9 resultados para Long-axis Function
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
The aim of this PhD thesis was to study at a microscopic level different liquid crystal (LC) systems, in order to determine their physical properties, resorting to two distinct methodologies, one involving computer simulations, and the other spectroscopic techniques, in particular electron spin resonance (ESR) spectroscopy. By means of the computer simulation approach we tried to demonstrate this tool effectiveness for calculating anisotropic static properties of a LC material, as well as for predicting its behaviour and features. This required the development and adoption of suitable molecular models based on a convenient intermolecular potentials reflecting the essential molecular features of the investigated system. In particular, concerning the simulation approach, we have set up models for discotic liquid crystal dimers and we have studied, by means of Monte Carlo simulations, their phase behaviour and self-assembling properties, with respect to the simple monomer case. Each discotic dimer is described by two oblate GayBerne ellipsoids connected by a flexible spacer, modelled by a harmonic "spring" of three different lengths. In particular we investigated the effects of dimerization on the transition temperatures, as well as on the characteristics of molecular aggregation displayed and the relative orientational order. Moving to the experimental results, among the many experimental techniques that are typically employed to evaluate LC system distinctive features, ESR has proved to be a powerful tool in microscopic scale investigation of the properties, structure, order and dynamics of these materials. We have taken advantage of the high sensitivity of the ESR spin probe technique to investigate increasingly complex LC systems ranging from devices constituted by a polymer matrix in which LC molecules are confined in shape of nano- droplets, as well as biaxial liquid crystalline elastomers, and dimers whose monomeric units or lateral groups are constituted by rod-like mesogens (11BCB). Reflection-mode holographic-polymer dispersed liquid crystals (H-PDLCs) are devices in which LCs are confined into nanosized (50-300 nm) droplets, arranged in layers which alternate with polymer layers, forming a diffraction grating. We have determined the configuration of the LC local director and we have derived a model of the nanodroplet organization inside the layers. Resorting also to additional information on the nanodroplet size and shape distribution provided by SEM images of the H-PDLC cross-section, the observed director configuration has been modeled as a bidimensional distribution of elongated nanodroplets whose long axis is, on the average, parallel to the layers and whose internal director configuration is a uniaxial quasi- monodomain aligned along the nanodroplet long axis. The results suggest that the molecular organization is dictated mainly by the confinement, explaining, at least in part, the need for switching voltages significantly higher and the observed faster turn-off times in H-PDLCs compared to standard PDLC devices. Liquid crystal elastomers consist in cross-linked polymers, in which mesogens represent the monomers constituting the main chain or the laterally attached side groups. They bring together three important aspects: orientational order in amorphous soft materials, responsive molecular shape and quenched topological constraints. In biaxial nematic liquid crystalline elastomers (BLCEs), two orthogonal directions, rather than the one of normal uniaxial nematic, can be controlled, greatly enhancing their potential value for applications as novel actuators. Two versions of a side-chain BLCEs were characterized: side-on and end-on. Many tests have been carried out on both types of LCE, the main features detected being the lack of a significant dynamical behaviour, together with a strong permanent alignment along the principal director, and the confirmation of the transition temperatures already determined by DSC measurements. The end-on sample demonstrates a less hindered rotation of the side group mesogenic units and a greater freedom of alignment to the magnetic field, as already shown by previous NMR studies. Biaxial nematic ESR static spectra were also obtained on the basis of Molecular Dynamics generated biaxial configurations, to be compared to the experimentally determined ones, as a mean to establish a possible relation between biaxiality and the spectral features. This provides a concrete example of the advantages of combining the computer simulation and spectroscopic approaches. Finally, the dimer α,ω-bis(4'-cyanobiphenyl-4-yl)undecane (11BCB), synthesized in the "quest" for the biaxial nematic phase has been analysed. Its importance lies in the dimer significance as building blocks in the development of new materials to be employed in innovative technological applications, such as faster switching displays, resorting to the easier aligning ability of the secondary director in biaxial phases. A preliminary series of tests were performed revealing the population of mesogenic molecules as divided into two groups: one of elongated straightened conformers sharing a common director, and one of bent molecules, which display no order, being equally distributed in the three dimensions. Employing this model, the calculated values show a consistent trend, confirming at the same time the transition temperatures indicated by the DSC measurements, together with rotational diffusion tensor values that follow closely those of the constituting monomer 5CB.
