45 resultados para Kinematic

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a non linear technique to invert strong motion records with the aim of obtaining the final slip and rupture velocity distributions on the fault plane. In this thesis, the ground motion simulation is obtained evaluating the representation integral in the frequency. The Green’s tractions are computed using the discrete wave-number integration technique that provides the full wave-field in a 1D layered propagation medium. The representation integral is computed through a finite elements technique, based on a Delaunay’s triangulation on the fault plane. The rupture velocity is defined on a coarser regular grid and rupture times are computed by integration of the eikonal equation. For the inversion, the slip distribution is parameterized by 2D overlapping Gaussian functions, which can easily relate the spectrum of the possible solutions with the minimum resolvable wavelength, related to source-station distribution and data processing. The inverse problem is solved by a two-step procedure aimed at separating the computation of the rupture velocity from the evaluation of the slip distribution, the latter being a linear problem, when the rupture velocity is fixed. The non-linear step is solved by optimization of an L2 misfit function between synthetic and real seismograms, and solution is searched by the use of the Neighbourhood Algorithm. The conjugate gradient method is used to solve the linear step instead. The developed methodology has been applied to the M7.2, Iwate Nairiku Miyagi, Japan, earthquake. The estimated magnitude seismic moment is 2.6326 dyne∙cm that corresponds to a moment magnitude MW 6.9 while the mean the rupture velocity is 2.0 km/s. A large slip patch extends from the hypocenter to the southern shallow part of the fault plane. A second relatively large slip patch is found in the northern shallow part. Finally, we gave a quantitative estimation of errors associates with the parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During my PhD, starting from the original formulations proposed by Bertrand et al., 2000 and Emolo & Zollo 2005, I developed inversion methods and applied then at different earthquakes. In particular large efforts have been devoted to the study of the model resolution and to the estimation of the model parameter errors. To study the source kinematic characteristics of the Christchurch earthquake we performed a joint inversion of strong-motion, GPS and InSAR data using a non-linear inversion method. Considering the complexity highlighted by superficial deformation data, we adopted a fault model consisting of two partially overlapping segments, with dimensions 15x11 and 7x7 km2, having different faulting styles. This two-fault model allows to better reconstruct the complex shape of the superficial deformation data. The total seismic moment resulting from the joint inversion is 3.0x1025 dyne.cm (Mw = 6.2) with an average rupture velocity of 2.0 km/s. Errors associated with the kinematic model have been estimated of around 20-30 %. The 2009 Aquila sequence was characterized by an intense aftershocks sequence that lasted several months. In this study we applied an inversion method that assumes as data the apparent Source Time Functions (aSTFs), to a Mw 4.0 aftershock of the Aquila sequence. The estimation of aSTFs was obtained using the deconvolution method proposed by Vallée et al., 2004. The inversion results show a heterogeneous slip distribution, characterized by two main slip patches located NW of the hypocenter, and a variable rupture velocity distribution (mean value of 2.5 km/s), showing a rupture front acceleration in between the two high slip zones. Errors of about 20% characterize the final estimated parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Restoring a correct implant kinematics and providing a good ligament balance and patellar tracking is mandatory to improve clinical and functional outcome after a Total Knee Replacement. Surgical navigation systems are a reliable and accurate tool to help the surgeon in achieving these goals. The aim of the present study was to use navigation system with an intra-operative surgical protocol to evaluate and determine an optimal implant kinematics during a Total Knee Replacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have used kinematic models in two Italian regions to reproduce surface interseismic velocities obtained from InSAR and GPS measurements. We have considered a Block modeling, BM, approach to evaluate which fault system is actively accommodating the occurring deformation in both considered areas. We have performed a study for the Umbria-Marche Apennines, obtaining that the tectonic extension observed by GPS measurements is explained by the active contribution of at least two fault systems, one of which is the Alto Tiberina fault, ATF. We have estimated also the interseismic coupling distribution for the ATF