9 resultados para Methods, Validation
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
Background. The surgical treatment of dysfunctional hips is a severe condition for the patient and a costly therapy for the public health. Hip resurfacing techniques seem to hold the promise of various advantages over traditional THR, with particular attention to young and active patients. Although the lesson provided in the past by many branches of engineering is that success in designing competitive products can be achieved only by predicting the possible scenario of failure, to date the understanding of the implant quality is poorly pre-clinically addressed. Thus revision is the only delayed and reliable end point for assessment. The aim of the present work was to model the musculoskeletal system so as to develop a protocol for predicting failure of hip resurfacing prosthesis. Methods. Preliminary studies validated the technique for the generation of subject specific finite element (FE) models of long bones from Computed Thomography data. The proposed protocol consisted in the numerical analysis of the prosthesis biomechanics by deterministic and statistic studies so as to assess the risk of biomechanical failure on the different operative conditions the implant might face in a population of interest during various activities of daily living. Physiological conditions were defined including the variability of the anatomy, bone densitometry, surgery uncertainties and published boundary conditions at the hip. The protocol was tested by analysing a successful design on the market and a new prototype of a resurfacing prosthesis. Results. The intrinsic accuracy of models on bone stress predictions (RMSE < 10%) was aligned to the current state of the art in this field. The accuracy of prediction on the bone-prosthesis contact mechanics was also excellent (< 0.001 mm). The sensitivity of models prediction to uncertainties on modelling parameter was found below 8.4%. The analysis of the successful design resulted in a very good agreement with published retrospective studies. The geometry optimisation of the new prototype lead to a final design with a low risk of failure. The statistical analysis confirmed the minimal risk of the optimised design over the entire population of interest. The performances of the optimised design showed a significant improvement with respect to the first prototype (+35%). Limitations. On the authors opinion the major limitation of this study is on boundary conditions. The muscular forces and the hip joint reaction were derived from the few data available in the literature, which can be considered significant but hardly representative of the entire variability of boundary conditions the implant might face over the patients population. This moved the focus of the research on modelling the musculoskeletal system; the ongoing activity is to develop subject-specific musculoskeletal models of the lower limb from medical images. Conclusions. The developed protocol was able to accurately predict known clinical outcomes when applied to a well-established device and, to support the design optimisation phase providing important information on critical characteristics of the patients when applied to a new prosthesis. The presented approach does have a relevant generality that would allow the extension of the protocol to a large set of orthopaedic scenarios with minor changes. Hence, a failure mode analysis criterion can be considered a suitable tool in developing new orthopaedic devices.
Resumo:
The human movement analysis (HMA) aims to measure the abilities of a subject to stand or to walk. In the field of HMA, tests are daily performed in research laboratories, hospitals and clinics, aiming to diagnose a disease, distinguish between disease entities, monitor the progress of a treatment and predict the outcome of an intervention [Brand and Crowninshield, 1981; Brand, 1987; Baker, 2006]. To achieve these purposes, clinicians and researchers use measurement devices, like force platforms, stereophotogrammetric systems, accelerometers, baropodometric insoles, etc. This thesis focus on the force platform (FP) and in particular on the quality assessment of the FP data. The principal objective of our work was the design and the experimental validation of a portable system for the in situ calibration of FPs. The thesis is structured as follows: Chapter 1. Description of the physical principles used for the functioning of a FP: how these principles are used to create force transducers, such as strain gauges and piezoelectrics transducers. Then, description of the two category of FPs, three- and six-component, the signals acquisition (hardware structure), and the signals calibration. Finally, a brief description of the use of FPs in HMA, for balance or gait analysis. Chapter 2. Description of the inverse dynamics, the most common method used in the field of HMA. This method uses the signals measured by a FP to estimate kinetic quantities, such as joint forces and moments. The measures of these variables can not be taken directly, unless very invasive techniques; consequently these variables can only be estimated using indirect techniques, as the