7 resultados para Measurement--Study and teaching--Early works to 1800

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The early identification of responsive and resistant patients to androgen-receptor targeting agents (ARTA) in metastatic castration resistant-prostate cancer (CRPC) is not completely possible with PSA assessment and conventional imaging. Considering its ability to determine metabolic activity of lesions, PET assessment might be a promising tool. Materials and methods: We performed a monocentric prospective study in patients with metastatic CRPC under treatment with ARTA to evaluate the role of different PET radiotracers: 49 patients were randomized to receive 11C-Choline, 18F-FACBC or 68Ga-PSMA PET, one scan before therapy onset and one two months later. The primary aim was to investigate the performance of three different novel PET radiotracers for the early evaluation of response to ARTA in metastatic CRPC patients; with regards to this aim, the outcome evaluated was biochemical response (PSA reduction ≥50%). The secondary aim was to investigate the prognostic role of several semiquantitative PET parameters and their variations with the different radiotracers in terms of biochemical PFS (bPFS) and overall survival (OS). The study was promoted by the Italian Department of Health (code RF-2016-02364809). Results: With regards to the primary endpoint, at univariate analysis a statistically significant correlation was found between MTV_VARIATION% (p=0.018) and TLA_VARIATION% (p=0.025) with 68Ga-PSMA PET and biochemical response. As for the secondary endpoints, significant correlations with bPFS were found for 68Ga-PSMA PET MTV_TOT_PET1 (p=0.001), TLA_TOT_PET1 (p=0.025), MTV_VARIATION% (p=0.031). For OS, statistically significant correlations were found for: MAJ_SUV_MAX_PET1 with 11C-Choline PET (p=0.007); MTV_TOT_PET1 (p=0.004), MAJ_SUV_MAX_PET1 (p=0.029), SUVMAX_VARIATION% (p=0.04), MTV_VARIATION% (p=0.015), TLA_VARIATION% (p=0.03) with 68Ga-PSMA PET,; MTV_TOT_PET1 (p=0.011), TLA_TOT_PET1 (p=0.009), MAJ_SUV_MAX_PET1 (p=0.027), MTV_VARIATION% (p=0.048) with 18F-FACBC. Conclusions: Our prospective study highlighted that several 68Ga-PSMA and 18F-FACBC semiquantitative PET parameters and their variations present a prognostic value in terms of OS and bPFS and a correlation with biochemical response, that could help to assess response to ARTA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bone remodelling is a fundamental mechanism for removing and replacing bone during adaptation of the skeleton to mechanical loads. Skeletal unloading leads to severe hypoxia (1%O2) in the bone microenvironment resulting in imbalanced bone remodelling that favours bone resorption. Hypoxia, in vivo, is a physiological condition for osteocytes, 5% O2 is more likely physiological for osteocytes than 20% O2, as osteocytes are embedded deep inside the mineralized bone matrix. Osteocytes are thought to be the mechanosensors of bone and have been shown to orchestrate bone formation and resorption. Oxygen-deprived osteocytes seem undergo apoptosis and actively stimulate osteoclasts. Hypoxia and oxidative stress increase 150-kDa oxygen-regulated protein (ORP 150) expression in different cell types. It is a novel endoplasmic-reticulum-associated chaperone induced by hypoxia/ischemia. It well known that ORP 150 plays an important role in the cellular adaptation to hypoxia, as anti-apoptotic factor, and seems to be involved in osteocytes differentiations. The aims of the present study are 1) to determine the cellular and molecular response of the osteocytes at two different conditions of oxygen deprivation, 1% and 5% of O2 compared to the atmospheric oxygen concentration at several time points. 2) To clarify the role of hypoxic osteocytes in bone homeostasis through the detection of releasing of soluble factors (RANKL, OPG, PGE2 and Sclerostin). 3) To detect the activation of osteoclast and osteoblast induced by condition media collected from hypoxic and normoxic osteocytes. The data obtained in this study shows that hypoxia compromises the viability of osteocytes and induces apoptosis. Unlike in other cells types, ORP 150 in MLO-Y4 does not seem to be regulated early during hypoxia. The release of soluble factors and the evaluation of osteoclast and osteoblast activation shows that osteocytes, grown under severe oxygen deprivation, play a role in the regulation of both bone resorption and bone formation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dystrophin is a subsarcolemmal protein critical for the integrity of muscle fibers by linking the actin cytoskeleton to the extracellular matrix via the dystroglycan complex. It is reported that dystroglycans are also localized in the skin, at dermal-epidermal junction. Here we show that epidermal melanocytes express dystrophin at the interface with the basement membrane. The full-length muscle isoform mDp427 was clearly detectable in epidermis and in melanocyte cultures as assessed by RNA and western blot analysis. Dystrophin was absent in Duchenne Muscular Dystrophy (DMD) patients melanocytes, and the ultrastructural analysis revealed mitochondrial alterations, similar to those occurring in myoblasts from the same patients. Interestingly, mitochondrial dysfunction of DMD melanocytes reflected the alterations identified in dystrophin-deficient muscle cells. In fact, mitochondria of melanocytes from DMD patients accumulated tetramethylrhodamine methyl ester but, on the contrary of control donor, mitochondria of DMD patients readily depolarized upon the addition of oligomycin, suggesting either that they are maintaining the membrane potential at the expense of glycolytic ATP, or that they are affected by a latent dysfunction unmasked by inhibition of the ATP synthase. Melanocyte cultures can be easily obtained by conventional skin biopsies, less