using a 3D surface and the result shows an interesting correlation between the microseismicity and the uncoupled fault portions. The second area analyzed concerns the Gargano promontory for which we have used jointly the available InSAR and GPS velocities. Firstly we have attached the two datasets to the same terrestrial reference frame and then using a simple dislocation approach, we have estimated the best fault parameters reproducing the available data, providing a solution corresponding to the Mattinata fault. Subsequently we have considered within a BM analysis both GPS and InSAR datasets in order to evaluate if the Mattinata fault may accommodate the deformation occurring in the central Adriatic due to the relative motion between the North-Adriatic and South-Adriatic plates. We obtain that the deformation occurring in that region should be accommodated by more that one fault system, that is however difficult to detect since the poor coverage of geodetic measurement offshore of the Gargano promontory. Finally we have performed also the estimate of the interseismic coupling distribution for the Mattinata fault, obtaining a shallow coupling pattern. Both of coupling distributions found using the BM approach have been tested by means of resolution checkerboard tests and they demonstrate that the coupling patterns depend on the geodetic data positions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of tendons for the transmission of the forces and the movements in robotic devices has been investigated from several researchers all over the world. The interest in this kind of actuation modality is based on the possibility of optimizing the position of the actuators with respect to the moving part of the robot, in the reduced weight, high reliability, simplicity in the mechanic design and, finally, in the reduced cost of the resulting kinematic chain. After a brief discussion about the benefits that the use of tendons can introduce in the motion control of a robotic device, the design and control aspects of the UB Hand 3 anthropomorphic robotic hand are presented. In particular, the tendon-sheaths transmission system adopted in the UB Hand 3 is analyzed and the problem of force control and friction compensation is taken into account. The implementation of a tendon based antagonistic actuated robotic arm is then investigated. With this kind of actuation modality, and by using transmission elements with nonlinear force/compression characteristic, it is possible to achieve simultaneous stiffness and position control, improving in this way the safety of the device during the operation in unknown environments and in the case of interaction with other robots or with humans. The problem of modeling and control of this type of robotic devices is then considered and the stability analysis of proposed controller is reported. At the end, some tools for the realtime simulation of dynamic systems are presented. This realtime simulation environment has been developed with the aim of improving the reliability of the realtime control applications both for rapid prototyping of controllers and as teaching tools for the automatic control courses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Motion control is a sub-field of automation, in which the position and/or velocity of machines are controlled using some type of device. In motion control the position, velocity, force, pressure, etc., profiles are designed in such a way that the different mechanical parts work as an harmonious whole in which a perfect synchronization must be achieved. The real-time exchange of information in the distributed system that is nowadays an industrial plant plays an important role in order to achieve always better performance, better effectiveness and better safety. The network for connecting field devices such as sensors, actuators, field controllers such as PLCs, regulators, drive controller etc., and man-machine interfaces is commonly called fieldbus. Since the motion transmission is now task of the communication system, and not more of kinematic chains as in the past, the communication protocol must assure that the desired profiles, and their properties, are correctly transmitted to the axes then reproduced or else the synchronization among the different parts is lost with all the resulting consequences. In this thesis, the problem of trajectory reconstruction in the case of an event-triggered communication system is faced. The most important feature that a real-time communication system must have is the preservation of the following temporal and spatial properties: absolute temporal consistency, relative temporal consistency, spatial consistency. Starting from the basic system composed by one master and one slave and passing through systems made up by many slaves and one master or many masters and one slave, the problems in the profile reconstruction and temporal properties preservation, and subsequently the synchronization