Resumo:
Introduction The “eversion” technique for carotid endarterectomy (e-CEA), that involves the transection of the internal carotid artery at the carotid bulb and its eversion over the atherosclerotic plaque, has been associated with an increased risk of postoperative hypertension possibly due to a direct iatrogenic damage to the carotid sinus fibers. The aim of this study is to assess the long-term effect of the e-CEA on arterial baroreflex and peripheral chemoreflex function in humans. Methods A retrospective review was conducted on a prospectively compiled computerized database of 3128 CEAs performed on 2617 patients at our Center between January 2001 and March 2006. During this period, a total of 292 patients who had bilateral carotid stenosis ≥70% at the time of the first admission underwent staged bilateral CEAs. Of these, 93 patients had staged bilateral e-CEAs, 126 staged bilateral s- CEAs and 73 had different procedures on each carotid. CEAs were performed with either the eversion or the standard technique with routine Dacron patching in all cases. The study inclusion criteria were bilateral CEA with the same technique on both sides and an uneventful postoperative course after both procedures. We decided to enroll patients submitted to bilateral e-CEA to eliminate the background noise from contralateral carotid sinus fibers. Exclusion criteria were: age >70 years, diabetes mellitus, chronic pulmonary disease, symptomatic ischemic cardiac disease or medical therapy with b-blockers, cardiac arrhythmia, permanent neurologic deficits or an abnormal preoperative cerebral CT scan, carotid restenosis and previous neck or chest surgery or irradiation. Young and aged-matched healthy subjects were also recruited as controls. Patients were assessed by the 4 standard cardiovascular reflex tests, including Lying-to-standing, Orthostatic hypotension, Deep breathing, and Valsalva Maneuver. Indirect autonomic parameters were assessed with a non-invasive approach based on spectral analysis of EKG RR interval, systolic arterial pressure, and respiration variability, performed with an ad hoc software. From the analysis of these parameters the software provides the estimates of spontaneous baroreflex sensitivity (BRS). The ventilatory response to hypoxia was assessed in patients and controls by means of classic rebreathing tests. Results A total of 29 patients (16 males, age 62.4±8.0 years) were enrolled. Overall, 13 patients had undergone bilateral e-CEA (44.8%) and 16 bilateral s-CEA (55.2%) with a mean interval between the procedures of 62±56 days. No patient showed signs or symptoms of autonomic dysfunction, including labile hypertension, tachycardia, palpitations, headache, inappropriate diaphoresis, pallor or flushing. The results of standard cardiovascular autonomic tests showed no evidence of autonomic dysfunction in any of the enrolled patients. At spectral analysis, a residual baroreflex performance was shown in both patient groups, though reduced, as expected, compared to young controls. Notably, baroreflex function was better maintained in e-CEA, compared to standard CEA. (BRS at rest: young controls 19.93 ± 2.45 msec/mmHg; age-matched controls 7.75 ± 1.24; e-CEA 13.85 ± 5.14; s-CEA 4.93 ± 1.15; ANOVA P=0.001; BRS at stand: young controls 7.83 ± 0.66; age-matched controls 3.71 ± 0.35; e-CEA 7.04 ± 1.99; s-CEA 3.57 ± 1.20; ANOVA P=0.001). In all subjects ventilation (VÝ E) and oximetry data fitted a linear regression model with r values > 0.8. Oneway analysis of variance showed a significantly higher slope both for ΔVE/ΔSaO2 in controls compared with both patient groups which were not different from each other (-1.37 ± 0.33 compared with -0.33±0.08 and -0.29 ±0.13 l/min/%SaO2, p<0.05, Fig.). Similar results were observed for and ΔVE/ΔPetO2 (-0.20 ± 0.1 versus -0.01 ± 0.0 and -0.07 ± 0.02 l/min/mmHg, p<0.05). A regression model using treatment, age, baseline FiCO2 and minimum SaO2 achieved showed only treatment as a significant factor in explaining the variance in minute ventilation (R2= 25%). Conclusions Overall, we demonstrated that bilateral e-CEA does not imply a carotid sinus denervation. As a result of some expected degree of iatrogenic damage, such performance was lower than that of controls. Interestingly though, baroreflex performance appeared better maintained in e-CEA than in s-CEA. This may be related to the changes in the elastic properties of the carotid sinus vascular wall, as the patch is more rigid than the endarterectomized carotid wall that remains in the e-CEA. These data confirmed the safety of CEA irrespective of the surgical technique and have relevant clinical implication in the assessment of the frequent hemodynamic disturbances associated with carotid angioplasty stenting.