inverse dynamics. Finally, a brief description of the sources of error, present in the gait analysis. Chapter 3. State of the art in the FP calibration. The selected literature is divided in sections, each section describes: systems for the periodic control of the FP accuracy; systems for the error reduction in the FP signals; systems and procedures for the construction of a FP. In particular is detailed described a calibration system designed by our group, based on the theoretical method proposed by ?. This system was the “starting point” for the new system presented in this thesis. Chapter 4. Description of the new system, divided in its parts: 1) the algorithm; 2) the device; and 3) the calibration procedure, for the correct performing of the calibration process. The algorithm characteristics were optimized by a simulation approach, the results are here presented. In addiction, the different versions of the device are described. Chapter 5. Experimental validation of the new system, achieved by testing it on 4 commercial FPs. The effectiveness of the calibration was verified by measuring, before and after calibration, the accuracy of the FPs in measuring the center of pressure of an applied force. The new system can estimate local and global calibration matrices; by local and global calibration matrices, the non–linearity of the FPs was quantified and locally compensated. Further, a non–linear calibration is proposed. This calibration compensates the non– linear effect in the FP functioning, due to the bending of its upper plate. The experimental results are presented. Chapter 6. Influence of the FP calibration on the estimation of kinetic quantities, with the inverse dynamics approach. Chapter 7. The conclusions of this thesis are presented: need of a calibration of FPs and consequential enhancement in the kinetic data quality. Appendix: Calibration of the LC used in the presented system. Different calibration set–up of a 3D force transducer are presented, and is proposed the optimal set–up, with particular attention to the compensation of non–linearities. The optimal set–up is verified by experimental results.
Resumo:
Magnetic resonance imaging (MRI) is today precluded to patients bearing active implantable medical devices AIMDs). The great advantages related to this diagnostic modality, together with the increasing number of people benefiting from implantable devices, in particular pacemakers(PM)and carioverter/defibrillators (ICD), is prompting the scientific community the study the possibility to extend MRI also to implanted patients. The MRI induced specific absorption rate (SAR) and the consequent heating of biological tissues is one of the major concerns that makes patients bearing metallic structures contraindicated for MRI scans. To date, both in-vivo and in-vitro studies have demonstrated the potentially dangerous temperature increase caused by the radiofrequency (RF) field generated during MRI procedures in the tissues surrounding thin metallic implants. On the other side, the technical evolution of MRI scanners and of AIMDs together with published data on the lack of adverse events have reopened the interest in this field and suggest that, under given conditions, MRI can be safely performed also in implanted patients. With a better understanding of the hazards of performing MRI scans on implanted patients as well as the development of MRI safe devices, we may soon enter an era where the ability of this imaging modality may be more widely used to assist in the appropriate diagnosis of patients with devices. In this study both experimental measures and numerical analysis were performed. Aim of the study is to systematically investigate the effects of the MRI RF filed on implantable devices and to identify the elements that play a major role in the induced heating. Furthermore, we aimed at developing a realistic numerical model able to simulate the interactions between an RF coil for MRI and biological tissues implanted with a PM, and to predict the induced SAR as a function of the particular path of the PM lead. The methods developed and validated during the PhD program led to the design of an experimental framework for the accurate measure of PM lead heating induced by MRI systems. In addition, numerical models based on Finite-Differences Time-Domain (FDTD) simulations were validated to obtain a general tool for investigating the large number of parameters and factors involved in this complex phenomenon. The results obtained demonstrated that the MRI induced heating on metallic implants is a real risk that represents a contraindication in extending MRI scans also to patient bearing a PM, an ICD, or other thin metallic objects. On the other side, both experimental data and numerical results show that, under particular conditions, MRI procedures might be consider reasonably safe also for an implanted patient. The complexity and the large number of variables involved, make difficult to define a unique set of such conditions: when the benefits of a MRI investigation cannot be obtained using other imaging techniques, the possibility to perform the scan should not be immediately excluded, but some considerations are always needed.