of different profiles in network adopting an event-triggered communication system, have been shown. These networks are characterized by the fact that a common knowledge of the global time is not available. Therefore they are non-deterministic networks. Each topology is analyzed and the proposed solution based on phase-locked loops adopted for the basic master-slave case has been improved to face with the other configurations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis comes after a strong contribution on the realization of the CMS computing system, which can be seen as a relevant part of the experiment itself. A physics analysis completes the road from Monte Carlo production and analysis tools realization to the final physics study which is the actual goal of the experiment. The topic of physics work of this thesis is the study of tt events fully hadronic decay in the CMS experiment. A multi-jet trigger has been provided to fix a reasonable starting point, reducing the multi-jet sample to the nominal trigger rate. An offline selection has been provided to reduce the S/B ratio. The b-tag is applied to provide a further S/B improvement. The selection is applied to the background sample and to the samples generated at different top quark masses. The top quark mass candidate is reconstructed for all those samples using a kinematic fitter. The resulting distributions are used to build p.d.f.’s, interpolating them with a continuous arbitrary curve. These curves are used to perform the top mass measurement through a likelihood comparison

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ren and colleagues (2006) found that saccades to visual targets became less accurate when somatosensory information about hand location was added, suggesting that saccades rely mainly on vision. We conducted two kinematic experiments to examine whether or not reaching movements would also show such strong reliance on vision. In Experiment 1, subjects used their dominant right hand to perform reaches, with or without a delay, to an external visual target or to their own left fingertip positioned either by the experimenter or by the participant. Unlike saccades, reaches became more accurate and precise when proprioceptive information was available. In Experiment 2, subjects reached toward external or bodily targets with differing amounts of visual information. Proprioception improved performance only when vision was limited. Our results indicate that reaching movements, unlike saccades, are improved rather than impaired by the addition of somatosensory information.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

(U-Th)/He and fission-track analyses of apatite along deep-seated tunnels crossing high-relief mountain ranges offer the opportunity to investigate climate and tectonic forcing on the topographic evolution. In this study, the thermochronologic analysis of a large set of samples collected in the Simplon railway tunnel (western-central Alps; Italy and Switzerland) and along its surface trace, coupled with kinematic and structural analysis of major fault zones intersecting the tunnel, constrains the phenomena controlling the topographic and structural evolution, during the latest stage of exhumation of the Simplon Massif, and the timing in which they operated. The study area is located at the western margin of the Lepontine metamorphic dome where a complex nappe-stack pertaining to the Penninic and Ultrahelvetic domains experienced a fast exhumation from the latest Oligocene onward. The exhumation was mainly accommodated by a west-dipping low-angle detachment (the Simplon Fault Zone) which is located just 8 km to the west of the tunnel. However, along the section itself several faults related to two principal phases both with important dip-slip kinematics have been detected. Cooling rates derived from our thermocronological data vary from about 10 °C/Ma at about 10 Ma to about 35 °C/Ma in the last 5 Ma. Such increase in the cooling rate corresponds to the most important climatic change recorded in the northern hemisphere in the last 10 Ma, i.e. the shift to wetter conditions at the end of the Messinian salinity crisis and the inception of glacial cycles in the northern hemisphere. In addition, (U-Th)/He and fission-track age patterns lack of important correlation with the topography suggesting that the present-day relief morphology is the result of recent erosional dynamics. More in details, the (U-Th)/He tunnel ages show an impressive uniformity at 2 Ma, whereas cooling rates calculated at 1 Ma increase towards the two major valleys. This indicates a focusing of erosive processes in the valleys which led to the shaping of present-day topography. Structural analysis documents the presence of two phases of brittle deformation postdating the metamorphic phases in the area. The first one is directly related to the last phase of activity along the Simplon Fault Zone and is characterized by extension