della percentuale di legame utilizzato negli studi precedenti si basa su dati ottenuti con più esperimenti, quindi è necessario molto tempo prima di ottenere il dato finale. L’uso di una colonna più corta permette di ridurre i tempi di ritenzione degli analiti, per cui la determinazione della percentuale di legame alla HSA diventa molto più rapida. Si passa quindi da una analisi a medio rendimento a una analisi di screening ad alto rendimento (highthroughput- screening, HTS). Inoltre, la riduzione dei tempi di analisi, permette di evitare l’uso di soventi organici nella fase mobile. Dopo aver caratterizzato la colonna da 10 mm con lo stesso metodo precedentemente descritto per le altre colonne, sono stati iniettati una serie di standard variando il flusso della fase mobile, per valutare la possibilità di utilizzare flussi elevati. La colonna è stata quindi impiegata per stimare la percentuale di legame di una serie di molecole con differenti caratteristiche chimiche. Successivamente è stata valutata la possibilità di utilizzare una colonna così corta, anche per studi di competizione, ed è stata indagato il legame di una serie di composti al sito I. Infine è stata effettuata una valutazione della stabilità della colonna in seguito ad un uso estensivo. L’uso di supporti cromatografici funzionalizzati con albumine di diversa origine (ratto, cane, guinea pig, hamster, topo, coniglio), può essere proposto come applicazione futura di queste colonne HTS. Infatti, la possibilità di ottenere informazioni del legame dei farmaci in via di sviluppo alle diverse albumine, permetterebbe un migliore paragone tra i dati ottenuti tramite esperimenti in vitro e i dati ottenuti con esperimenti sull’animale, facilitando la successiva estrapolazione all’uomo, con la velocità di un metodo HTS. Inoltre, verrebbe ridotto anche il numero di animali utilizzati nelle sperimentazioni. Alcuni lavori presenti in letteratura dimostrano l’affidabilita di colonne funzionalizzate con albumine di diversa origine [11-13]: l’utilizzo di colonne più corte potrebbe aumentarne le applicazioni.
Resumo:
Adhesive bonding provides solutions to realize cost effective and low weight aircraft fuselage structures, in particular where the Damage Tolerance (DT) is the design criterion. Bonded structures that combine Metal Laminates (MLs) and eventually Selective Reinforcements can guarantee slow crack propagation, crack arrest and large damage capability. To optimize the design exploiting the benefit of bonded structures incorporating selective reinforcement requires reliable analysis tools. The effect of bonded doublers / selective reinforcements is very difficult to be predicted numerically or analytically due to the complexity of the underlying mechanisms and failures modes acting. Reliable predictions of crack growth and residual strength can only be based on sound empirical and phenomenological considerations strictly related to the specific structural concept. Large flat stiffened panels that combine MLs and selective reinforcements have been tested with the purpose of investigating solutions applicable to pressurized fuselages. The large test campaign (for a total of 35 stiffened panels) has quantitatively investigated the role of the different metallic skin concepts (monolithic vs. MLs) of the aluminum, titanium and glass-fiber reinforcements, of the stringers material and cross sections and of the geometry and location of doublers / selective reinforcements. Bonded doublers and selective reinforcements confirmed to be outstanding tools to improve the DT properties of structural elements with a minor weight increase. However the choice of proper materials for the skin and the stringers must be not underestimated since they play an important role as well. A fuselage structural concept has been developed to exploit the benefit of a metal laminate design concept in terms of high Fatigue and Damage Tolerance (F&DT) performances. The structure used laminated skin (0.8mm thick), bonded stringers, two different splicing solutions and selective reinforcements (glass prepreg embedded in the laminate) under the circumferential frames. To validate the design concept a curved panel was manufactured and tested under loading conditions representative of a single aisle fuselage: cyclic internal pressurization plus longitudinal loads. The geometry of the panel, design and loading conditions were tailored for the requirements of the upper front fuselage. The curved panel has been fatigue tested for 60 000 cycles before the introduction of artificial damages (cracks in longitudinal and circumferential directions). The crack growth of the artificial damages has been investigated for about 85 000 cycles. At the end a residual strength test has been performed with a “2 bay over broken frame” longitudinal crack. The reparability of this innovative concept has been taken into account during design and demonstrated with the use of an external riveted repair. The F&DT curved panel test has confirmed that a long fatigue life and high damage tolerance can be achieved with a hybrid metal laminate low weight configuration. The superior fatigue life from metal laminates and the high damage tolerance characteristics provided by integrated selective reinforcements are the key concepts that provided the excellent performances. The weight comparison between the innovative bonded concept and a conventional monolithic riveted design solution showed a significant potential weight saving but the weight advantages shall be traded off with the additional costs.