Resumo:
Researches performed during the PhD course intended to assess innovative applications of near-infrared spectroscopy in reflectance (NIR) in the production chain of beer. The purpose is to measure by NIR the "malting quality" (MQ) parameter of barley, to monitor the malting process and to know if a certain type of barley is suitable for the production of beer and spirits. Moreover, NIR will be applied to monitor the brewing process. First of all, it was possible to check the quality of the raw materials like barley, maize and barley malt using a rapid, non-destructive and reliable method, with a low error of prediction. The more interesting result obtained at this level was that the repeatability of the NIR calibration models developed was comparable with the one of the reference method. Moreover, about malt, new kinds of validation were used in order to estimate the real predictive power of the proposed calibration models and to understand the long-term effects. Furthermore, the precision of all the calibration models developed for malt evaluation was estimated and statistically compared with the reference methods, with good results. Then, new calibration models were developed for monitoring the malting process, measuring the moisture content and other malt quality parameters during germination. Moreover it was possible to obtain by NIR an estimate of the "malting quality" (MQ) of barley and to predict whether if its germination will be rapid and uniform and if a certain type of barley is suitable for the production of beer and spirits. Finally, the NIR technique was applied to monitor the brewing process, using correlations between NIR spectra of beer and analytical parameters, and to assess beer quality. These innovative results are potentially very useful for the actors involved in the beer production chain, especially the calibration models suitable for the control of the malting process and for the assessment of the “malting quality” of barley, which need to be deepened in future studies.
Resumo:
The research activity characterizing the present thesis was mainly centered on the design, development and validation of methodologies for the estimation of stationary and time-varying connectivity between different regions of the human brain during specific complex cognitive tasks. Such activity involved two main aspects: i) the development of a stable, consistent and reproducible procedure for functional connectivity estimation with a high impact on neuroscience field and ii) its application to real data from healthy volunteers eliciting specific cognitive processes (attention and memory). In particular the methodological issues addressed in the present thesis consisted in finding out an approach to be applied in neuroscience field able to: i) include all the cerebral sources in connectivity estimation process; ii) to accurately describe the temporal evolution of connectivity networks; iii) to assess the significance of connectivity patterns; iv) to consistently describe relevant properties of brain networks. The advancement provided in this thesis allowed finding out quantifiable descriptors of cognitive processes during a high resolution EEG experiment involving subjects performing complex cognitive tasks.
Resumo:
In this thesis the evolution of the techno-social systems analysis methods will be reported, through the explanation of the various research experience directly faced. The first case presented is a research based on data mining of a dataset of words association named Human Brain Cloud: validation will be faced and, also through a non-trivial modeling, a better understanding of language properties will be presented. Then, a real complex system experiment will be introduced: the WideNoise experiment in the context of the EveryAware european project. The project and the experiment course will be illustrated and data analysis will be displayed. Then the Experimental Tribe platform for social computation will be introduced . It has been conceived to help researchers in the implementation of web experiments, and aims also to catalyze the cumulative growth of experimental methodologies and the standardization of tools cited above. In the last part, three other research experience which already took place on the Experimental Tribe platform will be discussed in detail, from the design of the experiment to the analysis of the results and, eventually, to the modeling of the systems involved. The experiments are: CityRace, about the measurement of human traffic-facing strategies; laPENSOcosì, aiming to unveil the political opinion structure; AirProbe, implemented again in the EveryAware project framework, which consisted in monitoring air quality opinion shift of a community informed about local air pollution. At the end, the evolution of the technosocial systems investigation methods shall emerge together with the opportunities and the threats offered by this new scientific path.