towards SO and vertical shortening. The young one is characterized by extension towards NO and horizontal shortening in a along the NE-SO direction. Structures related to the first phase of brittle deformation generate important variations in the older ages' dataset, until 3 Ma, suggesting that tectonics controlled rocks exhumation up to that age. Structures related to the second phase generate some variations also in the younger age dataset, highlighting the activity of faults bordering the massif and suggesting a continuous activity also after 2 Ma. However, most of (U-Th)/He tunnel ages, varying slightly around 2 Ma, document that the Simplon area has experienced primarily erosional exhumation in this time span. In conclusion, all our data suggest that in the central Italian Alps the climatic signal gradually overrode the tectonic effects after about 5 Ma, as a consequence of the climatic instability started at end of Messinian salinity crisis and improved by the onset of glaciations in the northern hemisphere.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Knowledge on how ligaments and articular surfaces guide passive motion at the human ankle joint complex is fundamental for the design of relevant surgical treatments. The dissertation presents a possible improvement of this knowledge by a new kinematic model of the tibiotalar articulation. In this dissertation two one-DOF spatial equivalent mechanisms are presented for the simulation of the passive motion of the human ankle joint: the 5-5 fully parallel mechanism and the fully parallel spherical wrist mechanism. These mechanisms are based on the main anatomical structures of the ankle joint, namely the talus/calcaneus and the tibio/fibula bones at their interface, and the TiCaL and CaFiL ligaments. In order to show the accuracy of the models and the efficiency of the proposed procedure, these mechanisms are synthesized from experimental data and the results are compared with those obtained both during experimental sessions and with data published in the literature. Experimental results proved the efficiency of the proposed new mechanisms to simulate the ankle passive motion and, at the same time, the potentiality of the mechanism to replicate the ankle’s main anatomical structures quite well. The new mechanisms represent a powerful tool for both pre-operation planning and new prosthesis design.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Curved mountain belts have always fascinated geologists and geophysicists because of their peculiar structural setting and geodynamic mechanisms of formation. The need of studying orogenic bends arises from the numerous questions to which geologists and geophysicists have tried to answer to during the last two decades, such as: what are the mechanisms governing orogenic bends formation? Why do they form? Do they develop in particular geological conditions? And if so, what are the most favorable conditions? What are their relationships with the deformational history of the belt? Why is the shape of arcuate orogens in many parts of the Earth so different? What are the factors controlling the shape of orogenic bends? Paleomagnetism demonstrated to be one of the most effective techniques in order to document the deformation of a curved belt through the determination of vertical axis rotations. In fact, the pattern of rotations within a curved belt can reveal the occurrence of a bending, and its timing. Nevertheless, paleomagnetic data alone are not sufficient to constrain the tectonic evolution of a curved belt. Usually, structural analysis integrates paleomagnetic data, in defining the kinematics of a belt through kinematic indicators on brittle fault planes (i.e., slickensides, mineral fibers growth, SC-structures). My research program has been focused on the study of curved mountain belts through paleomagnetism, in order to define their kinematics, timing, and mechanisms of formation. Structural analysis, performed only in some regions, supported and integrated paleomagnetic data. In particular, three arcuate orogenic systems have been investigated: the Western Alpine Arc (NW Italy), the Bolivian Orocline (Central Andes, NW Argentina), and the Patagonian Orocline (Tierra del Fuego, southern Argentina). The bending of the Western Alpine Arc has been investigated so far using different approaches, though few based on reliable paleomagnetic data. Results from our paleomagnetic study carried out in the Tertiary Piedmont Basin, located on top of Alpine nappes, indicate that the Western Alpine Arc is a primary bend that has been subsequently tightened by further ~50° during Aquitanian-Serravallian times (23-12 Ma). This mid-Miocene oroclinal bending, superimposing onto a pre-existing Eocene nonrotational arc, is the result of a composite geodynamic mechanism, where slab rollback, mantle flows, and rotating thrust emplacement are intimately linked. Relying on our paleomagnetic and structural evidence, the