invasive procedure than muscular biopsy, so that they may represent an alternative cellular model to myoblast for studying and monitoring dystrophinopathies also in response to pharmacological treatments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the last decade peach and nectarine fruit have lost considerable market share, due to increased consumer dissatisfaction with quality at retail markets. This is mainly due to harvesting of too immature fruit and high ripening heterogeneity. The main problem is that the traditional used maturity indexes are not able to objectively detect fruit maturity stage, neither the variability present in the field, leading to a difficult post-harvest management of the product and to high fruit losses. To assess more precisely the fruit ripening other techniques and devices can be used. Recently, a new non-destructive maturity index, based on the vis-NIR technology, the Index of Absorbance Difference (IAD), that correlates with fruit degreening and ethylene production, was introduced and the IAD was used to study peach and nectarine fruit ripening from the “field to the fork”. In order to choose the best techniques to improve fruit quality, a detailed description of the tree structure, of fruit distribution and ripening evolution on the tree was faced. More in details, an architectural model (PlantToon®) was used to design the tree structure and the IAD was applied to characterize the maturity stage of each fruit. Their combined use provided an objective and precise evaluation of the fruit ripening variability, related to different training systems, crop load, fruit exposure and internal temperature. Based on simple field assessment of fruit maturity (as IAD) and growth, a model for an early prediction of harvest date and yield, was developed and validated. The relationship between the non-destructive maturity IAD, and the fruit shelf-life, was also confirmed. Finally the obtained results were validated by consumer test: the fruit sorted in different maturity classes obtained a different consumer acceptance. The improved knowledge, leaded to an innovative management of peach and nectarine fruit, from “field to market”.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was aimed to correlate the results of relative germination from in vitro tests by trifloxystrobin with those of qPCR on a wide range of V. inaequalis populations and monoconidial isolates. Samples were collected in Italian and Turkish distinct locations from orchards with different scab management. In this study, an allele-specific qPCR with primer sets designed was successfully developed to quantitatively determine the frequency of QoI-resistant allele G143A in populations and monoconidial isolates of V. inaequalis. qPCR followed a similar pattern to that obtained using in vitro conidial germination test in very sensitive and very resistant populations. However, the variability between two test results was observed in hetereogenous populations. Therefore, the results of correlations between in vitro and qPCR showed a positive but not very high correlation for Venturia inaequalis populations (R2=0.70). On the contrary, this correlation between two assessment methods was very high for monoconidial isolates (R2=0.92). Results obtained in quantitative PCR and from traditional spore germination assay differed for the same fungal population and in some cases, it is difficult to assess the resistance in the field by only qPCR. It was concluded that it is not always possible to correlate the frequency of detection of the mutation with biological assessment. In such situations, monitoring by molecular techniques must be supported by standard in vitro resistance assessments and observation of field performance in order to have correct conclusions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since the publication of the book of Russell and Burch in 1959, scientific research has never stopped improving itself with regard to the important issue of animal experimentation. The European Directive 2010/63/EU “On the protection of animals used for scientific purposes” focuses mainly on the animal welfare, fixing the Russell and Burch’s 3Rs principles as the foundations of the document. In particular, the legislator clearly states the responsibility of the scientific community to improve the number of alternative methods to animal experimentation. The swine is considered a species of relevant interest for translational research and medicine due to its biological similarities with humans. The surgical community has, in fact, recognized the swine as an excellent model replicating the human cardiovascular system. There have been several wild-type and transgenic porcine models which were produced for biomedicine and translational research. Among these, the cardiovascular ones are the most represented. The continuous involvement of the porcine animal model in the biomedical research, as the continuous advances achieved using swine in translational medicine, support the need for alternative methods to animal experimentation involving pigs. The main purpose of the present work was to develop and characterize novel porcine alternative methods for cardiovascular translational biology/medicine. The work was mainly based on two different models: the first consisted in an ex vivo culture of porcine aortic cylinders and the second consisted in an in vitro culture of porcine aortic derived progenitor cells. Both the models were properly characterized and results indicated that they could be useful to the study of vascular biology. Nevertheless, both the models aim to reduce the use of experimental animals and to refine animal based-trials. In conclusion, the present research aims to be a small, but significant, contribution to the important and necessary field of study of alternative methods to animal experimentation.