Resumo:
Heavy Liquid Metal Cooled Reactors are among the concepts, fostered by the GIF, as potentially able to comply with stringent safety, economical, sustainability, proliferation resistance and physical protection requirements. The increasing interest around these innovative systems has highlighted the lack of tools specifically dedicated to their core design stage. The present PhD thesis summarizes the three years effort of, partially, closing the mentioned gap, by rationally defining the role of codes in core design and by creating a development methodology for core design-oriented codes (DOCs) and its subsequent application to the most needed design areas. The covered fields are, in particular, the fuel assembly thermal-hydraulics and the fuel pin thermo-mechanics. Regarding the former, following the established methodology, the sub-channel code ANTEO+ has been conceived. Initially restricted to the forced convection regime and subsequently extended to the mixed one, ANTEO+, via a thorough validation campaign, has been demonstrated a reliable tool for design applications. Concerning the fuel pin thermo-mechanics, the will to include safety-related considerations at the outset of the pin dimensioning process, has given birth to the safety-informed DOC TEMIDE. The proposed DOC development methodology has also been applied to TEMIDE; given the complex interdependence patterns among the numerous phenomena involved in an irradiated fuel pin, to optimize the code final structure, a sensitivity analysis has been performed, in the anticipated application domain. The development methodology has also been tested in the verification and validation phases; the latter, due to the low availability of experiments truly representative of TEMIDE's application domain, has only been a preliminary attempt to test TEMIDE's capabilities in fulfilling the DOC requirements upon which it has been built. In general, the capability of the proposed development methodology for DOCs in delivering tools helping the core designer in preliminary setting the system configuration has been proven.
Resumo:
The porpoise of this study was to implement research methodologies and assess the effectiveness and impact of management tools to promote best practices for the long term conservation of the endangered African wild dog (Lycaon pictus). Different methods were included in the project framework to investigate and expand the applicability of these methodologies to free-ranging African wild dogs in the southern African region: ethology, behavioural endocrinology and ecology field methodologies were tested and implemented. Additionally, research was performed to test the effectiveness and implication of a contraceptive implant (Suprenolin) as a management tool for the species of a subpopulation hosted in fenced areas. Attention was especially given to social structure and survival of treated packs. This research provides useful tools and advances the applicability of these methods for field studies, standardizing and improving research instruments in the field of conservation biology and behavioural endocrinology. Results reported here provide effective methodologies to expand the applicability of non-invasive endocrine assessment to previously prohibited fields, and validation of sampling methods for faecal hormone analysis. The final aim was to fill a knowledge gap on behaviours of the species and provide a common ground for future researchers to apply non-invasive methods to this species research and to test the effectiveness of the contraception on a managed metapopulation.
Resumo:
Background Echocardiography is the cornerstone in the evaluation of cardiac masses and provides accurate characterization. Despite, its accuracy in diagnosis of cardiac masses (CM) remains challenging and, up to date, no validated diagnostic algorithm is validated. Purpose The aim of our study was to evaluate the diagnostic accuracy of echocardiography, to identify the echocardiographic predictors of malignancy and to develop and then validate a multiparametric echocardiographic score that could be used to estimate the likelihood of the histological nature of a CM. Materials and methods The final sample consisted of 273 consecutive patients who had a 2D-echocardiographic evaluation and a histologic diagnosis. Logistic regression was performed to evaluate the ability of echocardiographic findings to discriminate benign versus malignant masses, then a scoring system was developed and validated in a separate test cohort. Results Of the 322 patients initially included in the Bologna Cardiac Masses Registry, 13 with a poor acoustic window, 27 with no histological examination patients and 9 extra-cardiac masses were excluded. In the remaining 273 patients, classical 2-D echocardiogram identified 249 masses with a diagnostic accuracy of 88%. A weighted score [Diagnostic Echocardiographic Mass (DEM) Score] ranging from 0 to 9 was obtained from 6 variables: infiltration, polylobate mass, moderate-severe pericardial effusion. The AUC for the score was 0.965 (95% CI [0.938-0.993]). In a logistic regression analysis using the DEM score as a predictor, the likelihood of malignant CM increased more than 4 times for a 1-unit increase in the score (OR=4.468; 95% CI 2.733-7.304). A score < 3 denoted a high probability of a benign diagnosis, and a score ≥ 5 points corresponded to a higher risk of malignancy. Conclusion 2D-Echocardiography provides a high diagnostic accuracy in identifying cardiac masses and our multiparametric echocardiographic score could be useful to predict the histological nature of cardiac masses.