Bolivian Orocline can be considered as a progressive bend, whose formation has been driven by the along-strike gradient of crustal shortening. The documented clockwise rotations up to 45° are compatible with a secondary-bending type mechanism occurring after Eocene-Oligocene times (30-40 Ma), and their nature is probably related to the widespread shearing taking place between zones of differential shortening. Since ~15 Ma ago, the activity of N-S left-lateral strike-slip faults in the Eastern Cordillera at the border with the Altiplano-Puna plateau induced up to ~40° counterclockwise rotations along the fault zone, locally annulling the regional clockwise rotation. We proposed that mid-Miocene strike-slip activity developed in response of a compressive stress (related to body forces) at the plateau margins, caused by the progressive lateral (southward) growth of the Altiplano-Puna plateau, laterally spreading from the overthickened crustal region of the salient apex. The growth of plateaux by lateral spreading seems to be a mechanism common to other major plateaux in the Earth (i.e., Tibetan plateau). Results from the Patagonian Orocline represent the first reliable constraint to the timing of bending in the southern tip of South America. They indicate that the Patagonian Orocline did not undergo any significant rotation since early Eocene times (~50 Ma), implying that it may be considered either a primary bend, or an orocline formed during the late Cretaceous-early Eocene deformation phase. This result has important implications on the opening of the Drake Passage at ~32 Ma, since it is definitely not related to the formation of the Patagonian orocline, but the sole consequence of the Scotia plate spreading. Finally, relying on the results and implications from the study of the Western Alpine Arc, the Bolivian Orocline, and the Patagonian Orocline, general conclusions on curved mountain belt formation have been inferred.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Human reactions to vibration have been extensively investigated in the past. Vibration, as well as whole-body vibration (WBV), has been commonly considered as an occupational hazard for its detrimental effects on human condition and comfort. Although long term exposure to vibrations may produce undesirable side-effects, a great part of the literature is dedicated to the positive effects of WBV when used as method for muscular stimulation and as an exercise intervention. Whole body vibration training (WBVT) aims to mechanically activate muscles by eliciting neuromuscular activity (muscle reflexes) via the use of vibrations delivered to the whole body. The most mentioned mechanism to explain the neuromuscular outcomes of vibration is the elicited neuromuscular activation. Local tendon vibrations induce activity of the muscle spindle Ia fibers, mediated by monosynaptic and polysynaptic pathways: a reflex muscle contraction known as the Tonic Vibration Reflex (TVR) arises in response to such vibratory stimulus. In WBVT mechanical vibrations, in a range from 10 to 80 Hz and peak to peak displacements from 1 to 10 mm, are usually transmitted to the patient body by the use of oscillating platforms. Vibrations are then transferred from the platform to a specific muscle group through the subject body. To customize WBV treatments, surface electromyography (SEMG) signals are often used to reveal the best stimulation frequency for each subject. Use of SEMG concise parameters, such as root mean square values of the recordings, is also a common practice; frequently a preliminary session can take place in order to discover the more appropriate stimulation frequency. Soft tissues act as wobbling masses vibrating in a damped manner in response to mechanical excitation; Muscle Tuning hypothesis suggest that neuromuscular system works to damp the soft tissue oscillation that occurs in response to vibrations; muscles alters their activity to dampen the vibrations, preventing any resonance phenomenon. Muscle response to vibration is however a complex phenomenon as it depends on different parameters, like muscle-tension, muscle or segment-stiffness, amplitude and frequency of the mechanical vibration. Additionally, while in the TVR study the applied vibratory stimulus and the muscle conditions are completely characterised (a known vibration source is applied directly to a stretched/shortened muscle or tendon), in WBV study only the stimulus applied to a distal part of the body is known. Moreover, mechanical response changes in relation to the posture. The transmissibility of vibratory stimulus along the body segment strongly depends on the position held by the subject. The aim of this work was the investigation on the effects that the use of vibrations, in particular the effects of whole body vibrations, may have on muscular activity. A new approach to discover the more appropriate stimulus frequency, by the use of accelerometers, was also explored. Different