Resumo:
Several activities were conducted during my PhD activity. For the NEMO experiment a collaboration between the INFN/University groups of Catania and Bologna led to the development and production of a mixed signal acquisition board for the Nemo Km3 telescope. The research concerned the feasibility study for a different acquisition technique quite far from that adopted in the NEMO Phase 1 telescope. The DAQ board that we realized exploits the LIRA06 front-end chip for the analog acquisition of anodic an dynodic sources of a PMT (Photo-Multiplier Tube). The low-power analog acquisition allows to sample contemporaneously multiple channels of the PMT at different gain factors in order to increase the signal response linearity over a wider dynamic range. Also the auto triggering and self-event-classification features help to improve the acquisition performance and the knowledge on the neutrino event. A fully functional interface towards the first level data concentrator, the Floor Control Module, has been integrated as well on the board, and a specific firmware has been realized to comply with the present communication protocols. This stage of the project foresees the use of an FPGA, a high speed configurable device, to provide the board with a flexible digital logic control core. After the validation of the whole front-end architecture this feature would be probably integrated in a common mixed-signal ASIC (Application Specific Integrated Circuit). The volatile nature of the configuration memory of the FPGA implied the integration of a flash ISP (In System Programming) memory and a smart architecture for a safe remote reconfiguration of it. All the integrated features of the board have been tested. At the Catania laboratory the behavior of the LIRA chip has been investigated in the digital environment of the DAQ board and we succeeded in driving the acquisition with the FPGA. The PMT pulses generated with an arbitrary waveform generator were correctly triggered and acquired by the analog chip, and successively they were digitized by the on board ADC under the supervision of the FPGA. For the communication towards the data concentrator a test bench has been realized in Bologna where, thanks to a lending of the Roma University and INFN, a full readout chain equivalent to that present in the NEMO phase-1 was installed. These tests showed a good behavior of the digital electronic that was able to receive and to execute command imparted by the PC console and to answer back with a reply. The remotely configurable logic behaved well too and demonstrated, at least in principle, the validity of this technique. A new prototype board is now under development at the Catania laboratory as an evolution of the one described above. This board is going to be deployed within the NEMO Phase-2 tower in one of its floors dedicated to new front-end proposals. This board will integrate a new analog acquisition chip called SAS (Smart Auto-triggering Sampler) introducing thus a new analog front-end but inheriting most of the digital logic present in the current DAQ board discussed in this thesis. For what concern the activity on high-resolution vertex detectors, I worked within the SLIM5 collaboration for the characterization of a MAPS (Monolithic Active Pixel Sensor) device called APSEL-4D. The mentioned chip is a matrix of 4096 active pixel sensors with deep N-well implantations meant for charge collection and to shield the analog electronics from digital noise. The chip integrates the full-custom sensors matrix and the sparsifification/readout logic realized with standard-cells in STM CMOS technology 130 nm. For the chip characterization a test-beam has been set up on the 12 GeV PS (Proton Synchrotron) line facility at CERN of Geneva (CH). The collaboration prepared a silicon strip telescope and a DAQ system (hardware and software) for data acquisition and control of the telescope that allowed to store about 90 million events in 7 equivalent days of live-time of the beam. My activities concerned basically the realization of a firmware interface towards and from the MAPS chip in order to integrate it on the general DAQ system. Thereafter I worked on the DAQ software to implement on it a proper Slow Control interface of the APSEL4D. Several APSEL4D chips with different thinning have been tested during the test beam. Those with 100 and 300 um presented an overall efficiency of about 90% imparting a threshold of 450 electrons. The test-beam allowed to estimate also the resolution of the pixel sensor providing good results consistent with the pitch/sqrt(12) formula. The MAPS intrinsic resolution has been extracted from the width of the residual plot taking into account the multiple scattering effect.