Resumo:
IL-33/ST2 axis is known to promote Th2 immune responses and has been linked to several autoimmune and inflammatory disorders, including inflammatory bowel disease (IBD), and recent evidences show that it can regulate eosinophils (EOS) infiltration and function. Based also on the well documented relationship between EOS and IBD, we assessed the role of IL-33-mediated eosinophilia and ileal inflammation in SAMP1/YitFc (SAMP) murine model of Th1/Th2 chronic enteritis, and we found that IL-33 is related to inflammation progression and EOS infiltration as well as IL-5 and eotaxins increase. Administering IL-33 to SAMP and AKR mice augmented eosinophilia, eotaxins mRNA expression and Th2 molecules production, whereas blockade of ST2 and/or typical EOS molecules, such as IL-5 and CCR3, resulted in a marked decrease of inflammation, EOS infiltration, IL-5 and eotaxins mRNA expression and Th2 cytokines production. Human data supported mice’s showing an increased colocalization of IL-33 and EOS in the colon mucosa of UC patients, as well as an augmented IL-5 and eotaxins mRNA expression, when compared to non-UC. Lastly we analyzed SAMP raised in germ free (GF) condition to see the microbiota effect on IL-33 expression and Th2 responses leading to chronic intestinal inflammation. We found a remarkable decrease in ileal IL-33 and Th2 cytokines mRNA expression as well as EOS infiltration in GF versus normal SAMP with comparable inflammatory scores. Moreover, EOS depletion in normal SAMP didn’t affect IL-33 mRNA expression. These data demonstrate a pathogenic role of IL-33-mediated eosinophilia in chronic intestinal inflammation, and that blockade of IL-33 and/or downstream EOS activation may represent a novel therapeutic modality to treat patients with IBD. Also they highlight the gut microbiota role in IL-33 production, and the following EOS infiltration in the intestinal mucosa, confirming that the microbiota is essential in mounting potent Th2 response leading to chronic ileitis in SAMP.
Resumo:
Hair cortisol is a novel marker to measure long-term secretion cortisol free from many methodological caveats associated with other matrices such as plasma, saliva, urine, milk and faeces. For decades hair analysis has been successfully used in forensic science and toxicology to evaluate the exposure to exogenous substances and assess endogenous steroid hormones. Evaluation of cortisol in hair matrix began about a decade ago and have over the past five years had a remarkable development by advancing knowledge and affirming this method as a new and efficient way to study the hypothalamic-pituitary-adrenal (HPA) axis activity over a long time period. In farm animals, certain environmental or management conditions can potentially activate the HPA axis. Given the importance of cortisol in monitoring the HPA axis activity, a first approach has involved the study on the distribution of hair cortisol concentrations (HCC) in healthy dairy cows showing a physiological range of variation of this hormone. Moreover, HCC have been significantly influenced also by changes in environmental conditions and a significant positive correlation was detected between HCC and cows clinically or physiologically compromised suggesting that these cows were subjected to repeated HPA axis activation. Additionally, Crossbreed F1 heifers showed significantly lower HCC compared to pure animals and a breed influence has been seen also on the HPA axis activity stimulated by an environmental change showing thus a higher level of resilience and a better adaptability to the environment of certain genotypes. Hair proved to be an excellent matrix also in the study of the activation of the HPA axis during the perinatal period. The use of hair analysis in research holds great promise to significantly enhance current understanding on the role of HPA axis over a long period of time.