subjects, not affected by any known neurological or musculoskeletal disorders, were voluntarily involved in the study and gave their informed, written consent to participate. The device used to deliver vibration to the subjects was a vibrating platform. Vibrations impressed by the platform were exclusively vertical; platform displacement was sinusoidal with an intensity (peak-to-peak displacement) set to 1.2 mm and with a frequency ranging from 10 to 80 Hz. All the subjects familiarized with the device and the proper positioning. Two different posture were explored in this study: position 1 - hack squat; position 2 - subject standing on toes with heels raised. SEMG signals from the Rectus Femoris (RF), Vastus Lateralis (VL) and Vastus medialis (VM) were recorded. SEMG signals were amplified using a multi-channel, isolated biomedical signal amplifier The gain was set to 1000 V/V and a band pass filter (-3dB frequency 10 - 500 Hz) was applied; no notch filters were used to suppress line interference. Tiny and lightweight (less than 10 g) three-axial MEMS accelerometers (Freescale semiconductors) were used to measure accelerations of onto patient’s skin, at EMG electrodes level. Accelerations signals provided information related to individuals’ RF, Biceps Femoris (BF) and Gastrocnemius Lateralis (GL) muscle belly oscillation; they were pre-processed in order to exclude influence of gravity. As demonstrated by our results, vibrations generate peculiar, not negligible motion artifact on skin electrodes. Artifact amplitude is generally unpredictable; it appeared in all the quadriceps muscles analysed, but in different amounts. Artifact harmonics extend throughout the EMG spectrum, making classic high-pass filters ineffective; however, their contribution was easy to filter out from the raw EMG signal with a series of sharp notch filters centred at the vibration frequency and its superior harmonics (1.5 Hz wide). However, use of these simple filters prevents the revelation of EMG power potential variation in the mentioned filtered bands. Moreover our experience suggests that the possibility of reducing motion artefact, by using particular electrodes and by accurately preparing the subject’s skin, is not easily viable; even though some small improvements were obtained, it was not possible to substantially decrease the artifact. Anyway, getting rid of those artifacts lead to some true EMG signal loss. Nevertheless, our preliminary results suggest that the use of notch filters at vibration frequency and its harmonics is suitable for motion artifacts filtering. In RF SEMG recordings during vibratory stimulation only a little EMG power increment should be contained in the mentioned filtered bands due to synchronous electromyographic activity of the muscle. Moreover, it is better to remove the artifact that, in our experience, was found to be more than 40% of the total signal power. In summary, many variables have to be taken into account: in addition to amplitude, frequency and duration of vibration treatment, other fundamental variables were found to be subject anatomy, individual physiological condition and subject’s positioning on the platform. Studies on WBV treatments that include surface EMG analysis to asses muscular activity during vibratory stimulation should take into account the presence of motion artifacts. Appropriate filtering of artifacts, to reveal the actual effect on muscle contraction elicited by vibration stimulus, is mandatory. However as a result of our preliminary study, a simple multi-band notch filtering may help to reduce randomness of the results. Muscle tuning hypothesis seemed to be confirmed. Our results suggested that the effects of WBV are linked to the actual muscle motion (displacement). The greater was the muscle belly displacement the higher was found the muscle activity. The maximum muscle activity has been found in correspondence with the local mechanical resonance, suggesting a more effective stimulation at the specific system resonance frequency. Holding the hypothesis that muscle activation is proportional to muscle displacement, treatment optimization could be obtained by simply monitoring local acceleration (resonance). However, our study revealed some short term effects of vibratory stimulus; prolonged studies should be assembled in order to consider the long term effectiveness of these results. Since local stimulus depends on the kinematic chain involved, WBV muscle stimulation has to take into account the transmissibility of the stimulus along the body segment in order to ensure that vibratory stimulation effectively reaches the target muscle. Combination of local resonance and muscle response should also be further investigated to prevent hazards to individuals undergoing WBV treatments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Urbanization is a continuing phenomenon in all the world. Grasslands, forests, etc. are being continually changed to