Resumo:
The main reasons for the attention focused on ceramics as possible structural materials are their wear resistance and the ability to operate with limited oxidation and ablation at temperatures above 2000°C. Hence, this work is devoted to the study of two classes of materials which can satisfy these requirements: silicon carbide -based ceramics (SiC) for wear applications and borides and carbides of transition metals for ultra-high temperatures applications (UHTCs). SiC-based materials: Silicon carbide is a hard ceramic, which finds applications in many industrial sectors, from heat production, to automotive engineering and metals processing. In view of new fields of uses, SiC-based ceramics were produced with addition of 10-30 vol% of MoSi2, in order to obtain electro conductive ceramics. MoSi2, indeed, is an intermetallic compound which possesses high temperature oxidation resistance, high electrical conductivity (21·10-6 Ω·cm), relatively low density (6.31 g/cm3), high melting point (2030°C) and high stiffness (440 GPa). The SiC-based ceramics were hot pressed at 1900°C with addition of Al2O3-Y2O3 or Y2O3-AlN as sintering additives. The microstructure of the composites and of the reference materials, SiC and MoSi2, were studied by means of conventional analytical techniques, such as X-ray diffraction (XRD), scanning electron microscopy (SEM) and energy dispersive spectroscopy (SEM-EDS). The composites showed a homogeneous microstructure, with good dispersion of the secondary phases and low residual porosity. The following thermo-mechanical properties of the SiC-based materials were measured: Vickers hardness (HV), Young’s modulus (E), fracture toughness (KIc) and room to high temperature flexural strength (σ). The mechanical properties of the composites were compared to those of two monolithic SiC and MoSi2 materials and resulted in a higher stiffness, fracture toughness and slightly higher flexural resistance. Tribological tests were also performed in two configurations disco-on-pin and slideron cylinder, aiming at studying the wear behaviour of SiC-MoSi2 composites with Al2O3 as counterfacing materials. The tests pointed out that the addition of MoSi2 was detrimental owing to a lower hardness in comparison with the pure SiC matrix. On the contrary, electrical measurements revealed that the addition of 30 vol% of MoSi2, rendered the composite electroconductive, lowering the electrical resistance of three orders of magnitude. Ultra High Temperature Ceramics: Carbides, borides and nitrides of transition metals (Ti, Zr, Hf, Ta, Nb, Mo) possess very high melting points and interesting engineering properties, such as high hardness (20-25 GPa), high stiffness (400-500 GPa), flexural strengths which remain unaltered from room temperature to 1500°C and excellent corrosion resistance in aggressive environment. All these properties place the UHTCs as potential candidates for the development of manoeuvrable hypersonic flight vehicles with sharp leading edges. To this scope Zr- and Hf- carbide and boride materials were produced with addition of 5-20 vol% of MoSi2. This secondary phase enabled the achievement of full dense composites at temperature lower than 2000°C and without the application of pressure. Besides the conventional microstructure analyses XRD and SEM-EDS, transmission electron microscopy (TEM) was employed to explore the microstructure on a small length scale to disclose the effective densification mechanisms. A thorough literature analysis revealed that neither detailed TEM work nor reports on densification mechanisms are available for this class of materials, which however are essential to optimize the sintering aids utilized and the processing parameters applied. Microstructural analyses, along with thermodynamics and crystallographic considerations, led to disclose of the effective role of MoSi2 during sintering of Zrand Hf- carbides and borides. Among the investigated mechanical properties (HV, E, KIc, σ from room temperature to 1500°C), the high temperature flexural strength was improved due to the protective and sealing effect of a silica-based glassy phase, especially for the borides. Nanoindentation tests were also performed on HfC-MoSi2 composites in order to extract hardness and elastic modulus of the single phases. Finally, arc jet tests on HfC- and HfB2-based composites confirmed the excellent oxidation behaviour of these materials under temperature exceeding 2000°C; no cracking or spallation occurred and the modified layer was only 80-90 μm thick.
Resumo:
The most relevant thermo-mechanical properties of SiC or C based CFCCs are high strength, high toughness, low weight, high reliability, thermal shock and fatigue resistance. Thanks to these special characteristics, the CFCCs are the best candidates to substitute metals and monolithic ceramics, traditionally employed to realize components in energy, aeronautic and nuclear fields. Among the commonly techniques for the CFCCs production, CVI still represents the most significant one. Its main advantages are the versatility, the high quality deposits and the fact that it is conducted under mild temperature conditions. On the other hand, this technique is quite complex, therefore the set up of all process parameters needs long development time. The main purpose of the present study was to analyze the parameters controlling the CVD and CVI processes. Specifically, deposition and infiltration of SiC and Py-C tests were conducted on non-porous and porous substrates. The experiments were performed with a pilot size Isothermal/Isobaric CVI plant, designed and developed by ENEA. To guarantee the control of the process parameters, a previously optimization of the plant was needed. Changing temperature, pressure, flow rates and methane/hydrogen ratio, the Py-C deposition rate value, for an optimal fibre/matrix interphase thickness, was determined. It was also underlined the hydrogen inhibiting effect over the Py-C deposition rate. Regarding SiC morphologies, a difference between the inner and outer substrate surfaces was observed, as a consequence of a flow rate non-uniformity. In the case of the Cf/C composites development, the key parameter of the CVI process was the gas residence time. In fact, the hydrogen inhibiting effect was evident only with high value of residence time. Furthermore, lower the residence time more homogeneous the Py-C deposition rate was obtained along the reaction chamber axis. Finally, a CVD and CVI theoretical modelling was performed.