Resumo:
The evaluation of chronic activity of the hypothalamic-pituitary-adrenal (HPA) axis is critical for determining the impact of chronic stressful situations. The potential use of hair glucocorticoids as a non-invasive, retrospective, biomarker of long term HPA activity is of great interest, and it is gaining acceptance in humans and animals. However, there are still no studies in literature examining hair cortisol concentration in pigs and corticosterone concentration in laboratory rodents. Therefore, we developed and validated, for the first time, a method for measuring hair glucocorticoids concentration in commercial sows and in Sprague-Dawley rats. Our preliminary data demonstrated: 1) a validated and specific washing protocol and extraction assay method with a good sensitivity in both species; 2) the effect of the reproductive phase, housing conditions and seasonality on hair cortisol concentration in sows; 3) similar hair corticosterone concentration in male and female rats; 4) elevated hair corticosterone concentration in response to chronic stress manipulations and chronic ACTH administration, demonstrating that hair provides a good direct index of HPA activity over long periods than other indirect parameters, such adrenal or thymus weight. From these results we believe that this new non-invasive tool needs to be applied to better characterize the overall impact in livestock animals and in laboratory rodents of chronic stressful situations that negatively affect animals welfare. Nevertheless, further studies are needed to improve this methodology and maybe to develop animal models for chronic stress of high interest and translational value in human medicine.
Resumo:
In the first part of the thesis, we propose an exactly-solvable one-dimensional model for fermions with long-range p-wave pairing decaying with distance as a power law. We studied the phase diagram by analyzing the critical lines, the decay of correlation functions and the scaling of the von Neumann entropy with the system size. We found two gapped regimes, where correlation functions decay (i) exponentially at short range and algebraically at long range, (ii) purely algebraically. In the latter the entanglement entropy is found to diverge logarithmically. Most interestingly, along the critical lines, long-range pairing breaks also the conformal symmetry. This can be detected via the dynamics of entanglement following a quench. In the second part of the thesis we studied the evolution in time of the entanglement entropy for the Ising model in a transverse field varying linearly in time with different velocities. We found different regimes: an adiabatic one (small velocities) when the system evolves according the instantaneous ground state; a sudden quench (large velocities) when the system is essentially frozen to its initial state; and an intermediate one, where the entropy starts growing linearly but then displays oscillations (also as a function of the velocity). Finally, we discussed the Kibble-Zurek mechanism for the transition between the paramagnetic and the ordered phase.