residential, commercial and industrial complexes, roads and streets, and so on. One of the side effects of urbanization with which engineers and planners must deal with, is the increase of peak flows and volumes of runoff from rainfall events. As a result, the urban drainage and flood control systems must be designed to accommodate the peak flows from a variety of storms that may occur. Usually the peak flow, after development, is required not to exceed what would have occurred from the same storm under conditions existing prior to development. In order to do this it is necessary to design detention storage to hold back runoff and to release it downstream at controlled rates. In the first part of the work have been developed various simplified formulations that can be adopted for the design of stormwater detention facilities. In order to obtain a simplified hydrograph were adopted two approaches: the kinematic routing technique and the linear reservoir schematization. For the two approaches have been also obtained other two formulations depending if the IDF (intensity-duration-frequency) curve is described with two or three parameters. Other formulations have been developed taking into account if the outlet have a constant discharge or it depends on the water level in the pond. All these formulations can be easily applied when are known the characteristics of the drainage system and maximum discharge that these is in the outlet and has been defined a Return Period which characterize the IDF curve. In this way the volume of the detention pond can be calculated. In the second part of the work have been analyzed the design of detention ponds adopting continuous simulation models. The drainage systems adopted for the simulations, performed with SWMM5, are fictitious systems characterized by different sizes, and different shapes of the catchments and with a rainfall historical time series of 16 years recorded in Bologna. This approach suffers from the fact that continuous record of rainfall is often not available and when it is, the cost of such modelling can be very expensive, and that the majority of design practitioners are not prepared to use continuous long term modelling in the design of stormwater detention facilities. In the third part of the work have been analyzed statistical and stochastic methodologies in order to define the volume of the detention pond. In particular have been adopted the results of the long term simulation, performed with SWMM, to obtain the data to apply statistic and stochastic formulation. All these methodologies have been compared and correction coefficient have been proposed on the basis of the statistic and stochastic form. In this way engineers which have to design a detention pond can apply a simplified procedure appropriately corrected with the proposed coefficient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L'attività di ricerca descritta in questa tesi fornisce linee guida per la progettazione di arti protesici inferiori, con particolare riferimento alla progettazione di protesi a basso costo. La necessità di efficienti protesi a basso costo risulta infatti sentita nei Paesi in via di sviluppo ma anche dalle fasce meno abbienti dei paesi occidentali. Al fine di comprendere le strategie adottate dall'apparato locomotorio per muoversi con le protesi sono analizzati il cammino fisiologico, le protesi presenti sul mercato ed infine le modalità con cui le loro prestazioni sono valutate. Con il presente lavoro, dopo aver osservato la presenza di una scarsa strutturazione della metodologia di progettazione che riguarda specialmente il settore del basso costo, si propone una metodologia il più possibile oggettiva e ripetibile tesa ad individuare quali sono gli aspetti essenziali di una protesi per garantire al paziente una buona qualità di vita. Solo questi aspetti dovranno essere selezionati al fine di ottenere la massima semplificazione della protesi e ridurre il più possibile i costi. Per la simulazione delle attività di locomozione, in particolare del cammino, è stato elaborato un apposito modello spaziale del cammino. Il modello proposto ha 7 membri rigidi (corrispondenti a piedi, tibie, femori e bacino) e 24 gradi di libertà. Le articolazioni e l'appoggio dei piedi al suolo sono modellati con giunti sferici. La pianta del piede consente tre possibili punti di appoggio. I criteri di realizzazione delle simulazioni possono comprendere aspetti energetici, cinematici e dinamici considerati come obiettivo dall'apparato locomotorio. In questa tesi vengono trattati in particolare gli aspetti cinematici ed è mostrata un'applicazione della procedura nella quale vengono dapprima identificati i riferimenti fisiologici del cammino e quindi simulato il cammino in presenza di una menomazione al ginocchio (eliminazione della flessione in fase di appoggio). Viene quindi lasciato a sviluppi futuri il completamento della procedura e la sua implementazione in un codice di calcolo.