5 resultados para Merge and acquisitions
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.
Resumo:
Can space and place foster child development, and in particular social competence and ecological literacy? If yes, how can space and place do that? This study shows that the answer to the first question is positive and then tries to explain the way space and place can make a difference. The thesis begins with the review of literature from different disciplines – child development and child psychology, education, environmental psychology, architecture and landscape architecture. Some bridges among such disciplines are created and in some cases the ideas from the different areas of research merge: thus, this is an interdisciplinary study. The interdisciplinary knowledge from these disciplines is translated into a range of design suggestions that can foster the development of social competence and ecological literacy. Using scientific knowledge from different disciplines is a way of introducing forms of evidence into the development of design criteria. However, the definition of design criteria also has to pass through the study of a series of school buildings and un-built projects: case studies can give a positive contribution to the criteria because examples and good practices can help “translating” the theoretical knowledge into design ideas and illustrations. To do that, the different case studies have to be assessed in relation to the various themes that emerged in the literature review. Finally, research by design can be used to help define the illustrated design criteria: based on all the background knowledge that has been built, the role of the architect is to provide a series of different design solutions that can give answers to the different “questions” emerged in the literature review.
Resumo:
The work of the present thesis is focused on the implementation of microelectronic voltage sensing devices, with the purpose of transmitting and extracting analog information between devices of different nature at short distances or upon contact. Initally, chip-to-chip communication has been studied, and circuitry for 3D capacitive coupling has been implemented. Such circuits allow the communication between dies fabricated in different technologies. Due to their novelty, they are not standardized and currently not supported by standard CAD tools. In order to overcome such burden, a novel approach for the characterization of such communicating links has been proposed. This results in shorter design times and increased accuracy. Communication between an integrated circuit (IC) and a probe card has been extensively studied as well. Today wafer probing is a costly test procedure with many drawbacks, which could be overcome by a different communication approach such as capacitive coupling. For this reason wireless wafer probing has been investigated as an alternative approach to standard on-contact wafer probing. Interfaces between integrated circuits and biological systems have also been investigated. Active electrodes for simultaneous electroencephalography (EEG) and electrical impedance tomography (EIT) have been implemented for the first time in a 0.35 um process. Number of wires has been minimized by sharing the analog outputs and supply on a single wire, thus implementing electrodes that require only 4 wires for their operation. Minimization of wires reduces the cable weight and thus limits the patient's discomfort. The physical channel for communication between an IC and a biological medium is represented by the electrode itself. As this is a very crucial point for biopotential acquisitions, large efforts have been carried in order to investigate the different electrode technologies and geometries and an electromagnetic model is presented in order to characterize the properties of the electrode to skin interface.
Resumo:
The objective of this study is to provide empirical evidence on how ownership structure and owner’s identity affect performance, in the banking industry by using a panel of Indonesia banks over the period 2000–2009. Firstly, we analysed the impact of the presence of multiple blockholders on bank ownership structure and performance. Building on multiple agency and principal-principal theories, we investigated whether the presence and shares dispersion across blockholders with different identities (i.e. central and regional government; families; foreign banks and financial institutions) affected bank performance, in terms of profitability and efficiency. We found that the number of blockholders has a negative effect on banks’ performance, while blockholders’ concentration has a positive effect. Moreover, we observed that the dispersion of ownership across different types of blockholders has a negative effect on banks’ performance. We interpret such results as evidence that, when heterogeneous blockholders are present, the disadvantage from conflicts of interests between blockholders seems to outweigh the advantage of the increase in additional monitoring by additional blockholder. Secondly, we conducted a joint analysis of the static, selection, and dynamic effects of different types of ownership on banks’ performance. We found that regional banks and foreign banks have a higher profitability and efficiency as compared to domestic private banks. In the short-run, foreign acquisitions and domestic M&As reduce the level of overhead costs, while in the long-run they increase the Net Interest Margin (NIM). Further, we analysed NIM determinants, to asses the impact of ownership on bank business orientation. Our findings lend support to our prediction that the NIM determinants differs accordingly to the type of bank ownership. We also observed that banks that experienced changes in ownership, such as foreign-acquired banks, manifest different interest margin determinants with respect to domestic or foreign banks that did not experience ownership rearrangements.
Resumo:
It is usual to hear a strange short sentence: «Random is better than...». Why is randomness a good solution to a certain engineering problem? There are many possible answers, and all of them are related to the considered topic. In this thesis I will discuss about two crucial topics that take advantage by randomizing some waveforms involved in signals manipulations. In particular, advantages are guaranteed by shaping the second order statistic of antipodal sequences involved in an intermediate signal processing stages. The first topic is in the area of analog-to-digital conversion, and it is named Compressive Sensing (CS). CS is a novel paradigm in signal processing that tries to merge signal acquisition and compression at the same time. Consequently it allows to direct acquire a signal in a compressed form. In this thesis, after an ample description of the CS methodology and its related architectures, I will present a new approach that tries to achieve high compression by design the second order statistics of a set of additional waveforms involved in the signal acquisition/compression stage. The second topic addressed in this thesis is in the area of communication system, in particular I focused the attention on ultra-wideband (UWB) systems. An option to produce and decode UWB signals is direct-sequence spreading with multiple access based on code division (DS-CDMA). Focusing on this methodology, I will address the coexistence of a DS-CDMA system with a narrowband interferer. To do so, I minimize the joint effect of both multiple access (MAI) and narrowband (NBI) interference on a simple matched filter receiver. I will show that, when spreading sequence statistical properties are suitably designed, performance improvements are possible with respect to a system exploiting chaos-based sequences minimizing MAI only.