Resumo:
Over the past ten years, the cross-correlation of long-time series of ambient seismic noise (ASN) has been widely adopted to extract the surface-wave part of the Green’s Functions (GF). This stochastic procedure relies on the assumption that ASN wave-field is diffuse and stationary. At frequencies <1Hz, the ASN is mainly composed by surface-waves, whose origin is attributed to the sea-wave climate. Consequently, marked directional properties may be observed, which call for accurate investigation about location and temporal evolution of the ASN-sources before attempting any GF retrieval. Within this general context, this thesis is aimed at a thorough investigation about feasibility and robustness of the noise-based methods toward the imaging of complex geological structures at the local (∼10-50km) scale. The study focused on the analysis of an extended (11 months) seismological data set collected at the Larderello-Travale geothermal field (Italy), an area for which the underground geological structures are well-constrained thanks to decades of geothermal exploration. Focusing on the secondary microseism band (SM;f>0.1Hz), I first investigate the spectral features and the kinematic properties of the noise wavefield using beamforming analysis, highlighting a marked variability with time and frequency. For the 0.1-0.3Hz frequency band and during Spring- Summer-time, the SMs waves propagate with high apparent velocities and from well-defined directions, likely associated with ocean-storms in the south- ern hemisphere. Conversely, at frequencies >0.3Hz the distribution of back- azimuths is more scattered, thus indicating that this frequency-band is the most appropriate for the application of stochastic techniques. For this latter frequency interval, I tested two correlation-based methods, acting in the time (NCF) and frequency (modified-SPAC) domains, respectively yielding esti- mates of the group- and phase-velocity dispersions. Velocity data provided by the two methods are markedly discordant; comparison with independent geological and geophysical constraints suggests that NCF results are more robust and reliable.
Resumo:
Long air gaps containing a floating conductor are common insulation types in power grids. During the transmission line live-line work, the process of lineman entering the transmission line air gap constitutes a live-line work combined air gap, which is a typical long air gap containing a floating conductor. This thesis investigates the discharge characteristics, the discharge mechanism and a discharge simulation model of long air gaps containing a floating conductor in order to address the engineering issues in live-line work. The innovative achievements of the thesis are as follows: (1) The effect of the gap distance, the floating electrode structure, the switching impulse wavefront time, the altitude, and the deviation of the floating conductor from the axis on the breakdown voltage was determined. (2) The physical process of the discharges in long air gaps containing a floating conductor was determined. The reason why the discharge characteristics of long air gaps containing a floating electrode with complex geometrics and sharp protrusions and long air gaps with a rod-shaped floating electrode are similar has been studied. The formation mechanism of the lowest breakdown voltage area of a long air gap containing a floating conductor is explained. (3) A simulation discharge model of long air gaps containing a floating conductor was established, which can describe the physical process and predict the breakdown voltage. The model can realize the accurate prediction of the breakdown voltage of typical long air gaps containing a floating conductor and live-line work combined air gaps in transmission lines. The findings of the study can provide theoretical reference and technical support for improving the safety of live-line work.
Resumo:
Introduction The maternal vasculature undergoes significant adaptations during pregnancy to meet the increased metabolic demands of the developing fetus. These adaptations include increased cardiac output and blood volume, as well as reduced systemic vascular resistance. In Hypertensive disorders of pregnancy (HDP) there is an impaired cardiovascular adaptation to pregnancy with effects extending beyond pregnancy. In the present study we aimed to characterize long-term cardiovascular status of women who suffered from HDP. Methods Fifty-eight women who attended at least one post-partum visit and a follow-up visit after at least 5 years from delivery were enrolled in the study. Exclusion criteria included multiple pregnancy, fetal genetic or congenital abnormalities, maternal history of organ transplantation, or chronic renal failure (eGFR≤45ml/min/1.73m2). In the follow-up visit participants underwent a complete cardiovascular assessment including echocardiography and multiparametric vascular function assessment. Results and Discussion Two major cardiovascular events, one stroke and one myocardial infarction, occurred both in women with index-pregnancy complicated by preeclampsia (PE). While not statistically significant, women with HDP-non-PE and PE displayed a trend towards an increased risk of developing composite cardiovascular outcome, and women with PE tended to experience it sooner. Nearly half of the women with a history of HDP, whether PE or HDP-non-PE, developed chronic hypertension. Some women also developed hyperuricemia, chronic kidney disease (CKD), and type 2 diabetes at follow- up, most of them had a previous history of PE. Structural and functional cardiac changes were observed in a few cases, especially among women with PE, and vascular dysfunction was more common in women with a history of HDP compared to those with normotensive pregnancies. Results of the present study adds on literature on long-term cardiovascular impact of HDP and further emphasize the importance of a timely follow-up of women who suffered from HDP and particularly PE.