Resumo:
Varcare le frontiere della Storia attraverso le storie personali dei suoi personaggi ha sempre affascinato la sensibilità creatrice di Anita Desai, i cui romanzi possono essere considerati un interessante esempio di letteratura di confine, che riesce nel difficile compito di misurarsi, con eleganza e sensibilità, nella rappresentazione delle più feroci forme di marginalizzazione. Proponendo un dialogo tra alterità, che apre alle complessità storico-culturali in maniera del tutto a-ideologica e imparziale, la scrittrice indoinglese procede alla “provincializzazione” dell’India attraverso le numerose ambivalenze prodotte nelle zone frontaliere analizzate. Dalla rappresentazione della frontiera identitaria esterna, ovvero dall’ambivalente rapporto intrattenuto con il colonizzatore/ex-colonizzatore inglese, alla rappresentazione della frontiera identitaria interna, ovvero l’analisi delle contraddittorie relazioni tra le componenti etniche del subcontinente, Desai arriva infine a problematizzare storie di ambivalenti processi di marginalizzazione prodotti da mondi culturali così diversi come la Germania nazista, o gli indiani Huichol del lontano Messico, tracciando geografie culturali inedite della grande ragnatela della Storia. Desai riesce così a recuperare voci liminali spesso trascurate dalla postcolonialità stessa, per riconfigurarle in un’esplorazione profonda del comune destino dell’umanità, voci straniate e stranianti che acquisiscono un vero e proprio status di agency discorsiva, proiettando la sua scrittura verso una dimensione cosmopolitica. L’opera di Desai diventa indubbiamente un’opportunità concreta per scorgere nella differenza l’universalità di una comune umanità, vale a dire un’opportunità per vedere nell’alterità un’identità ribaltata.
Resumo:
The diameters of traditional dish concentrators can reach several tens of meters, the construction of monolithic mirrors being difficult at these scales: cheap flat reflecting facets mounted on a common frame generally reproduce a paraboloidal surface. When a standard imaging mirror is coupled with a PV dense array, problems arise since the solar image focused is intrinsically circular. Moreover, the corresponding irradiance distribution is bell-shaped in contrast with the requirement of having all the cells under the same illumination. Mismatch losses occur when interconnected cells experience different conditions, in particular in series connections. In this PhD Thesis, we aim at solving these issues by a multidisciplinary approach, exploiting optical concepts and applications developed specifically for astronomical use, where the improvement of the image quality is a very important issue. The strategy we propose is to boost the spot uniformity acting uniquely on the primary reflector and avoiding the big mirrors segmentation into numerous smaller elements that need to be accurately mounted and aligned. In the proposed method, the shape of the mirrors is analytically described by the Zernike polynomials and its optimization is numerically obtained to give a non-imaging optics able to produce a quasi-square spot, spatially uniform and with prescribed concentration level. The freeform primary optics leads to a substantial gain in efficiency without secondary optics. Simple electrical schemes for the receiver are also required. The concept has been investigated theoretically modeling an example of CPV dense array application, including the development of non-optical aspects as the design of the detector and of the supporting mechanics. For the method proposed and the specific CPV system described, a patent application has been filed in Italy with the number TO2014A000016. The patent has been developed thanks to the collaboration between the University of Bologna and INAF (National Institute for Astrophysics).
Resumo:
This dissertation deals with the design and the characterization of novel reconfigurable silicon-on-insulator (SOI) devices to filter and route optical signals on-chip. Design is carried out through circuit simulations based on basic circuit elements (Building Blocks, BBs) in order to prove the feasibility of an approach allowing to move the design of Photonic Integrated Circuits (PICs) toward the system level. CMOS compatibility and large integration scale make SOI one of the most promising material to realize PICs. The concepts of generic foundry and BB based circuit simulations for the design are emerging as a solution to reduce the costs and increase the circuit complexity. To validate the BB based approach, the development of some of the most important BBs is performed first. A novel tunable coupler is also presented and it is demonstrated to be a valuable alternative to the known solutions. Two novel multi-element PICs are then analysed: a narrow linewidth single mode resonator and a passband filter with widely tunable bandwidth. Extensive circuit simulations are carried out to determine their performance, taking into account fabrication tolerances. The first PIC is based on two Grating Assisted Couplers in a ring resonator (RR) configuration. It is shown that a trade-off between performance, resonance bandwidth and device footprint has to be performed. The device could be employed to realize reconfigurable add-drop de/multiplexers. Sensitivity with respect to fabrication tolerances and spurious effects is however observed. The second PIC is based on an unbalanced Mach-Zehnder interferometer loaded with two RRs. Overall good performance and robustness to fabrication tolerances and nonlinear effects have confirmed its applicability for the realization of flexible optical systems. Simulated and measured devices behaviour is shown to be in agreement thus demonstrating the viability of a BB based approach to the design of complex PICs.